SourcingAI
Try for free
Powered by Made-in-China.com
Easy Upgrade Long Lifespan 100W RF Drone Counter Module for Cable Television
US$123.00
1 Piece

Product specifications

Type

Product profile

Usage

Telephone, Workstation, Mobile Phone

Support Network

GSM

Information Content

Data

Model NO.

Anti-Drone Power Amplifier

Certification

CE

Condition

New

Product Name

Uzi-Auds-100W-16555-En

Keywords

Power Amplifier

Maximum Input Level

+3dBm

Vswr

≤1.4

Vswr Alarm

Open Circuit Alarm: Alarm Voltage 2.7-3.3V

Operating Current

≤8.5A

Working Temperature

-40~+55℃

Over-Temperature Protection

Shutdown at +90℃, Resume at 65℃

Chassis Dimension

165*55*24.5

Transport Package

Standard Packaging or Customized

Specification

Standard Specifications or Customized

Trademark

UZIWAVE

Origin

Fujian, China

Production Capacity

50000pieces/Year

Key features

Multi-Band Coverage: Supports 8 frequency bands from 425MHz to 5900MHz for comprehensive drone defense.
Real-Time Monitoring: Includes forward/reverse power detection and VSWR alarm monitoring.
Compact Design: Chassis dimensions are 165*55*24.5mm for easy integration.
CE Certified: Product meets CE certification standards for safety and compliance.

Company profile

Business Type: Manufacturer/FactoryAverage Response Time: ≤0.52h

About Our Factory & Business Background

AddressXiamen, Fujian, China

Our Production Capability & Technical Expertise

Main ProductsPower Amplifier, Mesh Network, Anti-Drone Module, Repeater, Electronic Fence

Product Q&A

Q:What should I check if the output power of the power amplifier is lower than expected during testing?
A:
Troubleshoot step by step: a. Check input signal strength. b. Verify software settings for ALC function. c. Inspect rear-end components like cables and connectors for excessive loss. d. Test the amplifier independently to confirm hardware faults.
Q:What are the possible causes if the power amplifier gain fails to meet expectations, and how to solve them?
A:
Causes include software settings, system loss, and hardware failures. Solutions: a. Adjust software attenuation parameters. b. Calibrate the test system components. c. Test the amplifier independently to identify hardware faults.
Q:How to accurately locate the problem if the software or instrument shows a high VSWR of the power amplifier?
A:
Troubleshoot based on scenario: a. If software detects high VSWR, replace rear-end components one by one. b. If instrument detects high VSWR, calibrate the test system first. c. If issues persist, it may be a hardware fault requiring professional maintenance.
Q:What are the connector types used for input and output?
A:
The input uses an SMA connector, and the output uses an N-type connector.
Q:Does this module support ALC control?
A:
No, the power amplifier does not have an ALC (Automatic Level Control) function.