Air Driven Nitrogen and Purified Helium Gas Booster System to Laboratory
US$3,000.00-4,600.00
1 set

Product profile

Customization

Available

After-sales Service

13 Monthes

Warranty

13 Monthes

Model NO.

DGS-DGD40He-DGD100N2-W1

Max.Head

10-30m

Max.Capacity

>400 L/min

Pressure Medium

Gas

Type

Desktop

Position of Pump Shaft

Horizontal

Certification

CE, ISO

Material

Stainless Steel

Power

Pneumatic

Application

Increasing Gas Pressure, Transferring and Filling

Boost Medium

Nitrogen/Helium

Certificate

CE/ATEX/ISO

Drive Air Pressure

3-8 Bar

Drive Air Consumption Flow Rate

1600 L/Min (Maximum)

Outlet Pressure (Nitrogen System)

≤ 800 Bar

Outlet Pressure (Helium System)

≤ 320 Bar

Filter Accuracy

5 μm

Transport Package

1 Set/Case by Plywood Case

Specification

800*560*680mm

Trademark

SUNCENTER

Origin

China

HS Code

8414809090

Production Capacity

100 Sets/Month

Key features

Dual Pump Independent Control: The two sets of pressurization systems share the same chassis, but the gas inlet, high-pressure outlet and operation are independent. Both pumps can be operated simultan
Wide Driving Air Source Adaptation: Only 3-8 bar of compressed air is required, with a flow rate of 1600 L/min. Ordinary factory air sources can drive it.
High Pressure Output: The nitrogen gas is pressurized to 800 bar, and the helium gas is pressurized to 320 bar, meeting the requirements of the high-pressure process.
Automatic Start/Stop: It will automatically shut down once the preset pressure is reached, and the operation is simple. In case of an emergency, can quickly stop by pressing the red drive air switch.
Sanitation Assurance: The low-pressure inlet is equipped with a 5-micron gas filter, which effectively removes impurities; On the nitrogen pump side, there is an oil mist lubricator (F.R.L).
Safe and Reliable: The entire machine has passed the CE certification and is equipped with an unloading valve for system pressure relief, ensuring the safety of operators.

Company profile

CertifiedBusiness Type: Manufacturer/Factory & Trading Company CertifiedR&D Capacity: ODM Service Available & OEM Service AvailableExport Year: 2013-05-01 CertifiedNearest Port: Guangzhou Port, Shenzhen PortAverage Response Time: >24h CertifiedTerms of Payment: LC, T/T, D/P, etc.

About Our Factory & Business Background

AddressNo. 285, Guantai Road, Yuanwubian, Nancheng District, Dongguan, Guangdong, China
Plant Area2000 square meters
Number of Employees40
Registered Capital1,000,000 RMB
International Commercial Terms(Incoterms)FOB, CIF, CFR, , EXW
Average Lead TimePeak Season Lead Time: one month Off Season Lead Time: within 15 workdays

Our Production Capability & Technical Expertise

Main ProductsHigh Pressure Pumps,Air/Hydro Pressure Testing Machines,Gas filling machines,Valve Testing Machines etc.
Production MachinesAssembly Line, Air Hydraulic Pump
R&D Engineers2 people
Own BrandYes

Our Industry Experience & Global Business Record

Year of Establishment2021-05-26
Main MarketsSouth America, Europe, Southeast Asia/ Mideast
Number of Foreign Trading Staff8
Overseas Agent/BranchNo

Product Q&A

Q:What external air source is required by the system?
A:
We require clean and dry compressed air with a pressure range of 3 to 8 bar, and the supply flow rate should be no less than 1600 liters per minute. Insufficient pressure will result in a slow pressurization speed, while excessive pressure may damage the driving components.
Q:Can the two pumps work simultaneously? Will they interfere with each other?
A:
They can work simultaneously. The gas paths of the two systems are independent and do not interfere with each other. Just ensure that the total driving air flow is sufficient.
Q:How can one determine if the lubrication is functioning properly?
A:
For the DGD100 nitrogen pump, before starting the operation, please check that the oil level in the F.R.L oil cup is at least half full, and adjust the oil dripping speed to 3-5 drops per minute. If the oil cup is empty of oil, the pump will wear out excessively.
Q:Why does the equipment automatically stop once it reaches the set pressure? How to restart?
A:
When the outlet pressure reaches the preset value, the internal pressure switch will cut off the driving air and the pump will automatically stop. To restart, you need to first open the disconnection valve to release the pipeline pressure, and then pull up the driving air switch.
Q:Why is the maximum output pressure of the helium system lower than that of the nitrogen system?
A:
Helium molecules are small and prone to leakage. Moreover, the sealing technology is more demanding, so the designed safety limit is set at 320 bar. Do not attempt to use beyond the rated capacity to avoid danger.

Send Inquiry

*To:Dongguan Suncenter Fluid Pressure Technology Co., LtdDongguan Suncenter Fluid Pressure Technology Co., Ltd
*Content:
0/4000

Supplier replies will be sent to your registered email

You may also like