Powered by Made-in-China.com
Over-Temp Protected 5W V-MIMO-SMA Power Amplifier for Marco Base Station
US$123.00
1 Piece
Product specifications
Type
Product profile
Certification
CECondition
NewUsage
Telephone, Workstation, Mobile PhoneModel NO.
UZI-TDD-5.25-5.85G-5W-127110ZK-4JT-(16-36)V-MIMSupport Network
GSMInformation Content
DataProduct Name
Uzi-Tdd-5.25-5.85g-5W-127110zk-4jt-(16-36)V-MIMKeywords
V-MIMO-SMA Power AmplifierConnecters
4 SMA Connectors in TotalWorking Temperature
-40~+55℃in-Band Ripple
≤4db (Filter Added to Uplink)Operating Current
≤3.8AOperating Voltage
24VTransport Package
Standard Packaging or CustomizedSpecification
Standard Specifications or CustomizedTrademark
UZIWAVEOrigin
Fujian, ChinaProduction Capacity
50000pieces/YearKey features
Broad Operating Frequency: Covers 5250MHz-5850MHz with optimized uplink filtering for stable signal transmission.
Wide Voltage Input: Built-in power management supports 16-36V wide voltage input for flexible supply.
Compact Integration: Dimensions 127*110*16.5mm, weighing 388g with 4 SMA connectors.
Company profile
Business Type: Manufacturer/FactoryAverage Response Time: ≤0.98h
About Our Factory & Business Background
AddressXiamen, Fujian, China
Our Production Capability & Technical Expertise
Main ProductsPower Amplifier, Mesh Network, Anti-Drone Module, Repeater, Electronic Fence
Product Q&A
Q:What should I check if the output power of the power amplifier is lower than expected during testing?
A:
It is recommended to troubleshoot step by step as follows, prioritizing the elimination of non-hardware failure factors: a. Check the input signal: Verify whether the input signal to the power amplifier meets the standard requirements. A weak input signal is a common cause of low output power. b. Verify software settings: Check if the ALC (Automatic Level Control) function of the power amplifier has been set to a low output power level via software. Adjust it to appropriate parameters and retest
Q:What are the possible causes if the power amplifier gain fails to meet expectations, and how to solve them?
A:
The core troubleshooting directions for low gain of the power amplifier include software settings, system loss, and hardware failures. The specific solutions are as follows: a. Adjust software attenuation parameters: First, check the power amplifier control software to confirm whether the ATT (Attenuator) attenuation function is enabled. If so, reduce the attenuation or disable the function as needed. b. Calibrate the test system: Perform systematic calibration on the cables, connectors, passive
Q:How to accurately locate the problem if the software or instrument shows a high VSWR (Voltage Standing Wave Ratio) of the power amplifier?
A:
Abnormal VSWR is mostly related to link matching, and troubleshooting should be carried out step by step according to different test scenarios: a. Abnormal VSWR detected by software: In most cases, it is caused by excessive VSWR of components connected to the rear of the power amplifier, such as cables, connectors, and passive components. Replace the rear-end components one by one and retest to locate the faulty component. b. Abnormal VSWR detected by instrument: It is necessary to first calibra
Send Inquiry
*To:
Xiamen Yaozhi Huasheng Communication Technology Co., Ltd.
Xiamen Yaozhi Huasheng Communication Technology Co., Ltd.*Content:
Supplier replies will be sent to your registered email
You may also like
47dBm Acpr 45dbc Linear Tdd RF Power Amplifier for SDR & Micro Bts
US$950.00
1 Piece(MOQ)
VHF UHF Tetra Linear Dpd High Acpr Tdd FDD Power Amplifier for Base Station SDR
Negotiable
1 Piece(MOQ)
23dBm 850MHz 2100MHz 3G Booster Power Amplifier for Basement (GW-23CW)
US$149.80-171.20
1 Piece(MOQ)
53dBm WCDMA Ldmos High Efficiecny RF Power Amplifier for Laboratory Testing Instruments
US$1,000.00
1 Piece(MOQ)
50dBm 4G LTE 2600MHz RF Modular of Power Amplifier GSM WCDMA
US$530.00
1 Piece(MOQ)
Tetra 400-43dBm Low Frequency Line Amplifier for UHF VHF Inbuilding Solution
US$1,000.00-1,500.00
10 Pieces(MOQ)
37dBm PCS 1900MHz Ics Power Cellphone Booster 2g 3G 4G Signal Amplifier (GW-37-ICSP)
US$1,973.50-2,240.26
1 Piece(MOQ)
VHF 150-40 dBm Bda Solution Line Amplifier for 2 Way Radio System and Ibs
US$1,000.00-1,500.00
10 Pieces(MOQ)
300W S Band Pulse 3.1-3.5GHz GaN Pulse Solid State Satellite Power Amplifier
US$3,800.00
1 Piece(MOQ)
Uziwave-Tdd-5.25-5.85g-5W-V-MIMO-SMA Power Amplifier for Marco Base Station
US$123.00
1 Piece(MOQ)
40dBm Dcs1800 3G 4G Antenna Booster Power Amplifier (GW-40D)
US$1,500.00-1,725.00
1 Piece(MOQ)
Wide Temp 5W Tdd V-MIMO-SMA Power Amplifier for Marco Base Station
US$123.00
1 Piece(MOQ)
Tri Band Commercial Cellular Signal Amplifier for Tunnel Coverage with High Output Power
US$1,200.00-1,500.00
1 Piece(MOQ)
5W 1800MHz GSM Repeater Wireless Phone Booster Mobile Amplifier (GW-37D)
US$1,300.00-1,495.00
1 Piece(MOQ)
Over-Temp Protected 20W Tdd Power Amplifier for Marco Base Station
US$123.00
1 Piece(MOQ)



















