SourcingAI
Try for free
Powered by Made-in-China.com
Single-Phase VFD Drive-Variable Frequency Drive for Water Pump Pressure Control with Dry-Run Protection
US$1.00-9,999.00
1 Piece

Product profile

Customization

Available

Application

Three Phase Transducer, General Transducer

Output Type

Single

Model NO.

zhongping79vfd9

Principle of Work

V/F Control Transducer

Switch Mode

PWM Control

Main Circuit Type

Voltage

Voltage of Power Supply

Low Voltage Variable-Frequency Drive

Link of Transformation

AC-DC-AC Variable-Frequency Drive

Nature of DC Power

Current Variable-Frequency Drive

Function

Energy Conservation and Efficiency Enhancement

Brand

Other

Transport Package

Carton

Specification

4.1KG

Trademark

Schneider

Origin

China

HS Code

8504409999

Production Capacity

1000PCS/Year

Key features

Dry-Run Protection: Integrated sensors detect low water levels and automatically stop the pump to prevent damage.
Energy Efficiency: Reduces energy consumption by 30-50% in centrifugal pump applications by matching motor speed to demand.
Advanced PID Control: Enables precise, real-time pressure regulation with closed-loop feedback for constant pressure systems.
Soft-Start and Stop: Gradually ramps motor speed to reduce mechanical stress, shock, and wear on pump components.
High Power Factor: Inherently high power factor of 0.95-0.98 eliminates the need for external power factor correction.
NEMA 3R Enclosure: Rugged, weather-resistant enclosure suitable for damp or dusty industrial and outdoor environments.
Single-Phase to Three-Phase: Converts single-phase input power to drive three-phase motors for versatile application compatibility.
Comprehensive Motor Protection: Includes overload, over/undervoltage, short-circuit protection, and thermal monitoring.

Company profile

Beijing Zhongping Technology Co., Ltd.
High Repeat Buyers ChoiceIn-stock CapacityLow MOQ100% Finished Products Inspection
CertifiedBusiness Type: Trading Company CertifiedR&D Capacity: ODM Service Available CertifiedCustomization Options: Customization from Samples, Customization from Designs, etc. CertifiedExport Year: 3 years CertifiedNearest Port: Tianjin PortAverage Response Time: ≤2.55h

AI-Powered supplier vetting

SummaryThe supplier is identified as a professional technical supplier providing 3D software design, ODM, industrial automation, product sales, installation, commissioning, maintenance, and repair services. It supports extensive customization and has documented finished-product inspection instructions, quality assurance, and stated lead times within 15 working days in both peak and off-peak seasons. However, it has no overseas showrooms, agents, branches, or offline trade-show experience, and no new products were developed in the past year. Supplier-management, corrective-action, and complaint-handling procedures exist but lack written records. Certification is listed as NIL, quality-control staffing is below five, and R&D engineer experience totals two years. Export activity is established, with 31%–40% of sales from exports and three years of export experience. Evidence of specific customer cases is not provided.
Supplier typeThe supplier explicitly identifies itself as a professional technical supplier and provides industrial automation-related one-stop services, including product sales, solutions, installation and commissioning, maintenance, and repair. Its stated focus covers cement, packaging, printing, rubber, textile, and machine-tool industries.
CertificationsSupplier management system certification is explicitly recorded as NIL. The provided information therefore does not demonstrate possession of relevant certifications.
After-Sales capabilityThe supplier states that it provides installation, commissioning, maintenance, and repair services and has a quality-assurance system. However, it has no overseas showroom, agent, or branch, and its complaint-handling procedure has no written records, limiting evidence of formalized after-sales execution.
Production capacityThe supplier reports lead times within 15 working days during both peak and off-peak periods, maintains written and uniformly followed finished-product inspection instructions, and lists annual production output above the stated threshold. Nevertheless, quality-control staffing is below five and the service-capability assessment procedure has no records.
Customization capabilityThe supplier explicitly offers customization from samples, customization from designs, full customization, minor customization, and flexible customization. The same capability is confirmed in two slices, providing direct evidence of broad customization coverage.

Product Q&A

Q:What is the typical warranty period for this type of VFD?
A:
Standard warranties typically range from 18 to 36 months from the date of shipment or installation. Some manufacturers offer extended warranties or longer periods, up to 60 months, especially when commissioned by a certified partner. Always verify the specific warranty terms and start date (manufacture, shipment, or installation).
Q:How does dry-run protection work on this VFD?
A:
Dry-run protection typically uses feedback from sensors (like pressure transducers or flow monitors) to detect the absence of water. When detected, the VFD rapidly shuts down the pump to prevent damage from running dry.
Q:Can this VFD control a three-phase motor using a single-phase power supply?
A:
Yes, many single-phase input VFDs are designed to convert single-phase power to a three-phase output, enabling the use of three-phase motors. Note that the input current will be higher than for a three-phase input, requiring a VFD sized accordingly.
Q:What is the expected energy savings when using this VFD for a water pump?
A:
Energy savings typically range from 30% to 50% for centrifugal pumps, especially when the pump operates at reduced speeds for extended periods. This is due to the cubic relationship between speed and power in centrifugal loads.
Q:How do I determine the correct VFD size (HP/kW) for my pump motor?
A:
The VFD should be sized based on the motor's full-load amps (FLA) and horsepower rating, often requiring a VFD with a higher HP rating than the motor to handle starting currents and potential overloads. Consult the VFD manufacturer's sizing guide for precise recommendations.

Send Inquiry

*To:Beijing Zhongping Technology Co., Ltd.Beijing Zhongping Technology Co., Ltd.
*Content:
0/4000

Supplier replies will be sent to your registered email

You may also like