SourcingAI
Try for free
Powered by Made-in-China.com
Suyzeko Diabetes Treatment 650nm Semiconductor Cold Laser Therapy Watch
US$168.00
20-99 Pieces
US$125.00
100-999 Pieces
US$98.00
1,000+ Pieces
Sample price:US$258.00/piece.Request sample

Product profile

Customization

Available

Type

Laser Therapy

Function

Improve Blood Circulation

Model NO.

GY-L2

Theory

Laser

Certification

CE

LCD Display

With LCD Display

Group

Adult

Terminal Laser Probe

10 Laser Beams for Watch, 2 Nasal Cavity Laser Bea

Laser Medium

Gaa/as Semiconductor

LED Light

450nm

Laser Emission Wavelength

650nm

Laser Output Power

2-5MW for Each Laser Probe

Laser Operating Voltage

3.0 V

Environment Temperature

-20degree ~ 40degree

Power Source Use

1600 Ma Lithium Battery

Product Packing

1PC/Box, 19*12*13cm

Warranty

1 Year

Atmospheric Pressure

86kpa-106kpa

OEM/Oed

Support

Fixed Time Range

10-60 Minutes Adjustable

Input Voltage of Power

100-240 V Switching Adapter

Application

Home

Transport Package

Carton Package

Specification

19*12*13cm

Trademark

SSCH/Suyzeko

Origin

China

Production Capacity

100pieces/Month

Key features

3-in-1 Laser Therapy: Combines acupuncture, local pain therapy, and external blood irradiation for comprehensive treatment.
650nm Cold Laser: Uses low-energy 650nm laser and 450nm LED light to improve blood circulation and reduce viscosity.
Multi-Application Probes: Includes nasal cavity, ear, and pain relief pad probes for versatile home and clinical use.
OEM/ODM Support: Supports custom logo and terminal laser probe configurations for personalized branding.
CE & FCC Certified: Product holds CE and FCC certifications ensuring safety and compliance for global markets.
Adjustable Settings: Features 4 power levels and adjustable time range from 10 to 60 minutes for tailored therapy.
1-Year Warranty: Provides a 1-year warranty coverage for peace of mind and reliable after-sales support.
Portable Design: Compact watch-style design with 1600mAh battery, suitable for home, work, or travel use.

Company profile

Shenzhen Guangyang Zhongkang Technology Co., Ltd.
Importers and ExportersHigh Repeat Buyers ChoiceR&D CapabilitiesProduct Certification
CertifiedBusiness Type: Manufacturer/Factory & Trading Company CertifiedR&D Capacity: ODM Service Available & OEM Service AvailableAverage Response Time: ≤9.06h

AI-Powered supplier vetting

SummaryThe supplier demonstrates broad customization and R&D capabilities, including full customization, ODM services, recent product development, and three R&D engineers. Quality and service processes are documented, with ISO9001:2015, CE, and FCC certifications. It has 11 years of export experience, self-operated import/export rights, and exports representing 90% of total sales. Production-related evidence is limited, although the supplier reports OEM service for well-known brands and maintains quality inspection procedures. After-sales support is supported by technical assistance and documented complaint, corrective-action, and preventive-action procedures, but overseas service infrastructure is absent. Financial credibility cannot be assessed because the provided records identify years rather than financial results. Customer evidence includes OEM service for well-known brands and a 50%–80% repeat-buyer preference, but no Fortune 500 cooperation.
CertificationsThe supplier holds an ISO9001:2015 management-system certificate and reports CE and FCC product compliance certifications. These certifications provide explicit evidence of quality-system and product-compliance credentials.
After-Sales capabilityR&D engineers are responsible for technical support during production and after-sales service. The supplier also has documented and followed procedures for customer complaints and corrective and preventive actions, although no overseas warehouse, showroom, agent, or branch is available.
R&D capabilityThe supplier reports new products during the past year, ODM service, three R&D engineers, and responsibilities covering customer requirements, technical support, and new product development. However, it has no available SDK, so its innovation capability is supported for product development but not SDK-based integration.
Production capacityThe supplier reports OEM service for well-known brands, standardized finished-product inspection instructions, written warehouse quality-control procedures with records, two quality-control staff, and one test-equipment unit. These indicate operational and quality-control capability, though detailed production capacity and equipment information is not provided.
Customization capabilityThe supplier explicitly offers customization from samples and designs, full, minor, and flexible customization, together with ODM services. This is strong direct evidence of broad customization capability.
Client casesThe supplier reports OEM service for well-known brands, participation in the CMEF trade show, and a 50%–80% repeat-buyer preference. It reports no Fortune 500 cooperation, so the available customer evidence is positive but does not establish Fortune 500 experience.

Product Q&A

Q:How do I choose the power and treatment time?
A:
For the power, It is divided into four levels. For the time, It divided into 10 min, 20 min, 30 min, 40 min, 50 min, 60 min. For general patient, we suggested for 30 min with the highest power. It's suggested Twice or three times a day and 30 min per each treatment. The time and power can be according to your own fitness scale or adaptedness gradually add per each treatment time to 10 min or 60 min. After every 10 days treatment, pause 1 or 2 days. Then continues the next 10 days treatment.
Q:How to operate the semiconductor laser therapeutic instrument?
A:
Firstly, wear only for left hand. The device's back part correspond with the radial artery. If there is a lot of dirt on your nasal cavity laser probe or ear cavity laser probe before application, please clean it. When using nasal cavity laser probe, stick the nasal cavity head into your nose for 2-3 cm and clamp the nasal septum. Using way of ear cavity laser probe is the same as wearing common earphone. Press on/off key to turn on the device. You will see the LCD screen is on, only mode A is a
Q:How to find the Radial Artery?
A:
Using two fingers of your right hand to position the outside of the left hand's first wrist line (See the picture). Then, use the instrument backpart of the Radial Artery laser acupoint correspond with the hand's Radial Artery to wear the instrument on your left hand.
Q:May I choose do not use the nasal cavity irradiation?
A:
We strongly recommend that should combine with the nasal cavity irradiation. Thus, can get the maximum treatment efficiency. Before using the nasal cavity probe, DO USE the small cap to protect on the head. Please clean your nasal cavity head with 0.9% normal saline (sold in drugstores), or gently wipe by tissue. Then, stick the nasal cavity probe into your nose for 2-3 cm and clamp the nasal septum.
Q:What others should I pay attention to during the treatment period?
A:
You do not need to change your other living habits, while you should develop a certain diet or do certain exercise if you have cardiovascular and cerebrovascular diseases, hypertension, diabetes, etc. in addition, please do not use ethanol to clean your nasal cavities and the phototherapy instrument head, since ethanol irritates mucosa and will damage the probe shell. It is suggested to clean with 0.9% normal saline (sold in drugstores) or gently wipe with a wet pa per towel.

Send Inquiry

*To:Shenzhen Guangyang Zhongkang Technology Co., Ltd.Shenzhen Guangyang Zhongkang Technology Co., Ltd.
*Content:
0/4000

Supplier replies will be sent to your registered email

You may also like