Model NO.

THR-HV300B LCD

Certification

CE, ISO13485

Group

All People

LCD Display

With LCD Display

Packaging Detail

Carton Box Package or Customers Requirements

Working Frequency

512kHz

Voltage

110-220V,50Hz/60Hz

Power Readouts

Within ±20% or 5W

High Frequency Leaekag

Mono<150mA;Bip<60mA

Transport Package

380*420*280 mm

Specification

8kg

Trademark

THR

Origin

Jiangsu, China

Production Capacity

1000 Piece/Pieces Per Month

Key features

Dual Functionality: Supports both Monopolar and Bipolar modes for versatile surgical needs.
Safety REM System: Return Electrode Monitoring deactivates generator if contact fault is detected.
Low Leakage Current: High frequency leakage is Monopolar <150mA and Bipolar <60mA.
Wide Application: Suitable for General Surgery, ENT, Orthopedics, Neurosurgery, and more.
Multilingual Interface: LCD display supports English, Spanish, Portuguese, Turkish, and other languages.
CE & ISO Certified: Complies with CE and ISO13485 standards for medical equipment safety.
Customizable Accessories: Accessories can be defined to suit specific user needs and preferences.
Compact Design: Net weight is 8kg with dimensions 34x16x47cm for easy handling.

Company profile

Suzhou Thriving Medical Equipment Corp.
Importers and ExportersHigh Repeat Buyers ChoiceYears of Export ExperienceExperienced Team
Business Type: Manufacturer/Factory, Trading CompanyExport Year: 2008-03-26Nearest Port: shanghaiAverage Response Time: ≤10.73hTerms of Payment: LC, T/T, Western UnionInternational Commercial Terms(Incoterms): FOB, CFR, CIF, EXW

AI-Powered supplier vetting

SummaryThe supplier is identified as a limited trading company located in Zhangjiagang, Suzhou, offering hospital and medical-related products. It reports professional technical supplier capability, ODM services, and design customization, but does not provide 3D software design, has no stated new products in the past year, and lacks SDK availability. Export activity is substantial, with 71%–90% of sales from exports and 16 years of exporting experience, supported by self-operated import and export rights. However, the supplier reports no inventory, overseas warehouse, overseas showroom, overseas agents or branches, and no offline trade-show participation. Service and quality-management documentation is weak or unavailable: there are no written procedures or records for supplier assessment, corrective actions, or complaint handling, and quality-control test equipment is reported as zero. Financial information is limited to years shown in the records and does not establish overall credibility. No certifications or...
Supplier typeThe supplier is explicitly classified as a limited company and a trading company, located in Zhangjiagang, Suzhou. Its stated product scope covers hospital beds, medical equipment, autoclaves, stretchers, electric beds, ultrasound scanners, operating lights, and related products, indicating a medical-product trading profile rather than confirmed manufacturing ownership.
After-Sales capabilityAfter-sales and service infrastructure appears limited: the supplier has no in-stock capacity, overseas warehouses, overseas showrooms, overseas agents, or branches, and offers services in zero stated countries. Complaint handling and corrective/preventive action have no written procedures or records, while lead times are stated as within 15 working days off-season and one month during peak season.
R&D capabilityThe supplier is identified as a professional technical supplier and provides ODM services, but it reports no new products during the past year, no SDK availability, and no 3D software design service. This supports some design-and-development involvement but also shows clear limitations in recent product innovation and software-related development.
Customization capabilityCustomization from designs is explicitly available, and the supplier reports ODM capability. These findings support the ability to provide customized products based on customer designs, although the absence of 3D software design services and SDK availability indicates that customization is not supported by those digital-development capabilities.

Product Q&A

Q:What are the main functions of this device?
A:
It features both Monopolar and Bipolar functions to satisfy all surgical demands with safety and flexibility.
Q:Does the device have safety monitoring?
A:
Yes, it includes a Return Electrode Monitoring (REM) system that deactivates the generator if a fault in patient/return electrode contact is detected.
Q:What is the working frequency?
A:
The working frequency is 512kHz.
Q:What is the voltage requirement?
A:
The voltage is 110-220V, 50Hz/60Hz.
Q:What certifications does the product have?
A:
The product is certified with CE and ISO13485.

Send Inquiry

*To:Suzhou Thriving Medical Equipment Corp.Suzhou Thriving Medical Equipment Corp.
*Content:
0/4000

Supplier replies will be sent to your registered email

You may also like

Medical Portable Automatic CPR Device (MS-C1000)

Medical Portable Automatic CPR Device (MS-C1000)

US$3,000.00-9,000.00
1 Piece(MOQ)
Made-in-China.com
Cwm-RC: CE Marked Anesthesiologist Medical Device

Cwm-RC: CE Marked Anesthesiologist Medical Device

US$9,600.00-10,000.00
1 Piece(MOQ)
Made-in-China.com