Accuracy Grade

1

Load Way

Electronic Load

Model NO.

GD-610B

Loading Method

Dynamic Load

Display

Digital

Control

Computer Control

Weight

0-100Kg

Power Source

AC220V

Center Frequency

40kHz±2Hz

Discharge Mode

Pinpoint Arc Discharge

Discharge Interval

4mm

Voltage

AC 10kV Distance 18m

Working Voltage

7.4V (lithium-ion batteries*2PCS)

Dimension

250*125*140mm

Use Temperature

-30-60centigrade

Whole dimension

470*340*420mm

Humidity

(0~100)%RH

Complete packing weight

7.18kg

Transport Package

Wooden Case

Specification

ISO, SGS

Trademark

HV Hipot

Origin

Wuhan China

HS Code

9031803100

Production Capacity

2000PCS/Year

Key features

100% Accuracy Rate: Laser locking technology ensures precise positioning of deteriorated insulators.
Long-Distance Detection: Detects faults up to 50 meters away for voltages ranging from 35kV to 500kV.
Dual Indication System: Combines stereo headphone audio feedback with LCD visual intensity display.
Automatic Low Voltage Alarm: Shuts off automatically when battery voltage is low to protect the instrument.
High Sensitivity: Detects leakage currents as low as 1mA on live insulators.
Laser Aiming Function: 650nm laser output with 0.4mrad divergence for accurate target locking.
Smart Battery Management: Lithium-ion battery supports 1000 charging cycles with intelligent charging system.
Strong Anti-Interference: Advanced microcomputer processing mode filters noise for clear signal detection.

Company profile

CertifiedBusiness Type: Manufacturer/Factory & Trading Company CertifiedR&D Capacity: ODM Service AvailableExport Year: 2011-07-01 CertifiedNearest Port: Wuhan PortAverage Response Time: ≤1.36h CertifiedTerms of Payment: LC, T/T

AI-Powered supplier vetting

SummaryHV Hipot Electric Co., Ltd. is a China-based factory and limited company in Wuhan, Hubei, established in 2006 according to the company profile, while another description states operations began in 2003. It manufactures high-voltage testing and related electrical measurement equipment, including AC/DC hipot testers, partial-discharge testers, and circuit-breaker testers. The supplier reports ISO9001:2015 and ISO14001:2015 certifications, three production lines, 6–10 quality-control staff, and eight years of R&D-engineer experience; another statement reports 18 technicians in its R&D team. It serves multiple overseas markets and accepts LC and T/T payment terms, with stated one-month lead times in both peak and off-peak seasons. Evidence supports established technical and manufacturing capabilities, but after-sales service, customization, and specific customer cases are not sufficiently documented.
Supplier typeThe supplier is identified as a limited company, a factory, and a manufacturing enterprise located in Wuhan, China. Its business focuses on instruments, meters, electrical and electronic products, particularly high-voltage testing equipment.
CertificationsThe supplier explicitly reports ISO9001:2015 and ISO14001:2015 certificates, while another company description confirms ISO9001 quality management certification and high-tech enterprise qualifications. These statements provide direct evidence of formal quality and environmental management credentials.
R&D capabilityThe supplier reports successive development of multiple high-voltage testing products, participation in high-voltage and energy-saving projects with State Grid-related organizations, research institutions, and Wuhan University, and an R&D team described as 18 technicians. These are explicit indicators of product-development and technical innovation capability.
Production capacityThe supplier operates as a factory with three production lines, 6–10 quality-control staff, a 2,712 m² manufacturing plant, and stated one-month order fulfillment in both peak and off-peak seasons. It also reports self-operated import and export rights and serves several overseas markets, supporting a positive assessment of production and delivery capability.

Product Q&A

Q:What is the detection range for different voltage levels?
A:
The device detects up to 18 meters at 10kV, 25 meters at 35kV, and 50 meters at 110kV to 500kV.
Q:Can this device detect faults without cutting power?
A:
Yes, it is designed to detect and locate faults in power stations and substations without interrupting power supply.
Q:What types of insulator faults can be detected?
A:
It detects unknown flashovers, leakage currents, composite faults, oxidation discharge, bad switch contacts, and pollution flashovers.
Q:How does the device indicate the detected sound?
A:
It provides dual indication through stereo headphones for audio and an LCD display for visual intensity indication.
Q:What is the battery life and charging capability?
A:
It uses a lithium-ion battery capable of 1000 charging cycles with an intelligent charging system that auto-stops when full.

Send Inquiry

*To:HV Hipot Electric Co., Ltd.HV Hipot Electric Co., Ltd.
*Content:
0/4000

Supplier replies will be sent to your registered email

You may also like

HVHIPOT New Arrival GD-610B Insulator Fault Detector
Made-in-China.com
GD-610B Long Distance Insulator Fault Detector

GD-610B Long Distance Insulator Fault Detector

US$2,000.00-5,000.00
1 Piece(MOQ)
Made-in-China.com
Portable Underground Power Cable Fault Detector
Made-in-China.com