SourcingAI
Try for free
Powered by Made-in-China.com
Oil Resistivity Tester Dielectric Strength Dissipation Factor Test Equipment
US$5,000.00-8,000.00
1 Piece

Product profile

Customization

Available

Type

Universal Testing Machine

Accuracy Grade

1

Model NO.

GD6100C

Load Way

Electronic Load

Loading Method

Dynamic Load

Display

Digital

Control

Computer Control

Weight

0-100Kg

Power Source

AC220V

Oil Cylinder Position

Top

Voltage Supply

AC 220V±10%

Power Frewuency

50Hz/60Hz ±1%

Capacitance Measurement

5PF~200PF

Dielectric Loss Factor

0.00001~100

Capacitance Accuracy

± (1% of Reading+0.5PF)

Transport Package

Carton or Wooden Case

Specification

ISO, SGS

Trademark

HV Hipot

Origin

Wuhan, China

HS Code

9030332000

Production Capacity

1000PCS/Year

Key features

Three-Electrode Test Cell: Adopts GB/T5654-2007 standard with 2mm spacing to eliminate stray capacitance and leakage effects.
PID Temperature Control: Uses medium frequency induction heating with PID algorithm for uniform heating and precise temperature control.
High Stability Capacitor: Internal SF6 gas-filled capacitor ensures accuracy is not affected by ambient temperature or humidity.
Anti-Interference Power: AC-DC-AC conversion prevents mains voltage fluctuations from affecting measurement accuracy.
Comprehensive Protection: Features over-voltage, over-current, short-circuit protection, and sensor failure warnings.
Automatic Data Management: Built-in clock saves test date/time; automatically stores and prints results with LCD display.
Easy Maintenance Design: Equipped with oil drainage solenoid switch for easy emptying and rinsing without removing the cell.

Company profile

CertifiedBusiness Type: Manufacturer/Factory & Trading Company CertifiedR&D Capacity: ODM Service AvailableExport Year: 2011-07-01 CertifiedNearest Port: Wuhan PortAverage Response Time: ≤3.74h CertifiedTerms of Payment: LC, T/T

AI-Powered supplier vetting

SummaryHV Hipot Electric Co., Ltd. is a China-based factory and limited company in Wuhan, Hubei, established in 2006 according to the company profile, while another description states operations began in 2003. It manufactures high-voltage testing and related electrical measurement equipment, including AC/DC hipot testers, partial-discharge testers, and circuit-breaker testers. The supplier reports ISO9001:2015 and ISO14001:2015 certifications, three production lines, 6–10 quality-control staff, and eight years of R&D-engineer experience; another statement reports 18 technicians in its R&D team. It serves multiple overseas markets and accepts LC and T/T payment terms, with stated one-month lead times in both peak and off-peak seasons. Evidence supports established technical and manufacturing capabilities, but after-sales service, customization, and specific customer cases are not sufficiently documented.
Supplier typeThe supplier is identified as a limited company, a factory, and a manufacturing enterprise located in Wuhan, China. Its business focuses on instruments, meters, electrical and electronic products, particularly high-voltage testing equipment.
CertificationsThe supplier explicitly reports ISO9001:2015 and ISO14001:2015 certificates, while another company description confirms ISO9001 quality management certification and high-tech enterprise qualifications. These statements provide direct evidence of formal quality and environmental management credentials.
R&D capabilityThe supplier reports successive development of multiple high-voltage testing products, participation in high-voltage and energy-saving projects with State Grid-related organizations, research institutions, and Wuhan University, and an R&D team described as 18 technicians. These are explicit indicators of product-development and technical innovation capability.
Production capacityThe supplier operates as a factory with three production lines, 6–10 quality-control staff, a 2,712 m² manufacturing plant, and stated one-month order fulfillment in both peak and off-peak seasons. It also reports self-operated import and export rights and serves several overseas markets, supporting a positive assessment of production and delivery capability.

Product Q&A

Q:What standards does the test cell follow?
A:
The test cell adopts the three-electrode structure according to national standard GB/T5654-2007, with electrode spacing of 2mm.
Q:How is the temperature controlled during testing?
A:
The instrument uses medium frequency induction heating with a PID temperature control algorithm, ensuring uniform heating and strict temperature control within the error range.
Q:Does the instrument protect against electrical faults?
A:
Yes, it features perfect protection functions including over-voltage, over-current, and high-voltage short circuit protection, which quickly cut off pressure and issue warnings.
Q:What are the voltage settings for AC and DC tests?
A:
AC test voltage is 500-2200V (continuously adjustable, 50Hz), and DC test voltage is 0-500V (continuously adjustable).
Q:Can the instrument operate on generator power?
A:
Yes, the AC test power supply uses AC-DC-AC conversion, effectively preventing fluctuations in mains voltage and frequency, allowing proper operation even with a generator.

Send Inquiry

*To:HV Hipot Electric Co., Ltd.HV Hipot Electric Co., Ltd.
*Content:
0/4000

Supplier replies will be sent to your registered email

You may also like