Powered by Made-in-China.com
Water Treatment Non-Oxidizing Biocide RO Biocide Agent
US$950.00
1-49 Tons
US$900.00
50+ Tons
Product specifications
Color
Sample price:US$0.00/piece.Request sample
Product profile
Customization
AvailableCAS No.
CompoundFormula
CompoundModel NO.
ProtecMBC1560WEINECS
CompoundAcid-Base Property
Acidic Surface Disposal AgentEnvironmental Protection
YesColor
Light Blue-Green Transparent LiquidAppearance
LiquidType
Industrial Circulating Water Treatment AgentProduct Name
Membrane Scale InhibitopH(1%)
≤7.0Density (20°C) G/Cm³
≥1.02Storage
Shady and VentilatedTransport Package
Blue / White Plastics DrumSpecification
25 kg/200 kg/1 ton drumTrademark
Scien GreenOrigin
Jining City, Shandong Province, ChinaProduction Capacity
15000 Ton/YearKey features
Broad-Spectrum Microbial Control Rapidly eliminates bacteria, fungi, algae, and biofilms commonly found in RO systems
Effective against both planktonic and sessile microorganisms for comprehensive protection
Available in oxidizing (1562, 1563) and non-oxidizing (1560, 1561) formulations to me application needs
Superior Membrane Compatibility
100% compatible with all RO membrane materials (polyamide, cellulose acetate, etc.
Non-oxidizing variants (1560, 1561) won't damage polyamide membranes like chlorine-based alternatives
No negative impact on membrane performance (flux rate, salt rejection) when used as directed
Powerful Biofouling Control
Strong biofilm and slime stripping capabilities to remove existing microbial deposits
Prevents new biofilm formation through long-lasting residual activity
Reduces transmembrane pressure (TMP) increase and maintains consistent water production
Versatile & User-Friendly
Wide pH compatibility range (typically 5.0-9.0) for various water conditions
Safety & Environmental Compliance
Non-flammable, non-volatile, and low-toxicity formulations for safe handling
Good biodegradability minimizes environmental impact
Cost-Effective Performance
Highly effective at low concentrations (ppm levels) reducing operational costs
Company profile
CertifiedBusiness Type: Manufacturer/Factory & Trading Company CertifiedR&D Capacity: ODM Service Available & OEM Service Available CertifiedCustomization Options: Customization from Samples, Customization from Designs, etc. CertifiedExport Year: 13 YearsNearest Port: QingdaoAverage Response Time: ≤1.25h
About Our Factory & Business Background
AddressJining Economic Development Zone, Jining, Shandong, China
Plant Area5933 square meters
Number of Employees296
Registered Capital60,000,000 RMB
Terms of PaymentT/T, LC, Western Union, PayPal
International Commercial Terms(Incoterms)FOB, CIF, CFR, EXW
Average Lead TimePeak Season Lead Time: within 15 workdays Off Season Lead Time: within 15 workdays
Minimum Order Quantity1 Ton
Supply Chain Partners25
Our Production Capability & Technical Expertise
Main ProductsWater Treatment Chemical, Corrosion Inhibitor, Scale Inhibitor, Biocide Algicide Agent, Demulsifier, Defoamer, Cutting Fluid, Industrial Cleaning Agent, RO Membrane Antiscalant, Flocculant
Production Lines4
Production MachinesWater Storage Tank, Reactor, Reverse Osmosis Device
QA/QC inspectors9 people
Inspection Type for Finished Products100% inspection(Visual inspection & Function inspection)
Inspection Method for Finished ProductsHave instructions and uniformly followed
R&D Engineers60 people
Traceability of Raw MaterialsYes
Own BrandYes
Our Industry Experience & Global Business Record
Year of Establishment2005-01-18
Main MarketsNorth America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
Repeat Buyers Choice50%~80%
Number of Foreign Trading Staff3
Overseas Agent/BranchNo
New Products Launched in Last yearNo
Our Certifications, Standards & Industry Recognition
Management System CertificationISO9001:2015, ISO45001:2018, ISO14001, Others
Cooperated with Fortune 500No
Product Q&A
Q:What is the difference between oxidizing and non-oxidizing RO biocides?
