Powered by Made-in-China.com
Advanced Direct Release Fire Trace Tube Fire Suppression System for Electrical Cabinets
US$130.00-3,000.00
1 Set
Product profile
Customization
AvailableFire Agent
Fk-5-1-12 / Hfc-227ea / CO2System Type
Direct ReleaseModel NO.
SNG21-06A, SNG21-06B, SNG21-06CActivation
Heat-Sensitive Detection TubeDischarge Method
Through Detection Tube OpeningTube Outer Diameter
6 mmTube Inner Diameter
4 mmNominal Actuation
170 +/- 10 C; Options 100/120/140 CTransport Package
Wooden CaseSpecification
FK/HFC: 1-9 kg; CO2: 2, 6, 10 kgTrademark
SYNERGYOrigin
ChinaHS Code
8424100090Production Capacity
3000 Sets/MonthKey features
Heat-sensitive detection tube provides automatic fire detection and system activation.
Direct release discharges extinguishing agent through the tube opening close to the fire source.
Compact arrangement supports assessed electrical cabinets and equipment enclosures.
Agent-specific models are available with FK-5-1-12, HFC-227ea or CO2.
Clean-agent charges range from 1 to 9 kg; CO2 charge options are 2, 6 and 10 kg.
Pressure signal devices and audiovisual alarms can be supplied to the agreed configuration.
Company profile
Business Type: Manufacturer/Factory CertifiedR&D Capacity: ODM Service AvailableExport Year: 2003-03-01 CertifiedNearest Port: Tianjin Port, Ningbo Port, Shanghai Port, Qingdao PortAverage Response Time: ≤10.67h CertifiedTerms of Payment: LC, T/T
AI-Powered supplier vetting
SummaryThe supplier is identified as a trading company rather than an offshore company or professional technical supplier. It offers broad customization and ODM services, but reports no 3D software design service, no new products in the past year, no SDK, and no OEM service for popular brands. After-sales support includes debugging, maintenance, repair, training, and equipment installation, with overseas service coverage listed in seven countries, although it has no overseas branches, agents, warehouse, or showroom. Service-control procedures and corrective-action records are documented, while the approved-supplier list lacks approval signatures or dates. ISO9001:2015 and CE-related certification capability are reported. Financial credibility cannot be confirmed because the provided financial indicators are all stated as zero. Production outsourcing procedures, contracts, and in-stock capability are either unknown or unavailable.
CertificationsThe supplier reports an ISO9001:2015 certificate and lists CE among its product certification capabilities. The slices do not provide certificate validity, scope, issuing body, or expiry details.
After-Sales capabilityAfter-sales offerings include debugging, maintenance, repair, training, and equipment installation, supported by listed overseas service countries and participation in Interschutz 2026. However, the supplier has no overseas agents or branches, warehouse, or showroom, so service delivery infrastructure is partly limited.
R&D capabilityThe supplier provides ODM services and multiple forms of customization, but reports no new products in the past year, no SDK, no 3D software design service, and no professional technical R&D capability. This indicates service-based design flexibility but limited demonstrated innovation infrastructure.
Customization capabilityThe supplier explicitly offers customization from samples, designs, full customization, minor customization, flexible customization, and ODM services. These statements directly support a broad customization offering despite the absence of 3D software design services.
Product Q&A
Q:How does a direct release fire detection tube system work?
A:
The heat-sensitive tube is routed near the potential fire source. When sufficient heat ruptures the tube, the system activates and extinguishing agent discharges through the tube opening.
Q:Can one system be filled with any of the three agents?
A:
No. Select the corresponding agent-specific model: SNG21-06A for FK-5-1-12, SNG21-06B for HFC-227ea, or SNG21-06C for CO2. Cylinders, valves and tubing must match the agent and pressure design; agents are not interchangeable in an installed unit.
Q:Is a separate discharge nozzle required?
A:
The direct release arrangement discharges through the detection tube opening. Select an indirect release model when a separate nozzle and discharge line are required.
Q:What agent charge sizes are available?
A:
FK-5-1-12 and HFC-227ea direct models offer 1, 2, 3, 4, 6 and 9 kg agent charges. CO2 direct models offer 2, 6 and 10 kg agent charges. These values are agent mass, not cylinder volume.
Q:What are the detection tube dimensions and activation temperature?
A:
The detection tube has a 6 mm outside diameter and 4 mm inside diameter. Nominal actuation is 170 +/- 10 degrees C. Tube options at 100 degrees C, 120 degrees C and 140 degrees C depend on the selected configuration and must be matched to the installation.
Send Inquiry
*To:
Beijing Synergy Technology Co., Ltd.
Beijing Synergy Technology Co., Ltd.*Content:
Supplier replies will be sent to your registered email
You may also like
Indirect Release Fire Trace Tube Fire Suppression System with Nozzles
US$130.00-3,000.00
1 Set(MOQ)
Automatic Fire Suppression Systems for Electrical Cabinet, Board
US$300.00-2,000.00
500 Pieces(MOQ)
DLP and Ilp Systems Automatic Fire Suppression Firetrace Systems Direct Release Clean Agent Systems
US$300.00-2,000.00
500 Pieces(MOQ)
Tube Type Automatic Fire Systems for Electrical Cabinet, Panels, Vehicles/Cars, Switchboard
US$29.00-299.00
200 Pieces(MOQ)
Electrical Fire Suppression Systems
US$500.00-2,000.00
500 Pieces(MOQ)
CO2 Direct Release Fire Trace Tube System for Equipment Enclosures
US$130.00-3,000.00
1 Set(MOQ)
Hfc-227ea Direct Release Fire Trace Tube System for Electrical Cabinets
US$130.00-3,000.00
1 Set(MOQ)
Fire Safe Hfc227ea Fire Suppression System for Electrical Cabinet
US$100.00-10,000.00
1 Piece(MOQ)
Hfc-227ea Indirect Release Fire Trace Tube System for Electrical Cabinets
US$130.00-3,000.00
1 Set(MOQ)
High Performance Hfc-227ea Gas Extinguishing Cabinet Fire Suppression System for Electrical Device
US$100.00-10,000.00
1 Piece(MOQ)
High Quality Dry Powder Fire Extinguishing System for Fire Suppression
US$1.00-20,000.00
1 Set(MOQ)
Hfc-227ea FM-200 Cabinet Fire Suppression System
US$100.00-10,000.00
1 Piece(MOQ)
Pressure Type Foam Proportioning System for Fire Suppression
US$100.00-10,000.00
1 Piece(MOQ)
Zxyx-0.25-J Pressure Relief Panel for Fire Suppression Systems
US$17.90-19.90
99 Pieces(MOQ)
Od8*6mm 170° Red PVC Fire Detection Tube Fire Trace System
US$5.10
5,000 Pieces(MOQ)
Fire Control Dry Powder System for Electrical Room
Negotiable
1 Set(MOQ)
High-Strength Pressure Relief Panel for Fire Suppression Systems
US$17.90-19.90
99 Pieces(MOQ)
Marine Fixed CO2 Automatic Fire Extinguisher System for Ship
US$1,000.00
1 Piece(MOQ)