SourcingAI
Try for free
Powered by Made-in-China.com
Fln36-12 12kv 3-Phase Sf6 Load Break Switch for Rmu Switchgear Panel
US$480.00-880.00
1 Piece
Sample price:US$900.00/piece.Request sample

Product profile

Customization

Available

Function

Industry

Structure

Epoxy Resin Cast Chamber

Model NO.

FLN36-12

Usage

Disconnector, Load Break Switch / Rmu Main Switch

Contact Type

Rotary Contact System

Detection Method

Type Test / Pressure Test

Pole

3

Rated Continuous Current

630A

Number of Switch

as Specification

Brand

Liyond

Certification

ISO9001

Product Name

Sf6 Load Break Switch

Voltage Level

Medium Voltage

Work Position

Closed, Open, Earth

Phase Distance

200mm (Customizable)

Rated Voltage

12kv

Rated Current

630A

Rated Short Circuit Breaking Current

20ka / 3s

Mechanism Type

K-Type (Single Spring) / a-Type (Double Spring)

Standard

IEC 62271-103 / GB/T 3804

Application Switchgear

Xgn15-12 / Rmu Cabinet

Arc Extinguishing Medium

Sf6 Gas

Control Motor Voltage

AC/DC 110V/220V, DC 24V (Optional)

OEM / ODM

Accept

Transport Package

Standard Export Packaging

Specification

12kV 630A

Trademark

Liyond

Origin

China

Key features

Three-Position Switch Integration: Combines Closed (ON), Open (OFF), and Earthed (EARTH) states in one SF6 gas chamber, eliminating mis-operation and ensuring earthing safety.
Leak-Free Epoxy Resin Housing: Sealed inside a high-strength epoxy resin cast shell with IP67 enclosure rating, preventing gas leakage and insulation breakdown in high-humidity areas.
12kV 630A Rated Performance: Delivers 630A rated current and 20kA/3s short-time withstand current, fully compliant with IEC 62271-103 and GB/T 3804 standards.
210mm Phase Distance Adaptation: Standard 210mm phase-to-phase distance design allows direct mounting inside XGN15-12 RMU cabinets and compact substations.
Dual Spring Mechanism Options: Supports K-type single spring for line control and A-type double spring (with fuse striker trip system) for transformer overload protection.

Company profile

CertifiedBusiness Type: Trading CompanyExport Year: 2011-04-07 CertifiedNearest Port: Ningbo Port, Shanghai PortAverage Response Time: ≤1.57h CertifiedTerms of Payment: LC, T/T, D/P, etc. CertifiedInternational Commercial Terms(Incoterms): FOB, CIF, CFR

About Our Factory & Business Background

AddressRoom 1801, building 2, 3 and 4, headquarters economic Park, No. 6688, Xuyang Road, Chengdong street, Yueqing City, Zhejiang Province
Plant Area1100 square meters
Number of Employees18
Registered Capital5,000,000 RMB
Average Lead TimePeak Season Lead Time: within 15 workdays Off Season Lead Time: within 15 workdays

Our Production Capability & Technical Expertise

Main ProductsMedium and High Voltage Switchgear, Switchgear Accessories, Vacuum Vircuit Breaker, Vacuum Circuit Breaker Accessories, Earthing Switch, Load Break Switch, Auxiliary Switch, Conductive Parts, Insulation Parts
R&D Engineers2 people

Our Industry Experience & Global Business Record

Year of Establishment2011-04-07
Main MarketsNorth America, South America, Europe, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea)
Number of Foreign Trading Staff7
Overseas Agent/BranchNo

Our Certifications, Standards & Industry Recognition

Product CertificationCE

Product Q&A

Q:What is the standard phase distance for this FLN36-12 model?
A:
The standard phase-to-phase distance for FLN36-12 is 210mm, matching standard XGN15-12 switchgear cabinet structures. Customized phase spacing can also be evaluated per design specifications.
Q:What is the difference between FLN36-12 and FLN36-24 models?
A:
FLN36-12 is rated for 12kV systems with a standard 210mm phase distance, whereas FLN36-24 is designed for 24kV systems with a standard 230mm phase distance and higher insulation withstand voltage levels.
Q:Can this SF6 load break switch be motorized for remote automation?
A:
Yes. Both K-type single spring and A-type double spring mechanisms support installation of AC/DC 110V/220V or DC 24V electric operating motors for SCADA integration.
Q:How does the A-type mechanism trip when a fuse blows?
A:
When a current-limiting MV fuse blows, its integrated pin striker activates the mechanical linkage of the A-type double-spring mechanism, instantly opening all three phases of the LBS to protect the transformer.
Q:What parameters should be submitted to confirm a custom quotation?
A:
Please confirm: Rated voltage (12kV), rated current (630A), mechanism type (K-type single spring or A-type double spring), control voltage (if motorized), phase distance, and auxiliary switch requirement.

Send Inquiry

*To:Yueqing Liyond Electric Co., Ltd.
*Content:
0/4000

Supplier replies will be sent to your registered email

You may also like

Liyond Rmu Outgoing Three-Station Load Switch
Made-in-China.com
Fln36-24 Indoor 24kv Manual Sf6 Load Break Switch
Made-in-China.com