SourcingAI
Try for free
Powered by Made-in-China.com
Pneumatically Operated Gate Valves DN300 Cast Iron for HVAC
US$25.00
1 Piece
Sample price:US$25.00/piece.Request sample

Product profile

Customization

Available

Media

Water, Sewage, Air, Gas, Neutral Fluids

Type

Floating,Fixed,Flexible,Tee, V Type Ball Valve

Material

Carbon Steel,Stainless Steel,Brass,Other

Connection Form

Clamp, Flange, Wafer, Welding,etc

Pressure

Ordinary Temperature

Actuator

Pneumatic Actuator/ Electrical Actuator/ Manual

Seal Surface

Wedge Gate Valve

Thread Position of Valve Rod

Customized

Usage

Regulation, Safety, Emptying, Drain, Temperature Control, Flow Control

Standard

GB, DIN, JIS, ANSI

Application

Industrial Usage, Water Industrial Usage, Household Usage

Customize Support

OEM,ODM

Body Material

Cast Iron, Cast Steel, Stainless Steel

Operation

Pneumatic Actuator/ Electrical Actuator/ Manual

Valve Type

Ball Valve, Butterfly Valve, Angle Seat Valve, etc

Transport Package

Plywood Case / Carton with Pallet

Specification

DN15~DN800

Trademark

KINKO

Origin

Zhejiang, China

Production Capacity

500000PCS/Year

Key features

Compact and Lightweight Design: Rack and pinion design ensures compact and lightweight structure for easy installation.
High Cycle Life: Features low-friction bearings on all moving surfaces for extended operational life.
Corrosion Resistant: Anodized rigid body and PTFE coated end covers provide superior corrosion resistance.
Safety Spring Protection: Safety springs prevent accidental movement risks during maintenance operations.
Modular Design: Uses same body and end caps for both dual-acting and spring return versions.
ISO Mounting Pattern: Standard ISO mounting pattern ensures compatibility with various accessories.
Adjustable Stop Positions: Adjustable stops allow precise control for both open and closed positions.
Smooth Operation: Motorized gear teeth provide longer life and smoother operation.

Company profile

Zhejiang Kinko-Fluid Equipment Co., Ltd.
Importers and ExportersSelf-brandedManagement CertificationR&D Capabilities
CertifiedBusiness Type: Manufacturer/Factory & Trading Company CertifiedR&D Capacity: ODM Service Available & OEM Service AvailableExport Year: 2016-03-01 CertifiedNearest Port: Ningbo Port, Shanghai PortAverage Response Time: ≤1.37h CertifiedTerms of Payment: LC, T/T, D/P, etc.

About Our Factory & Business Background

AddressBldg C3-1, Wanyang Technology City, No. 2999 Nanyang Ave. Yaoxi St, Wenzhou, Zhejiang, China
Number of Employees22
Registered Capital20,000,000 RMB
International Commercial Terms(Incoterms)FOB, EXW, CFR, CIF, DDP
Average Lead TimePeak Season Lead Time: one month Off Season Lead Time: within 15 workdays

Our Production Capability & Technical Expertise

Main ProductsPneumatic Actuator, Electrical Actuator, Pneumatic Valves, Electric Valves, Automatic Control Valves, Angle Seat Valves, Piston Valves, Limit Switch Box, Positioner, Frl Accessories
R&D Engineers3 people
Own BrandYes

Our Industry Experience & Global Business Record

Year of Establishment2019-05-24
Main MarketsNorth America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe
Number of Foreign Trading Staff8
Overseas Agent/BranchNo

Product Q&A

Q:What causes leakage in gate valves and how can it be prevented?
A:
Gate valve leakage falls into two main categories: internal leakage (failure to seal tightly) and external leakage (leakage from the valve body or packing gland). Internal leakage is usually caused by worn sealing surfaces, deformed sealing gaskets, or debris trapped between the sealing faces. External leakage is often due to aged packing or loose mounting bolts.
Q:Why does a gate valve become stiff or stuck during operation?
A:
Common causes include: Stem rust due to lack of lubrication Sediment buildup from debris in the medium Weld slag or foreign matter left in the pipeline during installation
Q:Can a gate valve be used for flow regulation?
A:
No. Gate valves are designed strictly for on/off service fully open or fully closed. Using a gate valve in a partially open position for throttling will cause severe erosion and wear of the sealing surfaces, leading to leakage and premature failure. For flow regulation, please consider globe valves or control valves
Q:What are the operational precautions for gate valves?
A:
Avoid excessive force: Over-tightening the handwheel can damage the stem or gate. High-temperature applications: After closing a valve under high-temperature conditions, thermal contraction may cause components to seize as they cool. It is advisable to slightly loosen the handwheel after cooling.
Q:What is the difference between metal-seated and soft-seated gate valves
A:
Metal-seated gate valve: Features metal-to-metal sealing surfaces, resistant to high temperature and high pressure. Suitable for demanding services such as steam, oil, and gas.

Send Inquiry

*To:Zhejiang Kinko-Fluid Equipment Co., Ltd.Zhejiang Kinko-Fluid Equipment Co., Ltd.
*Content:
0/4000

Supplier replies will be sent to your registered email

You may also like