Model NO.

TD3500

Application

Electrical Calibration

Power

Electricity

Voltage Output

264V

Current Output

120A

LCD Display

With LCD Display

Customized

Non-Customized

Accuracy

Class 0.05 or 0.1

Frequency

45 Hz ~ 100 Hz

Minimum Current Output

1 mA

Multiple-position Test

6/12/16/24

Transport Package

Package for Exporting

Trademark

TUNKIA

Origin

China

Production Capacity

1000

Key features

High Precision Accuracy: Offers Class 0.05 or 0.1 accuracy for reliable electrical calibration.
Multi-Position Testing: Supports simultaneous verification of 6, 12, 16, or 24 energy meters.
Wide Frequency Range: Operates within 45 Hz to 100 Hz fundamental frequency range.
Low Current Output: Capable of minimum current output as low as 1 mA.
Harmonic Output Option: Optional loadable 2nd to 21st harmonic output with adjustable content.
Automatic Range Switching: Features auto range switching and load matching for efficiency.
Comprehensive Verification: Tests no-load starting current, intrinsic error, and daily reckoning error.
Professional Software: Supports semi-automatic or fully automatic verification with data management.

Company profile

Tunkia Co., Ltd.
Tunkia Co., Ltd.Hunan, China
CertifiedBusiness Type: Manufacturer/Factory CertifiedR&D Capacity: ODM Service Available & OEM Service AvailableExport Year: 2021-10-11 CertifiedNearest Port: Changsha PortAverage Response Time: ≤18h CertifiedTerms of Payment: LC, T/T, D/P, etc.

AI-Powered supplier vetting

SummaryTunkia Co., Ltd. is identified as a China-based manufacturer established in 2006, with 363 employees and an 8,000 m² manufacturing plant. Its stated products include magnetic and electrical measurement equipment, gaussmeters, and multifunction calibrators. The supplier reports ISO9001, ISO14001, and ISO45001 certifications, nine production lines, 120 years of combined R&D engineer experience, and 11–20 quality-control staff. It serves domestic and overseas markets, with exports representing 21%–30% of sales and reported one-month lead times in both off-peak and peak seasons. Evidence supports manufacturing scale, certification coverage, and technical capability. However, the provided information does not sufficiently establish after-sales service, financial credibility, customization capability, or a broad customer track record.
Supplier typeThe supplier is explicitly classified as a manufacturer, while the associated company information also describes the company nature as a trading company. Its 8,000 m² plant and manufacturing-related business activities support that it operates manufacturing capabilities, although the supplied classifications are not fully consistent.
CertificationsThe supplier reports ISO9001:2015, ISO14001:2015, and ISO45001:2016 management-system certificates, plus other unspecified certifications. This is explicit evidence of multiple quality, environmental, and occupational-health-and-safety certifications.
R&D capabilityThe supplier’s product scope includes magnetic measurement, electrical measurement, gaussmeters, and multifunction calibrators, and it reports 120 years of total R&D engineer experience. These details support technical and product-development capability, although no patent, new-product, or R&D investment data is provided.
Production capacityThe supplier reports an 8,000 m² manufacturing plant, 363 employees, nine production lines, and one-month lead times in both off-peak and peak seasons. These figures provide explicit evidence of established production capacity and stated delivery capability.

Product Q&A

Q:What is the accuracy class of the TD3500?
A:
The device offers accuracy classes of 0.05 or 0.1.
Q:How many energy meters can be tested simultaneously?
A:
It supports simultaneous verification of 6, 12, 16, or 24 single-phase meters.
Q:What is the frequency range supported?
A:
The fundamental frequency range is 45 Hz to 100 Hz.
Q:Is the product customizable?
A:
The standard product is non-customized, but optional features like harmonic output and standard meters are available.
Q:What is the minimum current output capability?
A:
The minimum current output can be as low as 1 mA.

Send Inquiry

*To:Tunkia Co., Ltd.Tunkia Co., Ltd.
*Content:
0/4000

Supplier replies will be sent to your registered email

You may also like

TD3550  Single-Phase Energy Meters test bench

TD3550 Single-Phase Energy Meters test bench

US$35,000.00-60,000.00
1 Set(MOQ)
Made-in-China.com
GF102 Portable Single Phase Energy Meter Test Bench
Made-in-China.com
TD3600 Three-Phase Energy Meters Test Bench

TD3600 Three-Phase Energy Meters Test Bench

US$29,000.00-62,000.00
1 Set(MOQ)
Made-in-China.com
TD3650 Three-phase Energy Meters calibration/Test bench
Made-in-China.com
H+W High Accuracy Dry Block Temperature Calibrator
Made-in-China.com