SourcingAI
Try for free
Powered by Made-in-China.com
Midea Shieldbox 85kw Vrf Vrv Central HVAC Air Condition Split Air Conditioners Air Conditioning System for Hotel
US$32,000.00-40,000.00
1 Piece
Sample price:US$40000.00/piece.Request sample

Product profile

Customization

Available

After-sales Service

Online Technical Support/Free Spare Parts/Onsite I

Warranty

1 Years

Model NO.

V8-0401

Type

Commercial Air Conditioner

Air Tube Material

Galvanized Sheet

Corrosion Durability

Higher

Operating Voltage

380/400 VAC

Noise Level

Low

Application Fields

Metallurgy

Mounting

Split

Lifetime

>20 years

Certification

RoHS, ISO, CE, CCC

Condition

New

Product Name

Midea V8 Commercial Vrv Vrf Air Conditioner

Refrigerant

R410A

Power Supply

380-415V/3pH/50Hz

Cooling Capacity

25.2kw-303kw

Heating Capacity

27kw-330kw

Power Input

5.3-106.2kw

Eer

4.76-2.85kw/Kw

Airflow Rate

12600-87000m3/H

Sound Pressure Level

56-70dB(a)

Compressor Type

DC Inverter

Transport Package

Seaworthy Fumigated Wooden Crate

Specification

2000*2000*900

Trademark

Midea

Origin

China

HS Code

8415

Production Capacity

50000piece/Year

Key features

Advanced Self-Learning Technology: Monitors equipment parameters for timely maintenance and optimal operation throughout the lifecycle.
HyperLink Communication System: Supports any wiring pattern with anti-interference up to 2000m distance, simplifying installation.
IP55 ShieldBox Protection: Fully enclosed electric control box protects against corrosion, sand, humidity, and insects.
SuperSense Refrigerant Monitoring: Up to 19 sensors ensure stability; digital twin technology prevents shutdowns during sensor failure.
Comprehensive One-Stop Service: Includes VRF design, model selection, installation material calculation, and start-up guidance.
High Corrosion Durability: Galvanized sheet air tube material ensures higher resistance to harsh environmental conditions.
Wide Cooling Capacity Range: Offers flexible cooling capacity from 25.2kw to 303kw for various commercial needs.

Company profile

CertifiedBusiness Type: Trading CompanyExport Year: 2004-01-01 CertifiedNearest Port: Guangzhou PortAverage Response Time: ≤11.72h CertifiedTerms of Payment: LC, T/T CertifiedInternational Commercial Terms(Incoterms): FOB, CIF, CFR, EXW

AI-Powered supplier vetting

SummaryBEIJING MIDEA OVERSEAS ENGINEERING & TECHNOLOGY CO., LTD. is presented as an HVAC engineering and equipment-supply provider offering design, commissioning, installation-related support, and a broad range of HVAC products. The available operational profile reports 50 quality-control staff, more than 10 production lines, output above the stated threshold, and one-month fulfillment in both off-peak and peak seasons. Export activity is substantial, with 90% of sales reportedly from exports, exporting since 2004, and coverage across South America, Africa, Southeast Asia/Mideast, Europe, and Australia. The supplier cites overseas projects and regional offices or engineering teams, but the slices do not provide certification records, audited financial evidence, or clear proof of product-development innovation. Customization capability is also not explicitly documented.
Supplier typeThe supplier is described as an HVAC engineering and equipment-supply company providing system design, equipment and accessory supply, commissioning, and installation-related services. Its stated portfolio includes VRF systems, chillers, heat pumps, fan coil units, rooftop units, AHUs, and BMS systems.
After-Sales capabilityThe company explicitly offers HVAC commissioning service and states that it has engineering installation teams in China and abroad, supported by regional and overseas offices. These facts indicate service capability beyond equipment supply, although warranty and spare-parts arrangements are not stated.
Production capacityThe supplier profile reports 50 quality-control staff, more than 10 production lines, and annual production output above the stated threshold. It also reports one-month order fulfillment in both off-peak and peak seasons, supporting a strong stated production and delivery capacity.
Client casesThe supplier reports overseas projects including Aji Railway, the African Union Conference Center, Abidjan Stadium, an Ethiopian National Oil headquarters building, Algerian villas and a satellite receiving station, and a Congo presidential residence. Export activity since 2004 and 90% export sales further support international project experience.

Product Q&A

Q:What is a split-type air conditioner and how does it differ from a window unit?
A:
A split-type air conditioner consists of two separate units: a quiet indoor unit mounted on a wall or ceiling inside the room, and a louder outdoor unit (compressor/condenser) installed outside. Unlike a window unit where all components are in a single box, this design allows for quieter operation indoors, more flexible installation, and generally higher efficiency and cooling capacity.
Q:What should I consider before buying and installing a split AC?
A:
Key considerations include: the room size/BTU (cooling capacity) required, energy efficiency rating (look for a high SEER or equivalent), the availability of a suitable outdoor wall or space for the external unit, proper electrical wiring, and professional installation. Correct sizing and installation are critical for performance and efficiency.
Q:How often should I clean or maintain my split air conditioner?
A:
For basic maintenance, clean the washable filters of the indoor unit every 2-4 weeks during peak season to maintain airflow and air quality. Schedule a professional maintenance service at least once a year. This typically includes a thorough cleaning of the indoor evaporator and outdoor condenser coils, checking refrigerant levels, and inspecting all components.
Q:Why is my split AC not cooling properly, or what do certain error codes mean?
A:
Common reasons for poor cooling include: clogged air filters, blocked indoor or outdoor coils, low refrigerant due to a leak, faulty thermistor (temperature sensor), or a dirty outdoor unit restricting airflow. Many modern units display error codes (e.g., E1, P1) for specific issues like sensor failure or communication errors between units. Always refer to your user manual for code definitions and troubleshooting, or contact a qualified technician.

Send Inquiry

*To:Beijing Midea Overseas Engineering & Technology Co., Ltd.Beijing Midea Overseas Engineering & Technology Co., Ltd.
*Content:
0/4000

Supplier replies will be sent to your registered email

You may also like

Roof Top Air Conditioner Central HVAC Air Condition System
Made-in-China.com
HVAC Systems for Fresh Air Condition/Return Air Condition
Made-in-China.com