Product Attributes:
Type: Circuit Breaker
High Voltage Circuit Breakers
Operation: Electric Type
Normal Type Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Fixed
Poles Number: 3
Conventional Circuit Breaker
Certification: ISO9001-2000
Structure: ACB
Shell Material: Stainless Steel
Voltage Level: Medium Voltage
Current: AC
Application: Power
Phase: Three
Core: Core-type Transformer
Winding Type: Auto-transformer
Usage: Rectifier Transformer
Frequency Characteristics: High Frequency
Shape of Core: OD
Operation: Energy-storage Type
Operation: Manual Type
High-Speed Circuit Breaker
Arc-extinguishing Medium: Air
Arc-extinguishing Medium: SF6
Installation: Open Frame
Poles Number: 1
Circuit-Breaker Failure Protection
Function: Overcurrent Protection
Function: OVP(Overvoltage Protection)
Function: RCCB
Certification: VDE
Certification: CE
Certification: CB
Certification: CCC
Certification: ISO9001
Structure: MCCB
Structure: Cabinet
Application: Electronic
Application: Rectifier

Sourcing guidance for Circuit Breaker Auto Recloser

What are the key technical specifications to consider when selecting a Circuit Breaker Auto Recloser?

When sourcing auto reclosers, you must prioritize Rated Voltage (kV) and Rated Current (A) to match your grid requirements. Key performance metrics include the Short-circuit Breaking Capacity (kA), which determines the device's ability to interrupt faults safely, and the Mechanical Life (number of operations), typically requiring at least 10,000 cycles. Additionally, ensure the controller supports multiple reclosing attempts (1-3 times) with adjustable dead time intervals to optimize grid stability.

Which international compliance standards are mandatory for this product category?

For global trade, the product must adhere to IEC 62271-111 or IEEE C37.60, which are the primary standards for overhead, pad-mounted, dry-type, and submersible automatic circuit reclosers. For the European market, CE marking and RoHS compliance are essential. If exporting to North America, look for ANSI/IEEE certifications. Always request Type Test Reports from accredited third-party laboratories like KEMA, TUV, or Intertek to verify performance under extreme conditions.

What communication protocols are necessary for Smart Grid integration?

Modern B2B buyers should ensure the recloser's Intelligent Electronic Device (IED) supports standard protocols such as IEC 60870-5-101/104, DNP3.0, or Modbus TCP/RTU. Compatibility with SCADA systems is crucial for remote monitoring and control. Check if the unit offers GPRS/4G wireless modules or Fiber Optic interfaces to facilitate real-time data transmission and fault location, isolation, and service restoration (FLISR).

How does the insulation medium affect the choice of an auto recloser?

The choice between SF6 gas insulation, Solid Dielectric (Epoxy Resin), or Oil insulation depends on environmental regulations and maintenance capabilities. Solid Dielectric insulation is increasingly preferred due to its eco-friendly nature (zero gas leakage risk) and minimal maintenance requirements. However, SF6 units are still widely used for their excellent arc-extinguishing properties in high-voltage applications, provided they include pressure gauges and leakage alarms.

Cross-Border Procurement Strategy & Risk Management

How can I mitigate the risk of receiving sub-standard electrical equipment?

Implement a strict factory audit and Pre-Shipment Inspection (PSI). For high-value electrical components like reclosers, hire a third-party inspector to perform a Routine Test (including power frequency withstand voltage and timing tests) before the balance payment is made. On Made-in-China.com, prioritize Audited Suppliers who have undergone on-site verification by independent agencies like SGS or Bureau Veritas.

What are the best practices for negotiating with high-voltage equipment suppliers?

Focus on the Total Cost of Ownership (TCO) rather than just the unit price. Negotiate for an extended warranty period (typically 18-24 months) and the inclusion of essential spare parts (e.g., control cables, mounting brackets). For bulk orders, request a 5-10% discount or ask the supplier to cover the costs of customized firmware localization to match your local grid language and parameters.

What shipping precautions are necessary for sensitive electronic controllers?

Auto reclosers contain sensitive electronic controllers and heavy vacuum interrupters. Ensure the supplier uses IP65-rated stainless steel enclosures for the product and seaworthy wooden crate packaging with shock-absorbent padding. Request moisture-proof vacuum sealing for the control box and ensure the shipment is insured under ICC(A) terms to cover all risks during transit.

How do I ensure transaction security in large-scale B2B electrical trades?

Utilize secure payment methods such as Letters of Credit (L/C) for large volumes or Escrow-based trade assurance services provided by platforms like Made-in-China.com. This ensures that funds are only released to the supplier once you have confirmed receipt and inspection of the goods, protecting your capital against non-delivery or quality disputes.