SourcingAI
Try for free
Powered by Made-in-China.com
All-Season Wet and Dry Closed Cooling Tower for Energy Efficient
US$1,800.00-5,000.00
1 set

Product profile

Customization

Available

After-sales Service

24/7 Full-Time After-Sales Support

Warranty

1 Year

Model NO.

KFCN series

Cooling Method

Counter Flow

Ventilation Mode

Mechanical Ventilation

Material

Metal

Air Contact Form

Wet and Dry

Air Contact Way

Closed

Tower Shape

Square

Noise Level

Low

Application Fields

Industrial

Certification

ISO, CE, CTI, EAC, SGS, TUV

Condition

New

Water Level Control

Automatic Float Valve / Electric Float Valve

Ladder and Handrail

Available

Air Inlet

PVC Louver (Evapco Type)

Drift Rate

≤0.002%

Spray Pump

Large Flow Rate, Low Head

Fill Media

Filler-Free Design

Casing Material

Mg-Al-Zn Coated Steel / Stainless Steel (Optional)

Water Basin

Integrated Water Basin

Dimension

Container-Friendly Design

Driven Motors

Weg / Siemens / Chinese Premium Brand

Fan Type

Axial Flow Fan

Coil Material

Stainless Steel /Copper /Hot-DIP Galvanized Stee

Transport Package

Standard Container

Specification

Customized

Trademark

CASEN

Origin

China

HS Code

84198990

Production Capacity

200 Sets/Month

Key features

Wet-Dry Operation: Supports evaporative and dry cooling modes to adapt the system to different ambient temperatures and operating conditions.
All-Season Performance: Designed for reliable process cooling across changing seasonal conditions and thermal loads.
Winter Water Saving: Dry operation during suitable cold-weather conditions reduces the need for spray water.
Hybrid Heat Exchange: Combines pre-cooling and evaporative heat rejection to improve thermal efficiency
Closed Process Circuit: Keeps process fluid isolated from cooling water and ambient contaminants for cleaner operation.
Automatic Airflow Adjustment: Variable air volume control can adjust fan operation according to cooling demand.
Reduced Scaling Risk: Pre-cooling lowers the thermal load entering the evaporative section and helps control scaling.
Stable Process Temperature: The closed-loop system provides consistent heat rejection for demanding industrial processes.
Reliable Industrial Construction: Designed for continuous operation with robust heat exchange, airflow and water circulation systems.
Customized Operating Strategy: Wet-dry control, airflow, heat exchanger materials and thermal capacity can be configured to suit the project.

Company profile

Shandong Casen Heat Transfer Technology Co., Ltd. Qingdao Branch
Experienced TeamCooperated with Fortune 500Importers and ExportersPatents Awarded
CertifiedBusiness Type: Manufacturer/Factory & Trading Company CertifiedR&D Capacity: ODM Service Available & OEM Service Available CertifiedCustomization Options: Customization from Samples, Customization from Designs, etc. CertifiedExport Year: 6 years CertifiedNearest Port: Qingdao PortAverage Response Time: ≤1.81h

About Our Factory & Business Background

AddressUnit 2706, Building B2, No. 8 Hong Kong Middle Road, Shinan District, Qingdao, Shandong, China
Plant Area16000 square meters
Number of Employees74
Terms of PaymentLC, T/T, D/P, PayPal, Western Union, Small-amount payment
International Commercial Terms(Incoterms)FOB, CIF, CFR, EXW
Average Lead TimePeak Season Lead Time: one month Off Season Lead Time: one month
Minimum Order Quantity1 set
Supply Chain Partners600

Our Production Capability & Technical Expertise

Main ProductsClosed Circuit Cooling Tower, Evaporative Condenser, Integrated Heat Exchange Station, Compound Flow Cooler, Indirect Evaporative Condenser, Adiabatic Efficient Air Cooler, Air Cooler
Production Lines1
Production MachinesBending Machine, Forming Machine, Laser Cutting Machine, Pipe Bending Machine, Pipe Making Machine, Sawing Machine, Ultrasonic Flaw Detector, Work Vibration Meter, Airflow Tester
QA/QC inspectors2 people
Inspection Type for Finished Products100% inspection(Visual inspection & Function inspection)
Inspection Method for Finished ProductsHave instructions and uniformly followed
R&D Engineers7 people
Traceability of Raw MaterialsYes
Own BrandYes

Our Industry Experience & Global Business Record

Year of Establishment2026-01-12
Main MarketsNorth America, Europe, Domestic
Repeat Buyers Choice30%~50%
Number of Foreign Trading Staff10
Overseas Agent/BranchNo
New Products Launched in Last yearNo

Our Certifications, Standards & Industry Recognition

Management System CertificationISO9001:2015, ISO14001, ISO45001:2018
Cooperated with Fortune 500Yes

Product Q&A

Q:What is wet-dry operation in a closed cooling tower?
A:
The tower can use evaporative cooling when higher heat rejection is required and dry air cooling when ambient conditions allow, reducing water use.
Q:Why is dry operation useful in winter?
A:
When ambient temperatures are sufficiently low, heat can be rejected without spray water, reducing water consumption and helping protect the system from freezing.
Q:Can the tower automatically adjust cooling capacity?
A:
Variable air volume control can adjust airflow according to cooling demand. The control strategy can be customized for the project.
Q:Is the process fluid exposed to the atmosphere?
A:
No. The process fluid remains inside the closed heat exchange circuit and is separated from spray water and ambient air.
Q:What factors determine the cooling tower size?
A:
Sizing depends on heat load, process flow rate, inlet and outlet temperatures, site wet-bulb temperature, fluid properties and required operating conditions.

Send Inquiry

*To:Shandong Casen Heat Transfer Technology Co., Ltd. Qingdao BranchShandong Casen Heat Transfer Technology Co., Ltd. Qingdao Branch
*Content:
0/4000

Supplier replies will be sent to your registered email

You may also like

Data Center Cooling System Closed Water Cooling Tower
Made-in-China.com