HVHIPOT Automatic Power Transformer Protection Demagnetization Tester GD8000
US$2,647.00-3,823.00
1 Piece

Product profile

Customization

Available

After-sales Service

Yes

Warranty

1 year

Model NO.

GD8000

Degaussing current

5A, 2A, 200mA, 5mA (Can be customized)

Degaussing way

Manual or Automatic mode

Degaussing

Maunal:4min/time; automatic 9min/time

Degaussing effect

Over 90%/times

Demagnetization progress

0-100%

Power Supply

AC 220V

Power Frequency

50Hz

Environment Temperature

-20 centigrade to +50 centigrade

Transport Package

Plywood Case

Specification

ISO, SGS

Trademark

HV Hipot

Origin

China

HS Code

9030899090

Production Capacity

1000 Pieces/Year

Key features

Patented DC Frequency Attenuation: Uses patented technology to eliminate residual magnetism hazards effectively.
Single-Phase Degaussing Efficiency: Only degauss B phase to complete the whole work for three-phase transformers.
Fast and Effective Degaussing: Manual mode takes 4 mins, automatic over 90% effect per time.
Customizable Degaussing Current: Current options: 5A, 2A, 200mA, 5mA, with customization available.
Direct Cable Compatibility: Current lines of DC resistance testing can be directly used for easy matching.
Portable Field Design: Small size and light weight (5kg), most suitable for field testing.
Automatic Data Processing: Features automatic judgment and 16AD data collection and processing.
Wide Voltage Application: Suitable for 35kV and above, especially large capacity 330kV+ transformers.

Company profile

CertifiedBusiness Type: Manufacturer/Factory & Trading Company CertifiedR&D Capacity: ODM Service AvailableExport Year: 2011-07-01 CertifiedNearest Port: Wuhan PortAverage Response Time: ≤4.25h CertifiedTerms of Payment: LC, T/T

AI-Powered supplier vetting

SummaryHV Hipot Electric Co., Ltd. is a China-based factory and limited company in Wuhan, Hubei, established in 2006 according to the company profile, while another description states operations began in 2003. It manufactures high-voltage testing and related electrical measurement equipment, including AC/DC hipot testers, partial-discharge testers, and circuit-breaker testers. The supplier reports ISO9001:2015 and ISO14001:2015 certifications, three production lines, 6–10 quality-control staff, and eight years of R&D-engineer experience; another statement reports 18 technicians in its R&D team. It serves multiple overseas markets and accepts LC and T/T payment terms, with stated one-month lead times in both peak and off-peak seasons. Evidence supports established technical and manufacturing capabilities, but after-sales service, customization, and specific customer cases are not sufficiently documented.
Supplier typeThe supplier is identified as a limited company, a factory, and a manufacturing enterprise located in Wuhan, China. Its business focuses on instruments, meters, electrical and electronic products, particularly high-voltage testing equipment.
CertificationsThe supplier explicitly reports ISO9001:2015 and ISO14001:2015 certificates, while another company description confirms ISO9001 quality management certification and high-tech enterprise qualifications. These statements provide direct evidence of formal quality and environmental management credentials.
R&D capabilityThe supplier reports successive development of multiple high-voltage testing products, participation in high-voltage and energy-saving projects with State Grid-related organizations, research institutions, and Wuhan University, and an R&D team described as 18 technicians. These are explicit indicators of product-development and technical innovation capability.
Production capacityThe supplier operates as a factory with three production lines, 6–10 quality-control staff, a 2,712 m² manufacturing plant, and stated one-month order fulfillment in both peak and off-peak seasons. It also reports self-operated import and export rights and serves several overseas markets, supporting a positive assessment of production and delivery capability.

Product Q&A

Q:What is the purpose of the GD8000 tester?
A:
It eliminates residual magnetism hazards after DC resistance tests, protecting transformers from inrush current and ensuring safe commissioning.
Q:How long does the degaussing process take?
A:
Manual mode takes 4 minutes per time, while automatic mode takes 9 minutes per time.
Q:What is the degaussing effect efficiency?
A:
The degaussing effect is obvious, achieving over 90% efficiency per time in automatic mode.
Q:Can the degaussing current be customized?
A:
Yes, the degaussing current can be customized. Standard options include 5A, 2A, 200mA, and 5mA.
Q:What is the warranty period for this device?
A:
The product comes with a 1-year warranty.

Send Inquiry

*To:HV Hipot Electric Co., Ltd.HV Hipot Electric Co., Ltd.
*Content:
0/4000

Supplier replies will be sent to your registered email

You may also like

5A Automatic Transformer Demagnetization Tester

5A Automatic Transformer Demagnetization Tester

US$6,400.00-9,000.00
1 Piece(MOQ)
Made-in-China.com