SourcingAI

phase auto recloser

I have found results from1000+products and600+suppliers aboutphase auto recloser

Commonly used:
US$
Customization Available
Sample Available
Manufacturer First
Product attributes:
Type: Circuit Breaker
Type: High-voltage
High Voltage Circuit Breakers
Operation: Electric Type
High-Speed Circuit Breaker
Arc-extinguishing Medium: Vacuum
Installation: Fixed
Structure: ACB
Poles Number: 3
Conventional Circuit Breaker
Certification: VDE
Application: Power
Phase: Three
Core: Core-type Transformer
Winding Type: Auto-transformer
Usage: Rectifier Transformer
Frequency Characteristics: High Frequency
Shape of Core: OD
Shell Material: Stainless Steel
Voltage Level: Medium Voltage
Current: AC
Grounding Mode: Grounding
Series: Three
Structure of Operating: Electric
Low Voltage Circuit Breakers
Operation: Energy-storage Type
Operation: Manual Type
Operation: Electric
Normal Type Circuit Breaker
Installation: Outdoor High-voltage
Installation: Open Frame
Structure: Cabinet
Structure: Three-column Disconnector
Poles Number: 1
Circuit-Breaker Failure Protection
Function: Overcurrent Protection
Function: OVP(Overvoltage Protection)
Function: RCCB
Certification: ISO9001-2000
Certification: CE
Certification: CB
Certification: CCC
Certification: ISO9001
Certification: ISO
Certification: UL
Application: Electronic
Application: Rectifier

Sourcing guidance for Phase Auto Recloser

What are the key technical specifications to prioritize when selecting a Phase Auto Recloser?

When sourcing a Phase Auto Recloser (ACR), you must prioritize Rated Voltage (typically 11kV, 15kV, 27kV, or 38kV) and Rated Continuous Current (630A to 1250A). Ensure the unit features Vacuum Interruption technology for arc quenching and Solid Dielectric Insulation (Cycloaliphatic Epoxy) to eliminate the risks associated with oil or SF6 gas. Additionally, verify the Short-circuit Breaking Capacity (kA) matches your grid's fault levels to prevent catastrophic equipment failure.

Which international compliance standards are mandatory for global distribution?

The product must strictly adhere to IEEE C37.60 / IEC 62271-111, which is the specific international standard for overhead, pad-mounted, dry vault, and submersible automatic circuit reclosers. For the electronic controller, ensure compliance with IEC 60255 for protective relays and IP65 or higher ingress protection for the control cabinet to withstand harsh outdoor environments. CE and ISO 9001 certifications are baseline requirements for manufacturing quality.

What communication protocols and smart grid integration features are necessary?

Modern power distribution requires compatibility with DNP3, IEC 60870-5-101/104, or Modbus protocols to ensure seamless integration into SCADA systems. Look for controllers that support GPRS/4G wireless communication and have built-in FTU (Feeder Terminal Unit) functions. This allows for remote monitoring, fault location, and automated grid restoration, which are essential for reducing SAIDI (System Average Interruption Duration Index).

How do I evaluate the mechanical and electrical durability of the recloser?

Request test reports confirming a Mechanical Life of at least 10,000 operations. For electrical endurance, the unit should handle rated short-circuit making current multiple times without degradation. Check if the supplier provides Type Test Reports from accredited third-party labs (like KEMA or CPRI) to validate these performance benchmarks before finalizing a bulk purchase.

Cross-Border Procurement Strategy & Risk Mitigation for Power Equipment

How can I mitigate the risks of technical incompatibility in international trade?

Power grids vary by country; always provide the supplier with your specific Grid Frequency (50Hz vs 60Hz) and CT/PT (Current/Potential Transformer) ratios. Request a technical drawing and parameter confirmation sheet for sign-off before production begins. Utilizing the inspection services on Made-in-China.com can help verify that the physical product matches the technical data sheet provided during negotiation.

What are the best practices for shipping and handling heavy electrical equipment?

Phase Auto Reclosers are sensitive high-voltage instruments. Ensure the supplier uses IPPC-certified fumigated wooden crates with internal shock-absorption padding. Demand moisture-proof vacuum packaging for the control box to prevent corrosion during sea freight. It is highly recommended to use CIF (Cost, Insurance, and Freight) terms and include 'All Risks' insurance to cover potential damage during transit.

How should I negotiate after-sales support and warranty for cross-border orders?

Since on-site repair is difficult across borders, negotiate for a 2% to 5% spare parts kit (including PC boards and coils) to be included with the shipment. Secure a warranty period of at least 18-24 months. Ensure the supplier provides English-language technical manuals and video installation guides, and confirm they offer remote technical support via video conferencing for commissioning.

What transaction security measures should be taken for high-value B2B orders?

For high-value electrical assets, use Secured Payment services provided by Made-in-China.com to ensure funds are only released upon proof of shipment. For very large orders, consider a Letter of Credit (L/C). Always conduct a factory audit (either in-person or via a third-party agency) to verify the supplier's production capacity and testing laboratory equipment.