SourcingAI
Try for free
Powered by Made-in-China.com
High-Precision Multis Transformer Oil Bdv Tester for Electrical Safety Provide Transformer Testing Equipment
US$1,650.00
1 Piece

Product specifications

100kV

Product profile

Customization

Available

After-sales Service

Provided

Warranty

One-Year

Model NO.

NRYH408E

Accuracy Grade

1

Load Way

Electronic Load

Display

Digital

Control

Computer Control

Weight

0-100Kg

Power Source

AC220V

Power Supply Voltage

AC 220V±22V

Power Frequency

50Hz±2.5Hz

Power

200W

Output Voltage

0kv-80kv

Boosting Speed

0.5~5.0kv/S (Step Interval 0.5, Total 10 Speeds

Total Voltage Distortion Rate

Less 3%

Ambient Temperature

0℃-+40℃

Relative Humidity

≤80%

Transport Package

Wooden Box with Foam Inside

Specification

standard

Trademark

Refine On

Origin

China

HS Code

9030899090

Production Capacity

100 Set Per Week

Key features

High-Precision Testing: Accuracy Grade 1 with 0-100kV output voltage and <2% total voltage distortion rate.
Automated Operation: Microcomputer control for automatic discharge, pressurization, stirring, and data printing.
Touch Screen Display: 800x480 large-screen color LCD with backlight for clear visibility in any lighting.
10 Boosting Speeds: 10 selectable speeds ranging from 0.5 to 5.0 kV/s with 0.5 kV step intervals.
Built-in Standards: Includes 13 test standards and 6 test methods with support for self-defined parameters.
Strong Anti-Interference: Designed to operate normally in strong electromagnetic field environments.
Comprehensive Protection: Equipped with over-voltage, over-current, and limit protective devices for safety.
One-Year Warranty: Includes one-year warranty coverage and provided after-sales service support.

Company profile

Refine On (Hebei) Electric Power Technology Co., Ltd.
R&D Capabilities100% Finished Products InspectionODM ServicesProduction Process Visualization
CertifiedBusiness Type: Manufacturer/Factory & Trading Company CertifiedR&D Capacity: ODM Service Available & OEM Service Available CertifiedCustomization Options: Customization from Samples, Customization from Designs, etc. CertifiedExport Year: 1 year CertifiedNearest Port: Tianjin PortAverage Response Time: ≤0.30h

AI-Powered supplier vetting

SummaryRefine On (Hebei) Electric Power Technology Co., Ltd is a technology-driven enterprise located in Baoding City, China. The company integrates R&D, production, sales, and after-sales service, offering a complete range of electric and testing equipment. It demonstrates strong R&D and customization capabilities but lacks overseas infrastructure and financial strength. Despite its ability to provide ODM and OEM services, its financial records show no profitability, with zero operating revenue and gross margin in recent years. The company has a robust quality assurance process but limited documentation on managing customer complaints.
Supplier typeRefine On is a technology-driven enterprise with integrated R&D, production, sales, and after-sales service, strategically located in a high-tech development zone.
After-Sales capabilityThe supplier offers a comprehensive after-sales service system including debugging, maintenance, repair, equipment installation, and training.
Financial creditThe supplier shows poor financial credibility with no operating revenue, gross margin, or current ratio recorded in recent years.
R&D capabilityThe supplier has introduced new products in the past year and offers ODM services but lacks SDK availability.
Production capacityThe supplier has a diverse production capability, manufacturing a variety of electrical and testing equipment.
Customization capabilityThe supplier provides extensive customization services, ranging from minor to full customization based on samples or designs.

Product Q&A

Q:What is the main function of the Insulating Oil Dielectric Strength Tester?
A:
Tests insulating oil's dielectric strength to detect impurities, moisture, or aging, ensuring safe operation of transformers and circuit breakers.
Q:How often should the Insulating Oil Dielectric Strength Tester be calibrated?
A:
At least once a year; shorten intervals for frequent use, harsh environments, or post-maintenance.
Q:What is the difference between the Closed Cup Flash Point Automatic Tester and the Open Cup Flash Point Automatic Tester?
A:
Closed Cup tests in sealed containers for low-flash oils; Open Cup tests in open containers for high-flash oils like insulating oil.
Q:What can the Transformer Capacity Tester detect?
A:
Detects transformer's actual capacity, no-load/load loss, no-load current, and impedance voltage; judges compliance and faults.
Q:How to use the Transformer Tap Changer Tester?
A:
Connect test lines to tap changer terminals per manual. Power on, select test mode. View results; disconnect and power off after. De-energize and ground transformer first.