UL21576 24AWG 4 Core TPU/Tpo Cable for Addressable Fire Alarm Detector
US$0.62-0.82
3,000 Meters

Product specifications

Number of Cores

Wire Gage(AWG)

Shielding Type

Sample price:US$55.00/meter.Request sample

Product profile

Customization

Available

Applicable Standards

UL21576

Typical Applications

Addressable Smoke and Heat Detector Loop Wiring

Model NO.

UL21576

Conductor Material

Bare Copper / Tinned Copper Stranded

Wire Gauge (AWG)

24AWG

Insulation Material

Tpo

Number of Cores

4 Cores

Shielding

Unshielded

Jacket Material

TPU

Rated Voltage

300V

Temperature Range

80℃

Outer Diameter

4.6mm

Flame Retardant Rating

VW-1/FT1/FT2

Environmental

RoHS/Reach

Packaging

305m

Transport Package

Coil Packed or Reel Packed

Specification

UL21576 24AWG×4C

Trademark

Longzhiyi

Origin

Guangdong, China

Key features

UL 21576 certified, meets strict electrical safety standards for addressable fire alarm and life safety systems
4-core optimized design for intelligent addressable detector loops, supporting power, data communication and isolation
Slim 4.6mm diameter fits easily in wall conduit, ceiling spaces and fire alarm junction boxes
VW-1/FT1/FT2 flame retardant rating, low-smoke zero-halogen formulation for life safety in fire events
Durable TPU/TPO jacket withstands building construction and long-term permanent installation
High-purity copper ensures reliable loop communication for addressable detector networks
RoHS & REACH compliant, environmentally safe for commercial and residential buildings
305m standard spool, convenient for fire system installers and electrical contractors

Company profile

Dongguan Longzhiyi Industrial Co., Ltd.
High Repeat Buyers ChoiceSelf-brandedPatents AwardedExhibition Experience
CertifiedBusiness Type: Manufacturer/Factory & Trading Company CertifiedR&D Capacity: ODM Service Available CertifiedCustomization Options: Customization from Samples, Customization from Designs, etc. CertifiedExport Year: 6 Years CertifiedNearest Port: Shenzhen PortAverage Response Time: ≤3.76h

About Our Factory & Business Background

AddressBuilding 2, No. 46 Qiheng Road, Qishi Town, Dongguan, Guangdong, China
Plant Area24630.3 square meters
Number of Employees72
Registered Capital1,300,000 RMB
Terms of PaymentLC, T/T, D/P, PayPal, Western Union, Small-amount payment
International Commercial Terms(Incoterms)FOB, CIF, CFR, EXW
Average Lead TimePeak Season Lead Time: within 15 workdays Off Season Lead Time: within 15 workdays
Minimum Order Quantity3000m
Supply Chain Partners10

Our Production Capability & Technical Expertise

Main ProductsElectric Wire, Industrial Cable, Cable Assembly, Control Cable, Power Cable, M12 Connector Wiring Harness
Production Lines8
Production MachinesIntermediate Drawing Machine, Falt Drawing Machine, 64 head fire extinguisher, Copper twisting machine, Computer extrusion machine, Vertical Injection Molding Machine
QA/QC inspectors4 people
Inspection Type for Finished Products100% inspection(Visual inspection)
Inspection Method for Finished ProductsHave instructions and uniformly followed
R&D Engineers3 people
Traceability of Raw MaterialsNo
Own BrandYes

Our Industry Experience & Global Business Record

Year of Establishment2008-07-17
Main MarketsDomestic
Repeat Buyers Choice80%~100%
Number of Foreign Trading Staff3
Overseas Agent/BranchNo
New Products Launched in Last yearYes

Our Certifications, Standards & Industry Recognition

Management System CertificationISO9001:2015
Product CertificationCCC, UL
Cooperated with Fortune 500No

Product Q&A

Q:Is this 4-core cable suitable for addressable fire alarm detector loops?
A:
Yes, the 4-core configuration is designed for addressable fire alarm systems, supporting loop power, bi-directional data communication and circuit isolation for intelligent detectors.
Q:Does this cable meet building fire codes for life safety systems?
A:
Yes, the UL 21576 certification and VW-1/FT1/FT2 flame retardant rating meet standard commercial and residential building fire codes for life safety systems.
Q:What is the maximum loop length for addressable fire alarm systems?
A:
For typical addressable fire alarm loops at 12-24V DC, this 24AWG cable supports loop lengths up to 1000 meters depending on device count and current draw.
Q:Is this cable suitable for installation in ceiling plenums?
A:
This standard version is suitable for conduit installation in plenum spaces. For direct plenum exposure without conduit, we recommend our specialized plenum-rated fire alarm cable variants.
Q:Do you offer this cable in red jacket standard for fire alarm systems?
A:
Yes, red jacket is the industry standard for fire alarm cables. Custom colors are also available for specialized system requirements.

Send Inquiry

*To:Dongguan Longzhiyi Industrial Co., Ltd.Dongguan Longzhiyi Industrial Co., Ltd.
*Content:
0/4000

Supplier replies will be sent to your registered email

You may also like

Premium 3 Core Bare Copper Fire Alarm Cable for Safety
Made-in-China.com
China 4 Core Submersible Rubber Cable for Pumps
Made-in-China.com