Powered by Made-in-China.com
CT Angle Error Ratio Error Tester Current Tansformer CT Vt Analyzer Epcp-III
US$1,000.00-4,000.00
1 Set
Product profile
Customization
AvailableType
Universal Testing MachineDisplay
LCDModel NO.
EPCP-IIIControl
Computer ControlWeight
Less Than 22kgPower Source
220V or 120V at CustomizedSingle Machine Output
0-2500vrms, 5kVA (Maximum Setting Value 20A)Primary Current Output
0-1000AExcitation Accuracy
Less Than 0.5% (0.2%*Reading+0.3%*Range)Secondary Winding Resistance Measurement
0.1-300ohmSecondary Real Load Measurement
5-500vaPhase Measurement (Angle Difference)
4minResolution
0.1minCT Ratio Measurement Range
Less Than 25000A/5A(5000A/1A)PT Ratio Measurement Range
Less Than 500kvOperating Temperature
-10~+40degreeRelative Humidity
Less 90rh%Altitude
Less Than 1000mCurrent Transformer (CT)
Auto Calculation of Knee Point ValuePolarity
YesTransport Package
Plywood Case with Warter Proof PlasticSpecification
410mm*260mm*340(mm)Trademark
EP Hipot ElectricOrigin
ChinaHS Code
9030820000Production Capacity
2000/YearKey features
Portable and Lightweight Design: Weighs less than 22kg, making it highly portable for convenient field testing.
Comprehensive CT/PT Analysis: Supports full function testing for CT and PT including excitation, ratio, and polarity tests.
High Precision Measurement: Excitation accuracy is less than 0.5%, ensuring reliable and precise test results.
Intelligent Data Management: Stores 3000 sets of data with power failure protection and supports USB transfer to PC.
Automatic Curve Calculation: Automatically calculates CT/PT inflection points and 5% and 10% error curves.
Customizable Power Source: Power source can be customized to 220V or 120V to meet different regional standards.
Instant On-Site Printing: Features a fast printer that directly prints test results on site for immediate records.
User-Friendly Interface: Equipped with a large LCD screen and graphical interface with intelligent operation prompts.
Company profile
CertifiedBusiness Type: Manufacturer/Factory & Trading Company CertifiedR&D Capacity: ODM Service Available & OEM Service Available CertifiedCustomization Options: Customization from Samples, Customization from Designs, etc. CertifiedExport Year: 8 Years CertifiedNearest Port: Shanghai Port; Ningbo Port; Guangzhou Port; Shenzhen PortAverage Response Time: ≤1.54h
AI-Powered supplier vetting
SummaryThe supplier is a combined manufacturing and technical-service company focused on electrical instrumentation and related equipment. It reports three production lines and annual output of 2,000 sets each for three listed testing products, with a stated off-peak lead time within 15 workdays. It offers customization from designs and samples, including full and flexible customization. The supplier describes global after-sales support through qualified service centers, but service procedures lack written records. Major weaknesses include no stated quality assurance, no supplier-management certification, no in-stock capability, no overseas warehouse or showroom, and no available SDK. R&D evidence is limited: one year of R&D engineer experience is reported, while the supplier is explicitly not identified as a professional technical supplier and does not provide 3D software design. No customer cases are provided, and financial information is insufficient for assessment.
CertificationsThe supplier-management certification field is recorded as NIL. In addition, the quality-control assessment states that no quality assurance is provided, indicating no explicit certification or formal quality-assurance evidence in the provided data.
R&D capabilityInnovation evidence is limited: the supplier reports no available SDK, does not provide 3D software design services, and is not classified as a professional technical supplier. It does offer several forms of design-based customization, but this does not establish strong independent innovation capability.
Production capacityThe supplier operates three lines—assembling, testing, and winding—and reports annual output of 2,000 sets each for a Transformer Ohmmeter, AC VLF Hipot Test Set, and Capacitance & Factor Dissipation Tester. It also has valid manufacturing-capacity contracts with each related subcontractor and reports an off-peak lead time within 15 workdays, although no in-stock capability is available.
