SourcingAI
Try for free
Powered by Made-in-China.com
GDHG-103 CT PT Calibrator Transformer Calibration Device
US$2,954.00-4,890.00
1 Piece

Product profile

Customization

Available

Application

Electronic, Instrument

Type

CT/PT

Model NO.

GDHG-103

Phase

Single

Operation Condition

Indoor & on-Site

Usage

Measurement

Winding Form

Multilayer Honeycomb Type

Insulating Medium

Insulating Oil

Installation

Portable Type

Magnetic Circuit Structure

Combined Type

Voltage Transformation Principle

Electromagnetic Type

Power Supply

AC220V±10%, 50Hz

Output Current

0-1000A

Accuracy of Excitation

0.5%(0.2%*The Reading+0.3%*Range)

Accuracy of Angular Error

4min

Accuracy of Ratio Error

0.05%

Dimension

440mm*340mm*380mm

Weight

35kg

Transport Package

Wooden Case

Specification

ISO, SGS

Trademark

HV Hipot

Origin

Wuhan China

HS Code

9030841000

Production Capacity

7000PCS/Year

Key features

High Precision Calibration: Achieves 0.05% ratio error and 4min angular error for accurate CT/PT testing.
Wide Measurement Range: Covers accuracy classes 0.01 to 10 with in-phase component 0.0001-200%.
Automatic Operation: Features auto polarity judgment, range switching, and difference value measurement.
Data Management: 320*240 LCD display with PC connection, data saving, and printing capabilities.
Versatile Compatibility: Supports CT secondary currents 5A/1A and PT voltages 100V/150V.
Portable Design: Compact dimensions 440*340*380mm and weight 35kg for indoor and on-site use.
Customization Available: ODM service available with customizable power supply and output current options.

Company profile

CertifiedBusiness Type: Manufacturer/Factory & Trading Company CertifiedR&D Capacity: ODM Service AvailableExport Year: 2011-07-01 CertifiedNearest Port: Wuhan PortAverage Response Time: ≤2.51h CertifiedTerms of Payment: LC, T/T

AI-Powered supplier vetting

SummaryHV Hipot Electric Co., Ltd. is a China-based factory and limited company in Wuhan, Hubei, established in 2006 according to the company profile, while another description states operations began in 2003. It manufactures high-voltage testing and related electrical measurement equipment, including AC/DC hipot testers, partial-discharge testers, and circuit-breaker testers. The supplier reports ISO9001:2015 and ISO14001:2015 certifications, three production lines, 6–10 quality-control staff, and eight years of R&D-engineer experience; another statement reports 18 technicians in its R&D team. It serves multiple overseas markets and accepts LC and T/T payment terms, with stated one-month lead times in both peak and off-peak seasons. Evidence supports established technical and manufacturing capabilities, but after-sales service, customization, and specific customer cases are not sufficiently documented.
Supplier typeThe supplier is identified as a limited company, a factory, and a manufacturing enterprise located in Wuhan, China. Its business focuses on instruments, meters, electrical and electronic products, particularly high-voltage testing equipment.
CertificationsThe supplier explicitly reports ISO9001:2015 and ISO14001:2015 certificates, while another company description confirms ISO9001 quality management certification and high-tech enterprise qualifications. These statements provide direct evidence of formal quality and environmental management credentials.
R&D capabilityThe supplier reports successive development of multiple high-voltage testing products, participation in high-voltage and energy-saving projects with State Grid-related organizations, research institutions, and Wuhan University, and an R&D team described as 18 technicians. These are explicit indicators of product-development and technical innovation capability.
Production capacityThe supplier operates as a factory with three production lines, 6–10 quality-control staff, a 2,712 m² manufacturing plant, and stated one-month order fulfillment in both peak and off-peak seasons. It also reports self-operated import and export rights and serves several overseas markets, supporting a positive assessment of production and delivery capability.

Product Q&A

Q:What is the accuracy of the GDHG-103 calibrator?
A:
The device offers an accuracy of 0.05% for ratio error and 4min for angular error.
Q:Which CT/PT classes can be calibrated?
A:
It is mainly used to calibrate CT/PT with accuracy class 0.01 to class 10.
Q:Does the device support data storage and printing?
A:
Yes, it features a 320*240 LCD screen, PC connection, data saving, and printing functions.
Q:Is the device portable for on-site use?
A:
Yes, it is a portable type weighing 35kg with dimensions 440*340*380mm.
Q:What are the available secondary rated values?
A:
CT secondary rated current is 5A and 1A; PT secondary rated voltage is 100V, 100/3V, and 150V.