SIEMENS 5SV3111-6 5SV compact residual current circuit breaker
US$85.29
1 Piece

Product profile

Customization

Available

Breaking Capacity

Low Voltage Circuit Breakers

Operation

Electric Type

Model NO.

5SV3111-6

Speed

Normal Type Circuit Breaker

Arc-extinguishing Medium

Air

Installation

Rail Type

Structure

MCB

Poles Number

3

Type

Circuit Breaker

Function

Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, OVP(Overvoltage Protection), RCCB

Certification

VDE, ISO9001-2000, CE, CB, CCC

Transport Package

Carton

Specification

one

Trademark

SIEMENS

Origin

Germany

HS Code

8536200000

Production Capacity

1000/Year

Key features

Compact 2-Pole Design: Optimizes space in electrical cabinets, ideal for installations with limited room.
High Sensitivity Protection: 30mA sensitivity provides effective protection against direct and indirect contact.
Robust Breaking Capacity: 6kA breaking capacity ensures safe interruption of fault currents and safeguards equipment.
Type AC Tripping: Suitable for detecting sinusoidal alternating residual currents common in industrial loads.
DIN Rail Mountable: Facilitates easy and quick installation in standard electrical enclosures.
Durable Construction: Engineered with high-quality thermoplastic for longevity in industrial environments.
Enhanced Safety: Significantly reduces the risk of electric shock and fire hazards caused by earth faults.
Siemens Brand Trust: Backed by global leader reputation, guaranteeing quality and innovation.

Company profile

Beijing Zhongping Technology Co., Ltd.
High Repeat Buyers ChoiceIn-stock CapacityLow MOQ100% Finished Products Inspection
CertifiedBusiness Type: Trading Company CertifiedR&D Capacity: ODM Service Available CertifiedCustomization Options: Customization from Samples, Customization from Designs, etc. CertifiedExport Year: 3 years CertifiedNearest Port: Tianjin PortAverage Response Time: ≤2.82h

AI-Powered supplier vetting

SummaryThe supplier is a professional technology provider with strong R&D capabilities, offering extensive customization and 3D software design services. However, it lacks new product innovation in the past year and does not offer overseas showrooms or participation in international trade shows. Financial data indicates stability, but there are no certifications for supplier management systems. The supplier has a limited number of quality control staff, potentially affecting production oversight. Despite these shortcomings, the company provides comprehensive after-sales services, ensuring factory production efficiency.
Supplier typeThe supplier is characterized as a professional technology supplier, serving industries such as cement, packaging, printing, and machine tools, and offering one-stop services including product sales and maintenance.
CertificationsThe supplier does not hold any certifications for supplier management systems.
After-Sales capabilityThe supplier provides comprehensive after-sales services, including installation, maintenance, and repair, to ensure efficient factory production.
Financial creditThe supplier's financial data from the last three years suggests stability, with consistent cash flow and financial capacity indicators.
R&D capabilityThe supplier has not introduced new products in the past year, indicating a lack of recent innovation.
Customization capabilityThe supplier excels in customization, offering full, minor, and flexible customization services, including 3D software design.

Product Q&A

Q:What is the primary function of the Siemens 5SV3111-6 residual current circuit breaker?
A:
The Siemens 5SV3111-6's primary function is to protect individuals from severe electric shock and to prevent fires that may arise from electrical faults. It achieves this by continuously monitoring the balance of current flowing into and out of a circuit; any imbalance, indicative of current leaking to ground, triggers a rapid disconnection of power. This proactive safety measure is crucial in industrial settings where electrical equipment is extensively used. This advanced level of protection i
Q:What types of electrical faults does the 5SV3111-6 effectively protect against?
A:
The Siemens 5SV3111-6 is specifically designed to protect against earth faults, which occur when electrical current deviates from its intended path and flows into the ground. This can happen due to damaged insulation, faulty wiring, or contact with conductive surfaces. The breaker's sensitivity of 30mA means it will trip when as little as 30 milliamperes of current is leaking to ground, a level considered dangerous to human life. Beyond direct protection from electric shock by ground faults, it
Q:Can the Siemens 5SV3111-6 be used in residential applications, or is it strictly for industrial use?
A:
While the Siemens 5SV3111-6 is engineered for the demanding requirements of industrial environments, its protective capabilities also make it suitable for certain high-risk residential applications where enhanced safety is desired or mandated. Many modern building codes and electrical standards recommend or require the use of residual current devices (RCDs) or residual current circuit breakers (RCCBs) in areas prone to moisture or where electrical safety is a significant concern, such as kitchen
Q:What is the significance of the '2-pole' designation for this circuit breaker?
A:
The '2-pole' designation for the Siemens 5SV3111-6 signifies that the circuit breaker is designed to interrupt both the live (phase) conductor and the neutral conductor simultaneously. This is a critical feature for effective residual current protection, as it ensures that the entire circuit is de-energized when a fault is detected, regardless of where the leakage current occurs. In a 2-pole RCCB, both the live and neutral conductors pass through the sensing coil of the residual current monitori
Q:How does the tripping characteristic 'Type AC' influence the application of this RCCB?
A:
The 'Type AC' tripping characteristic of the Siemens 5SV3111-6 means that it is primarily designed to detect and respond to sinusoidal alternating residual currents. These are the most common types of residual currents encountered in standard AC power systems, typically generated by faults in appliances and wiring that operate on alternating current. This characteristic makes the 5SV3111-6 highly suitable for a broad range of general-purpose industrial and commercial applications. While Type AC