SourcingAI

Disinfection chamber

I have found results from20000+products and10000+suppliers aboutDisinfection chamber

Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Cold Stamping
Gas Sterilization Equipments
Type: Drying Oven
Type: Lightwave Disinfection
High Voltage Electric Field Sterilization Equipment
Type: Self-Cleaning
Type: Electronic Chain
Type: Daily Products
Type: Incubator
Processing Type: Deep Drawing
Material: Stainless Steel
Simple Single Process Dies
Surface Processing: Polishing
Fine Blanking: Open
Process: Separation Process
Metal Stamping Parts
Tolerances: 0.1mm
Customized: Customized
Certification: ISO9001
Application: Industry
Voltage: 220V
Disinfection Method: Ultraviolet
Theory: Pneumatic
With LCD Display
Ultra High Temperature Alarm
Sterilization Information Recording and Printing
Structure: Desktop
Operational Method: Continuous
Electric Tension: 220V
Form: Portable
Scale: Large
Automation: Automatic
Operation: Continuous
Energy: Heat Sterilization
Property: Physical Sterilization
Optional Accessory: Timer Switch
Noise: 60-70db
Surface Treatment: Baking Finish
Inside Diameter: 400*400*400mm
Installation: Embedded Type
Operating Principle: Laminar
Movement Way: Fixed
Atomization: Pressure Atomization
Flow: Cross Flow
Heating Mode: Transmission
Material Status: Powder
Drying Medium: Air
Operation Pressure: Vacuum
Fast Installation: Fast Installation
Feature: Earthquake Resistant
Condition: New
Screw: Multi-Screw
Function: Exhaust
Hood Type: Standard
Color: Grey
Usage: Hospital
Warranty: 1 Year
Normal Pressure and Temperature
Display: Digital Display
Performance: Automatic
Weight: 50-100kg
Environmental Condition: Indoor
Payment: Swiping Card
Coin and Note
Touch Screen: Touch Screen
With Power-off Protection
Support Extended Networking
Without Small Change
With Failure Self Detection
Material: Sandwich Panel
Customized: Non-Customized
Certification: CE
Certification: ISO13485
Certification: ISO
Certification: RoHS
Application: School
Application: Hospital
Application: Lab
Application: Museum
Application: Prison
Application: Pier
Application: Station
Application: Household
Theory: Pressure Steam
Without LCD Display
Structure: Tunnel
Optional Accessory: Sterilization Lamp
Optional Accessory: Floodlight
Inside Diameter: 700*700*700mm
Operating Principle: Ordinary Type
Material Status: Solution
Material Status: Strap
Material Status: Bulk
Feature: Easily Movable
Feature: Eco-Friendliness
Feature: Flexibly Combinable
Feature: Leak Proof
Feature: Moisture Proof
Feature: Safe
Feature: Thermal Insulation
Feature: Waterproof
Feature: Wind Resistance
Feature: Corrosion Resistance
Feature: Easy Cleaning
Feature: Easy Disinfection
Function: Insulation
Color: White
Usage: Research Institute
Usage: Auto
Usage: Door

Sourcing guidance for Disinfection Chamber

What are the key technical specifications to consider when selecting a Disinfection Chamber?

When sourcing a disinfection chamber, prioritize the atomization technology (ultrasonic vs. pressure spray) to ensure a fine mist that covers all surfaces without soaking the user. Look for high-precision infrared sensors for automatic induction, ensuring a touchless experience. The disinfectant tank capacity should be at least 15-20 liters for high-traffic areas to minimize refill frequency. Additionally, verify the frame material; 304 stainless steel or powder-coated aluminum is essential for corrosion resistance against chemical disinfectants.

Which compliance standards and certifications are mandatory for international trade?

Compliance is critical for medical and sanitary equipment. Ensure the product carries the CE Marking for the European market or FDA registration for the US. The electrical components must meet LVD (Low Voltage Directive) and EMC (Electromagnetic Compatibility) standards. If the chamber uses UV-C light, it must comply with IEC 62471 for photobiological safety to ensure it does not harm human skin or eyes during operation.

How can I evaluate the efficiency and safety of the disinfection process?

Request third-party lab test reports demonstrating a kill rate of ≥99.9% against common pathogens. For chambers used by people, ensure the system includes a voice prompt or visual signal to guide the user through the correct timing (usually 5-10 seconds). If using chemical mists, confirm the supplier provides a Material Safety Data Sheet (MSDS) for the recommended disinfectant to ensure it is non-toxic and non-irritating to the respiratory system.

What are the typical usage scenarios for industrial-grade disinfection chambers?

These units are designed for high-density entry points such as hospitals, schools, airports, construction sites, and food processing plants. For industrial settings, look for models with heavy-duty casters for mobility and integrated temperature measurement modules (thermal imaging) to provide a dual-function screening and disinfection station.

Cross-Border Procurement Risks and Strategies

How can I mitigate transaction risks when purchasing from overseas suppliers?

Always utilize secure payment terms and conduct due diligence via Made-in-China.com, focusing on Audited Suppliers who have undergone on-site inspections. It is highly recommended to hire a third-party inspection service (like SGS or Intertek) to perform a Pre-Shipment Inspection (PSI) to verify that the technical parameters and safety features match your order specifications before final payment.

What are the logistics and shipping precautions for disinfection chambers?

Disinfection chambers are often bulky and contain sensitive electronics. Ensure the supplier uses IPPC-certified wooden crate packaging with internal shock-absorption foam. If the unit includes a built-in battery for the thermal sensor, it must be declared as Dangerous Goods (DG) under UN3481 regulations. For shipping to the US or Europe, clarify the Incoterms; DDP (Delivered Duty Paid) is often preferred for buyers who want the supplier to handle complex customs clearance and import duties.

How should I negotiate with suppliers regarding customization and after-sales support?

Negotiate for a 1-2% spare parts kit (including extra nozzles, sensors, and pumps) to be included in the initial bulk order, as these are the most common points of failure. Demand a minimum 12-month warranty and confirm the availability of English-language technical manuals and video installation guides. For orders exceeding 10 units, aim for a 10-15% volume discount and request OEM branding (logo placement) to be included at no extra cost.

Related queries