Customization capabilityThe supplier explicitly supports customization from designs and samples, full customization, flexible customization, and minor customization. This is direct evidence of broad customization capability across multiple input formats and levels of modification.
Product Q&A
Q:What is the maximum output capacity of the EPCP-III?
A:
The single machine output is 0-2500Vrms, 5kVA, with a maximum setting value of 20A.
Q:Can this device test both CT and PT simultaneously?
A:
Yes, it can complete excitation and transformation ratio polarity tests for both CT and PT in one test.
Q:How much data can the device store?
A:
It can save 3000 sets of test data, which will not be lost even after a power failure.
Q:Is the device suitable for field testing?
A:
Yes, it is small and lightweight (less than 22kg), making it very conducive to field testing.
Q:What is the accuracy of the excitation characteristic test?
A:
The excitation accuracy is less than 0.5%, calculated as 0.2%*Reading + 0.3%*Range.
Send Inquiry
*To:
EP HIPOT ELECTRIC CO., LTD.
EP HIPOT ELECTRIC CO., LTD.*Content:
Supplier replies will be sent to your registered email
You may also like
CT PT Angle Error Ratio Error Tester Tansformer Analyzer GDHG-103
US$2,954.00-4,924.00
1 Piece(MOQ)
Current Potential Transformer Analyzer / CT Vt Tester / CT PT CVT Analyzer
US$6,600.00
1 sets(MOQ)
Transformer CT PT Tester, Current Transformer Analyzer CT Meter
US$8,000.00-11,000.00
1 Piece(MOQ)
Current Transformer CT PT Analyzer Portable Volt Ampere Characteristic Ratio Polarity Tester
US$3,599.00-3,699.00
1 sets(MOQ)
Transformer Volt Ampere Ratio Polarity Comprehensive Characteristic Tester CT /PT/VT Analyzer
US$6,775.00-7,400.00
1 sets(MOQ)
Current Transformer Tester CT PT Analyzer Voltage Transformer Analyzer
US$6,000.00-8,500.00
1 Piece(MOQ)
Wide Range CT/PT Transformer Ratio Analyzer and Insulation Tester
Negotiable
1 Piece(MOQ)
Multi-Function High Precision Current Transformer CT PT Vt Volt-Ampere Characteristic Analyzer Price
US$6,775.00-7,400.00
1 sets(MOQ)
CT PT Analyzer CT Parameter Automatic Calculation Current Voltage Transformer Tester
US$1,375.00-7,315.00
1 Set(MOQ)
HV HIPOT High Accuracy CT PT Analyzer Excitation Current Secondary Burden Tester
US$5,000.00-7,500.00
1 Piece(MOQ)
Gfuve Portable CT Current Transformer Analyzer with 50kv Excitation Knee Point
US$20,000.00-35,000.00
1 Set(MOQ)
Hv Current Transformers Volt-Ampere Characteristic Tester Huayi Electric CT Analyzer
US$1,500.00-2,000.00
1 sets(MOQ)
CT PT Analyzer Transformer Volt-Ampere Characteristic Tester for Current & Voltage Transformer Test
US$1,375.00-7,315.00
1 Set(MOQ)
Price Automatic Current Transformer Analyser CT PT Characteristics Analyzer
US$1,000.00-4,000.00
1 Set(MOQ)
High Performance Automatic Variable Frequency Current Transformer CT PT Analyzer PT CT Exciting Curve Analyzer
US$2,000.00-4,000.00
1 Set(MOQ)
Industrial CT PT Analyzer Support 1~40000 Transformation Ratio Transformer Calibration Tester
US$1,375.00-7,315.00
1 Set(MOQ)
Manufacture Current Transformer and Power Transformer Tester CT PT Analyzer
US$7,742.00
1 Piece(MOQ)
High Accuracy CT PT Analysis Current Transformer Polarity Tester CT PT Characteristics Analyzer
US$2,000.00-6,000.00
1 Piece(MOQ)