A:
Oxidizing biocides use chemical oxidation to kill microbes, providing rapid, broad-spectrum control. Non-oxidizing biocides disrupt microbial metabolism without oxidation, offering longer residual protection and better compatibility with polyamide membranes. Oxidizing biocides may require neutralization with a reducing agent before contact with polyamide membranes.
Q:How do I choose the right Sungreen RO biocide for my system?
A:
Selection depends on:
Membrane type: Polyamide membranes require non-oxidizing biocides or properly neutralized oxidizing biocides
Water quality: High organic content may require shock treatment with oxidizing biocides
System design: Continuous dosing systems often use non-oxidizing biocides for residual protection
Regulatory requirements: Local discharge regulations may influence selection
Contact our technical team for a free water analysis and customized recommendation.
Q:What is the recommended dosage and application method?
A:
Typical dosage ranges:
Non-oxidizing biocides: 50-200 ppm for shock treatment; 1-5 ppm for continuous dosing
Oxidizing biocides: 1-5 ppm for pre-treatment (must be neutralized to <0.1 ppm residual before membrane contact)
Application methods include:
Continuous injection into feed water
Shock treatment (batch dosing) for severe contamination
Membrane preservation during system shutdown
Always follow the product-specific technical datasheet for precise dosing guidelines
Q:Are Sungreen RO biocides compatible with other water treatment chemicals?
A:
Yes, ProtecMBC series biocides are generally compatible with most RO antiscalants, coagulants, and flocculants. However, we recommend:
Avoid mixing oxidizing and non-oxidizing biocides directly
Maintain proper contact time between chemical additions
Conduct compatibility testing when using new chemical combinations
Q:How do I monitor the effectiveness of the biocide treatment?
A:
Key monitoring parameters:
Microbial counts: Regular ATP or plate count testing of feed
Transmembrane pressure (TMP): Stable TMP indicates effective biofouling control
Biocide residual: Use appropriate test kits to ensure target residual levels
Membrane performance: Maintain consistent flux and salt rejection rates
Send Inquiry
*To:
Scien Green Environment Co., Ltd
Scien Green Environment Co., Ltd*Content:
Supplier replies will be sent to your registered email
You may also like
Effective Chlorine Oxidizing RO Biocide Rapid Algae Removal Water Treatment Agent
US$300.00-450.00
1 Ton(MOQ)
Industrial RO Membrane Cleaning Agent for Water Treatment Systems
US$0.75-0.90
1,000 kg(MOQ)
Non Silicone Defoamer for Water Treatment Antifoam Agent
US$1,200.00-1,500.00
1 Ton(MOQ)
Water Decoloring Agent for Textile and Dye Wastewater Treatment CAS No 55295-98-2
US$600.00-800.00
1 Ton(MOQ)
Antisludging Agent for Circulating Cooling Water Treatment
US$1.00-2.00
2 kg(MOQ)
Bwd-01 Water Decoloring Agent for Wastewater Treatment
US$900.00
1 Ton(MOQ)
RO Membrane Cleaning Agent for Industrial Water Treatment
US$0.75-0.90
1,000 kg(MOQ)
Water Treatment Chemicals Flocculant Decolor Agent
US$750.00-900.00
1 Ton(MOQ)
Water Decoloring Agent for Cotton Textile Non-Pollution
US$0.50-1.00
1 kg(MOQ)
Antisludging Agent for Water Treatment
US$1.00-2.00
2 kg(MOQ)
Swimming Pool Chlorine Activator Liquid Auxiliary Agent for Pool Water Sanitizing Treatment
US$31.67-38.00
100 Pieces(MOQ)
Used in Waste Water Treatment CAS 55895-98-2 Dca Water Decoloring Agent
US$600.00-800.00
1 Ton(MOQ)
Decoloring Agent (DCA) of Textile and Dyeing Waste Water Treatment Chemicals
US$600.00-800.00
1 Ton(MOQ)


















