SourcingAI
Try for free
Powered by Made-in-China.com
Acrel Ascb-63-C16-1p Smart Remote Control Circuit Breaker for Low Voltage Applications
US$62.00-103.00
1 Piece

Product profile

Customization

Available

Breaking Capacity

Low Voltage Circuit Breakers

Operation

Electric Type

Model NO.

ASCB1-63-C16-1P

Speed

Normal Type Circuit Breaker

Structure

MCB

Poles Number

1

Type

Circuit Breaker

Function

Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB

Certification

ISO9001-2000, CE, CCC

Electrical Life

6000 Times

Mechanical Life

20000 Times

Connection Capacity

1-35 Sqm

Instantaneous Unbuckle Type

C/D

Leakage Protection

Default 20mA Alert, 30mA Trip

Over-Current Protection

Default 100% Rated Current Alert

Default 100% Rated Current Alert

IP20

Rated Current

16A, 6A,10A,16A,20A,25A,32A,40A,50A,63A

Rated Voltage

AC 230V

Bcd Curve

C

Transport Package

Carton

Specification

109*75*36mm

Trademark

Acrel

Origin

China

Production Capacity

200000

Key features

RS485 Communication Interface: Built-in RS485 interface for direct data collection without additional gateway.
Comprehensive Protection Functions: Features over-current, over-voltage, under-voltage, over-temperature, and leakage protection.
Adjustable Protection Thresholds: Alert and trip thresholds for current, power, voltage, temperature, and leakage are adjustable.
Remote Control Capability: Integrates release function to realize remote opening and closing operations.
Long Mechanical Life: Designed for 20,000 mechanical operations ensuring long-term reliability.
Standard Installation: Fits standard 35mm guide rail with simple clip-and-fix installation method.
Self-Inspection Function: Manual button self-inspection available for leakage protection verification.
Wide Current Range: Available in rated currents from 6A to 63A to suit various load requirements.

Company profile

ACREL CO., LTD.
Exhibition ExperienceQuality AssuranceR&D CapabilitiesManagement Certification
ACREL CO., LTD.Shanghai, China
CertifiedBusiness Type: Manufacturer/Factory & Trading Company CertifiedR&D Capacity: ODM Service Available CertifiedCustomization Options: Customization from Samples, Customization from Designs, etc. CertifiedExport Year: 4 Years CertifiedNearest Port: Shanghai PortAverage Response Time: ≤4.74h

AI-Powered supplier vetting

SummaryThe supplier demonstrates broad electrical, power-electronics, automation, IoT, software, and related equipment business coverage. It has documented procedures for corrective and preventive actions, complaint handling, supplier-service assessment, and finished-product inspection. Its capabilities include 3D software design, ODM, SDK provision, new-product development, extensive customization, SMT/DIP production, automated sensing, debugging, and testing. Overseas support is available through agents or branches in Singapore, including installation, training, repair, maintenance, and debugging. However, the supplier has no reported in-stock capacity, overseas warehouse, overseas showroom, or valid manufacturing-capacity contract with related subcontractors. Evidence is insufficient for certification holding and customer cases.
Supplier typeThe stated business scope covers electrical signal equipment, power-electronic components, instruments and meters, software, intelligent equipment, lighting, IoT and information-security devices, charging stations, power-distribution control equipment, and industrial automation systems. Its facilities include SMT and DIP assembly lines plus automatic sensing, debugging, and testing equipment, indicating a manufacturer and technical equipment supplier rather than a purely trading-oriented entity.
After-Sales capabilityThe supplier has documented complaint-handling and corrective/preventive-action procedures with records, and overseas service capability through agents or branches in Singapore covering installation, training, repair, maintenance, and debugging. However, it reports no overseas warehouse and no overseas showroom; these are logistical limitations but do not negate the documented service functions.
R&D capabilityThe supplier provides 3D software design, ODM, SDK access, and multiple forms of customization, and reports new products during the past year. Nevertheless, it states that it has not established an AI model for big-data processing and decision-enabled management, which is a stated sustainability and digital-management gap rather than proof of insufficient product innovation.
Production capacityProduction evidence includes SMT and DIP assembly lines, automatic electricity-sensor production, and automatic debugging and testing equipment; finished-product inspection instructions are uniformly followed. Lead times are stated as within 15 workdays in both peak and off-seasons, but the supplier reports no in-stock capacity and no valid manufacturing-capacity contract with related subcontractors, limiting evidence of flexible or backup capacity.
Customization capabilityThe supplier explicitly offers customization from samples, customization from designs, full customization, minor customization, flexible customization, 3D software design, and ODM services. These combined statements provide direct evidence of broad customization and design-development capability.

Product Q&A

Q:Can the circuit breaker data be collected through RS485 communication?
A:
The circuit breaker has its own RS485 communication interface, and it does not need to be equipped with an ASCB1-M gateway to access the customer system, but the customer needs to provide the circuit breaker with DC12V 12A auxiliary power supply
Q:How many circuit breakers can a gateway carry?
A:
16PCS
Q:How Gateways and Circuit Breakers are Networked?
A:
The gateway and the circuit breaker are connected by a 4pin cable, a set of DC12V auxiliary power supply, and a set of RS485 communication lines. The connection between the circuit breaker and the circuit breaker is the same. One-key addressing operation through the gateway
Q:Does the circuit breaker need to be equipped with additional accessories?
A:
1. Internally integrate various sensor modules, including: current sensor, leakage transformer, temperature sensor, etc.; 2. The circuit breaker integrates the release function, which can realize remote opening and closing operations; 3. Configure the circuit breaker network cable
Q:What is the rated short-circuit breaking capacity?
A:
6000A

Send Inquiry

*To:ACREL CO., LTD.ACREL CO., LTD.
*Content:
0/4000

Supplier replies will be sent to your registered email