Model NO.

GDYD-3/15

Type

Withstand Voltage Test Set

Load Way

Electronic Load

Loading Method

Dynamic Load

Display

Digital

Control

Manual Control

Power Source

AC220V ± 10%

Input

AC220V ± 10%

Frequency

50Hz ± 1

Output

0-15kV, 200mA AC RMS

Rating

100%Rated-1minute , 50%-continuous

Capacity

3kVA

HV Source

Epoxy resin cast HV transformer

Output control

Manual control

Transport Package

Wooden Case

Specification

ISO, SGS

Trademark

HV Hipot

Origin

Wuhan China

HS Code

9030332000

Production Capacity

2000PCS/Year

Key features

High Voltage Output: Provides 0-15kV AC RMS output with 200mA capacity for dielectric testing.
Wide Timing Range: Features a new time relay with an adjustable range from 1 second to 99 hours.
Digital Monitoring: Includes digital display for voltage, current, and status indicators like zero and power.
Safety Protections: Equipped with over-current protection, zero-starting protection, and sound/light alarms.
Compact Design: Lightweight and small size, making it easy to move and operate in various settings.
High Accuracy: Ensures precise testing with voltage and current accuracy within 1.5% of full scale.
Customizable Options: Input voltage and frequency can be customized to meet specific client requirements.
Reliable Transformer: Utilizes an epoxy resin cast HV transformer for dry type testing reliability.

Company profile

CertifiedBusiness Type: Manufacturer/Factory & Trading Company CertifiedR&D Capacity: ODM Service AvailableExport Year: 2011-07-01 CertifiedNearest Port: Wuhan PortAverage Response Time: ≤3.09h CertifiedTerms of Payment: LC, T/T

AI-Powered supplier vetting

SummaryHV Hipot Electric Co., Ltd. is a China-based factory and limited company in Wuhan, Hubei, established in 2006 according to the company profile, while another description states operations began in 2003. It manufactures high-voltage testing and related electrical measurement equipment, including AC/DC hipot testers, partial-discharge testers, and circuit-breaker testers. The supplier reports ISO9001:2015 and ISO14001:2015 certifications, three production lines, 6–10 quality-control staff, and eight years of R&D-engineer experience; another statement reports 18 technicians in its R&D team. It serves multiple overseas markets and accepts LC and T/T payment terms, with stated one-month lead times in both peak and off-peak seasons. Evidence supports established technical and manufacturing capabilities, but after-sales service, customization, and specific customer cases are not sufficiently documented.
Supplier typeThe supplier is identified as a limited company, a factory, and a manufacturing enterprise located in Wuhan, China. Its business focuses on instruments, meters, electrical and electronic products, particularly high-voltage testing equipment.
CertificationsThe supplier explicitly reports ISO9001:2015 and ISO14001:2015 certificates, while another company description confirms ISO9001 quality management certification and high-tech enterprise qualifications. These statements provide direct evidence of formal quality and environmental management credentials.
R&D capabilityThe supplier reports successive development of multiple high-voltage testing products, participation in high-voltage and energy-saving projects with State Grid-related organizations, research institutions, and Wuhan University, and an R&D team described as 18 technicians. These are explicit indicators of product-development and technical innovation capability.
Production capacityThe supplier operates as a factory with three production lines, 6–10 quality-control staff, a 2,712 m² manufacturing plant, and stated one-month order fulfillment in both peak and off-peak seasons. It also reports self-operated import and export rights and serves several overseas markets, supporting a positive assessment of production and delivery capability.

Product Q&A

Q:What is the output voltage and current capacity?
A:
The system provides an output of 0-15kV AC RMS with a current capacity of 200mA.
Q:What safety features are included?
A:
It includes over-current protection, zero-starting protection, and sound and light alarms.
Q:What is the timing range for the test?
A:
The timing range is adjustable from 1 second to 99 hours using a new type time relay.
Q:Is customization available for input parameters?
A:
Yes, input voltage and frequency can be customized according to specific requirements.
Q:What is the accuracy of the voltage and current measurements?
A:
Both voltage and current accuracy are within 1.5% of full scale (F.S).

Send Inquiry

*To:HV Hipot Electric Co., Ltd.HV Hipot Electric Co., Ltd.
*Content:
0/4000

Supplier replies will be sent to your registered email

You may also like

Generator Dielectric Strengh Resonance Test Systems (RTS)
Made-in-China.com
AC Dielectric Resonance Test System

AC Dielectric Resonance Test System

US$2,000.00-20,000.00
1 Set(MOQ)
Made-in-China.com