SourcingAI

Whiteness meter

I have found results from10000+products and4000+suppliers aboutWhiteness meter

Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Balancing Machine
Salt Spray Testing Machine
Corn Moisture Meter
Display: Digital
Application: Industrial
Warranty: 1 Year
Detection Method: Spectrophotometer
Advantage: High Resolution
Principle: Classic Spectrometer
Wavelengths: Visible Spectrometer
Dispersive Element: Grating Spectrometer
Certification: RoHS
Customized: Non-Customized
Maxcapacity: <1000KN
Accuracy Grade: 0.5
Load Way: Electronic Load
Weight: 0-100Kg
Power Source: AC220V
Max Diameter of Workpiece: <500mm
Mass Scope of Workpiece: <900kg
Loading Method: Dynamic Load
Control: Manual Control
Oil Cylinder Position: Under
Accuracy: ± 1.5%
Transmission-type Density Meter
Viscometer Type: Rotary
Float-type Density Meter
Test Density: Heavy
Viscometer Reproducibility: ±0.2%
Viscometer Rotor Number: 4
Viscometer Rotor Speed: 60r/min
Viscometer Rotor Specifications: 0 Size
Analysis Method: Physical Analysis
Portable: Portable
Off Mode: Manual
Light Number: Polychromator
Display: LED
Application: Laboratory Apparatus
Agriculture & Food
Detection Method: Spectrograph
Dispersive Element: Interferometer Spectrometer
Certification: ISO9001
Certification: CE
Customized: Customized
Maxcapacity: >1000KN
Accuracy Grade: 1
Loading Method: Static Load
Control: Computer Control

Sourcing guidance for Whiteness Meter

What are the key technical specifications to consider when selecting a Whiteness Meter?

When evaluating a Whiteness Meter, you must prioritize the Light Source (D65 is the standard for daylight simulation) and the Measuring Geometry (typically d/0 or 45/0). Ensure the device offers high Repeatability (ΔE*ab ≤ 0.05) and Inter-instrument Agreement to guarantee consistent readings across different batches. For industrial applications, look for a Large Data Storage Capacity and USB/Bluetooth connectivity for seamless data export to quality control software.

Which international standards and compliance certifications are mandatory for Whiteness Meters?

The instrument must comply with international colorimetric standards such as ISO 2470, ISO 2471, and CIE (Commission Internationale de l'Eclairage). For specific industries like paper or textiles, verify adherence to TAPPI T452 or ASTM E313. Additionally, ensure the supplier provides a Calibration Certificate traceable to national metrology institutes and that the device carries CE and RoHS certifications for entry into European markets.

How do different application scenarios affect the choice of a Whiteness Meter?

The choice depends heavily on the physical state of the sample. For flat surfaces like paper, plastic, or salt, a standard aperture is sufficient. However, for powders, granules, or liquids, you must ensure the supplier provides specialized sample cells or powder boxes to prevent contamination of the optics. For field testing, a Portable/Handheld model with long battery life is ideal, whereas a Benchtop model is preferred for high-precision laboratory R&D.

What maintenance and calibration routines are required for long-term accuracy?

To maintain accuracy, the device requires Daily White and Black Calibration using the provided standard tiles. It is critical to keep the optical window clean and free of dust. Professional buyers should inquire if the supplier offers annual recalibration services and if the standard white plate is protected by a specialized cover, as any scratches or yellowing on the calibration tile will lead to incorrect measurements.

Cross-Border Procurement Strategies for Precision Instruments

How can I mitigate the risks of purchasing precision optical instruments from overseas?

Precision instruments are sensitive to vibration and moisture. You should insist on Vacuum Packaging and Shock-Absorbent Foam within a sturdy wooden crate. Furthermore, use Made-in-China.com's Secured Trading services to ensure that payment is only released after the goods pass a Third-Party Inspection (such as SGS or Intertek), which should verify the instrument's power-on functionality and calibration accuracy before shipment.

What are the best practices for negotiating with Whiteness Meter suppliers?

Focus the negotiation on After-Sales Technical Support and Warranty Extensions. Since these are technical products, ask for a 2-year warranty instead of the standard 12 months. Negotiate for the inclusion of extra calibration tiles or sample holders at a discounted rate. For bulk orders, aim for a 10-15% price reduction by highlighting a long-term partnership and requesting OEM/ODM branding if you are a distributor.

What shipping methods and trade terms are recommended for high-value lab equipment?

For high-value, low-volume items like Whiteness Meters, Air Freight or International Express (DHL/FedEx/UPS) is recommended to minimize transit time and handling risks. Use CIP (Carriage and Insurance Paid to) or CIF (Cost, Insurance, and Freight) terms to ensure the seller covers the insurance during transit. Always verify the HS Code (typically 9027.50) to accurately calculate import duties and taxes in your destination country.

Related queries