Sinnowa Ds-261 Fully Automatic Biochemistry Analyzer with CE, ISO Certificate, 260 Tests/Hr
US$4,000.00
1-2 unit
US$3,800.00
3-4 unit
US$3,600.00
5+ unit

Product profile

Customization

Available

Classification

Biochemical Apparatus

Type

Biochemistry Analyzer

Model NO.

DS-261

Certification

CE, ISO13485

Transport Package

Wooden Case or Carton

Specification

849*714* 540mm

Trademark

SINNOWA

Origin

Nanjing

HS Code

9027809990

Production Capacity

1000 Units/Year

Key features

High Throughput Performance: Achieves 260 tests per hour with random access capability for efficient workflow.
Advanced Reagent Management: 47 reagent positions with automatic liquid level detection and volume tracking.
Comprehensive Cleaning System: 8-channel automatic washing with up to 16 cleaning cycles to prevent cross-contamination.
Flexible Sample Handling: 50 expandable sample positions supporting original tubes, serum cups, and barcodes.
AI-Enhanced Software: Intelligent control and calibration management to ensure reliable operation and ease of use.
Robust Error Correction: Automatic malfunction diagnosis and correction for collision, reagent, and sample issues.
Versatile Wavelength Range: Operates from 330nm to 850nm with 8 standard filters and optional additional filters.
Large Data Storage Capacity: Stores over 5000 items and 2 million results with multiple printing format options.

Company profile

CertifiedBusiness Type: Manufacturer/Factory & Trading Company CertifiedR&D Capacity: ODM Service Available & OEM Service AvailableExport Year: 2002-10-01 CertifiedNearest Port: Shanghai PortAverage Response Time: ≤15h CertifiedTerms of Payment: LC, T/T, D/P, etc.

AI-Powered supplier vetting

SummarySINNOWA Medical Science & Technology Co., Ltd. is a China-based medical manufacturing company established in 2002, with 215 employees and a 66,000 m² manufacturing plant. It produces in vitro diagnostic equipment and related reagents, including automatic electrolyte analyzer standard solutions. The supplier reports ISO 9001:2015 certification and compliance with ISO 13485 and ISO 9001, while CE certification is stated and FDA certification is in progress. Its R&D organization includes more than 70 specialists and engineers, and it operates five production lines with 11–20 quality-control staff. The supplier reports exports to multiple regions, products sold in more than 80 countries through distributors and OEM partners, and order lead times within 15 working days in both peak and off-peak periods. Evidence is insufficient to assess financial credibility and customization capability directly.
Supplier typeThe supplier is identified as SINNOWA Medical Science & Technology Co., Ltd., a Chinese limited company and factory based in Jiangsu. Its stated business is manufacturing in vitro diagnostic equipment and related reagents, including chemistry and electrolyte analyzers.
CertificationsThe supplier reports ISO 9001:2015 certification and states that its diagnostic products comply with ISO 13485 and ISO 9001. It also states that all products are CE certified, while FDA certification is still in progress, so certification coverage is positive but not complete for FDA requirements.
R&D capabilitySINNOWA reports an R&D team of more than 70 specialists and engineers, with 50% holding master’s degrees, and 20 years of R&D engineer experience. Its product range covers multiple in vitro diagnostic categories, supporting a positive assessment of technical development capacity.
Production capacityThe supplier reports 215 employees, five production lines, a 66,000 m² manufacturing plant, and 11–20 quality-control staff. It also states that peak- and off-peak-season order fulfillment is within 15 working days, indicating established manufacturing and delivery capacity.
Client casesThe supplier states that its products have been sold in more than 80 countries through distributors and OEM cooperators, and reports export activity beginning in 2002 with multiple international markets served. These statements provide direct evidence of broad international customer and channel experience.

Product Q&A

Q:What is the testing throughput of this analyzer?
A:
The analyzer has a throughput of 260 tests per hour.
Q:How many sample and reagent positions are available?
A:
It features 50 expandable sample positions and 47 reagent positions (26 for R1 and 21 for R2).
Q:Does the machine support automatic error correction?
A:
Yes, it is equipped with automatic test error diagnosis and correcting functions for issues like collisions or insufficient reagents.
Q:What certifications does the product hold?
A:
The product holds CE and ISO13485 certifications.
Q:Can the sample tray be expanded?
A:
Yes, the sample tray has 50 positions and is expandable.