SourcingAI

Converter of electromagnetic flowmeter

I have found results from4000+products and1000+suppliers aboutConverter of electromagnetic flowmeter

Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Resonant Pressure Sensor
Type: DC Transmitter
Electromagnetic Flow Meter
Accuracy: ±0.2-0.5%
Main Application: Water
Certification: CE
Task: Program
Structure: Combination
Mathematical Model: Linear
Signal: Continuous
Function: Automatic Control
Condition: New
Customized: Customized
Material: Aluminum Alloy
Component: SemiConductor Type
Strain Gauge Pressure Transmitter
Output Signal Type: Digital Type
Production Process: Normal Wirewound
Thread Type: ZG
Wiring Type: Five-Wire
Measuring Medium: Steam
IP Rating: IP67
Connection Type: Flange Type
Accuracy Grade: 0.1G
Display Type: Remote Display
Standard: Celsius/Fahrenheit
Usage: Industrial
Display: Digital
Dry and Wet Bulb Thermometer
Unipolar Integrated Circuit
Input Type: Differential
Integration: GSI
0℃ - 70℃
Resolution: 16 Bit
Shape: DIP
Technics: Semiconductor IC
Kind: Two-wire Transmitter
Size: DN50-100
Sensor: Tube/Flange
Application: Transportation
Measuring Media: Liquid
Measuring Principle: Electrical Principles
Measurement Object: Open Channel
Accuracy: ≤0.5°C
Main Application: Wastewater
Main Application: Diesel Fuel
Main Application: Fuel Oil
Main Application: Nature Gas
Main Application: Corrosive Liquid/Gas
Certification: ISO
Certification: CCC
Certification: RoHS
Certification: JIS
Certification: DIN
Function: Protection
Function: Monitoring
Function: Measurement
Customized: Non-Customized
Material: Metal
Material: Thermocouple
Mechanical Structure Type
Thread Type: M
Wiring Type: Four-Wire
Measuring Medium: Liquid
IP Rating: IP68
Accuracy Grade: 0.2G
Application: Industrial Production
Measurement Object: Closed Pipeline

Sourcing guidance for Converter Of Electromagnetic Flowmeter

What are the key technical specifications to consider when selecting a converter for an electromagnetic flowmeter?

When sourcing a converter, you must prioritize excitation stability and signal processing capabilities. Ensure the device supports programmable low-frequency square wave excitation to improve flow stability and reduce power consumption. Key specs include an accuracy class of ±0.5% or ±0.2%, a power supply compatible with your local grid (85-265VAC or 24VDC), and a high-resolution backlit LCD display for real-time monitoring of instantaneous flow, total flow, and velocity.

How do I ensure the converter is compatible with my existing flow sensor and industrial network?

Compatibility is critical for seamless integration. Verify that the converter supports standard output signals such as 4-20mA current loops, pulse outputs, and RS485 (Modbus protocol). For advanced automation, check for HART, Profibus, or GPRS/NB-IoT wireless capabilities. Additionally, ensure the excitation current and frequency are adjustable to match the specific requirements of your electromagnetic sensor (primary) to avoid measurement errors.

What environmental and compliance standards are necessary for industrial-grade converters?

For harsh environments, the converter must have an IP65 or IP67 protection rating to ensure dust and water resistance. If the application involves hazardous areas, look for Ex-proof (Explosion-proof) certifications such as ATEX or IECEx. Furthermore, ensure the product complies with CE marking for the European market or UL standards for North America, and verify that the manufacturer follows ISO 9001 quality management systems.

What are the common usage scenarios and functional requirements for these converters?

Converters are widely used in water treatment, chemical processing, and food & beverage industries. Functional requirements should include empty pipe detection, bi-directional flow measurement, and self-diagnosis functions (e.g., excitation circuit alarms). For the food industry, ensure the housing is made of corrosion-resistant materials like stainless steel or high-strength aluminum alloy with a protective coating.

Cross-Border Procurement Risks and Strategic Advice

How can I mitigate the risk of receiving defective or incompatible electronic components?

Always request a technical datasheet and wiring diagram before purchase to confirm compatibility. Utilize third-party inspection services (such as SGS or Intertek) to conduct a Pre-Shipment Inspection (PSI), focusing on power-on tests and signal output accuracy. For secure transactions, use the secured payment services provided by Made-in-China.com to ensure funds are only released upon confirmation of goods.

What strategies should be used when negotiating with Chinese manufacturers for bulk orders?

Focus on the Total Cost of Ownership (TCO) rather than just the unit price. Negotiate for a longer warranty period (typically 18-24 months) and request a spare parts kit (1-2% of order value) for critical components like fuses or display modules. For large volumes, ask for tiered pricing where the unit cost drops by 10-15% when reaching specific MOQ thresholds.

What are the logistics and customs considerations for shipping precision instruments?

Converters contain sensitive electronics; ensure the supplier uses anti-static packaging and shock-absorbent foam within double-walled corrugated boxes. For shipping to international markets, clarify the HS Code (typically 902610) to determine import duties. Choose FOB terms if you have a reliable freight forwarder to better control shipping costs and transit times, especially for air freight which is recommended for high-value electronics.

Related queries