SourcingAI

X ray machines for sale

I have found results from60000+products and20000+suppliers aboutX ray machines for sale

Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
X Ray Equipment
Type: Dental Unit
Veterinary X Machine
Type: X-Ray Equipment
Cleaning & Filling Teeth Equipments
Digital Imaging System
Imaging Diagnostic Equipment
Certification: CE
Group: Male
Breathing Pattern: Auto-Control
Animal Anesthesia Machine Control Method: Electronic Control
Customized: Customized
Scale: Medium
Material: PVC
Applicable Departments: Oral Surgery
Weight: >10T
Material Feature: Heat Resistant
Energy Saving: Energy Saving
Warranty: 1 Year
Color: Yellow
Condition: New
Voltage: 220V
Cold Light Whitening
Certification: FDA
Certification: EEC
Certification: MSDS
Certification: ISO13485
Certification: ISO
Certification: ISO9001:2008
Middle-aged and Old
Scale: Large
Material: Metal
Material: Carbon Steel
Oral Department of Internal Medicine
Weight: 8T
Color: Blue

Sourcing guidance for X Ray Machines For Sale

What are the key technical specifications to consider when purchasing an X-ray machine?

Buyers must evaluate the Generator Power (kW), typically ranging from 32kW to 80kW depending on the clinical application. For high-quality imaging, prioritize machines with a High-Frequency Generator to ensure radiation stability. Additionally, check the Digital Detector (FPD) type; Cesium Iodide (CsI) detectors are preferred over Gadolinium Oxysulfide (GOS) for their higher Detective Quantum Efficiency (DQE) and lower patient dose. Ensure the Pixel Pitch is small (e.g., 139μm or 140μm) for superior image resolution.

What international compliance standards and certifications are mandatory for X-ray equipment?

Medical X-ray machines are strictly regulated. Suppliers must provide ISO 13485 (Medical Devices Quality Management Systems). For market entry, the equipment must have CE Marking (MDD/MDR) for Europe or FDA 510(k) clearance for the United States. Furthermore, ensure the product complies with IEC 60601-1 (General requirements for basic safety and essential performance) and IEC 60601-2-54 for X-ray equipment to guarantee electrical and radiation safety.

How do I choose between Fixed, Mobile, and Portable X-ray systems?

The choice depends on the Usage Scenario. Fixed Digital Radiography (DR) systems are best for high-volume hospitals requiring heavy-duty performance and floor/ceiling mounts. Mobile X-ray units are essential for ICU or bedside imaging, featuring motorized movement and battery-powered operation. Portable X-ray machines are ideal for field clinics, veterinary use, or emergency response, prioritizing lightweight design (often under 20kg) and ease of transport.

What software and integration capabilities should a modern X-ray machine have?

Ensure the system is fully DICOM 3.0 compliant to allow seamless integration with PACS (Picture Archiving and Communication Systems) and HIS/RIS (Hospital/Radiology Information Systems). Look for advanced Image Processing Software that includes features like Automatic Exposure Control (AEC), noise reduction, and bone enhancement algorithms to improve diagnostic accuracy.

Cross-Border Procurement Risks and Strategic Advice

How can I mitigate the risks of purchasing high-value medical equipment cross-border?

Utilize Trade Assurance services provided by platforms like Made-in-China.com to protect your payment until delivery is confirmed. It is highly recommended to hire a third-party inspection agency (such as SGS or Bureau Veritas) to conduct a Pre-Shipment Inspection (PSI). This inspection should verify the tube serial numbers, software versions, and radiation leakage tests before the final balance is paid.

What are the specific shipping and packaging requirements for X-ray machines?

X-ray machines contain sensitive electronics and fragile vacuum tubes. Requirements include vacuum-sealed moisture-proof packaging and reinforced wooden crates (ISPM 15 compliant). Ensure the shipment includes Shockwatch and TiltWatch sensors on the exterior crates to monitor for mishandling during transit. For international logistics, Air Freight is recommended for high-end digital detectors to minimize vibration, while the mechanical stand can be shipped via Sea Freight to save costs.

What strategies should be used when negotiating with medical equipment suppliers?

Focus on the Total Cost of Ownership (TCO) rather than just the unit price. Negotiate for an extended warranty (24-36 months) on the X-ray tube and detector, as these are the most expensive components to replace. Request the supplier to include remote technical support and spare parts kits (e.g., cables, fuses, switches) in the initial contract. For bulk orders, aim for a 15-20% discount or free installation training for your local engineers.

How do I handle customs clearance for radiation-emitting devices?

Buyers must verify if a Radiation Safety License or an Import Permit for Medical Devices is required by their local Ministry of Health or Atomic Energy Agency. Ensure the supplier provides a detailed Commercial Invoice, Packing List, Certificate of Origin, and specifically the Radiation Safety Test Report. Failure to provide these can lead to severe customs delays or seizure of the equipment.