SourcingAI
Try for free
Powered by Made-in-China.com
Built-in Back-Flush Procedure Automatic Ignition Vocs Equipment for Total Hydrocarbons and Auxiliary Environmental Parameters
US$21,980.00
1-3 Pieces
US$21,300.00
4+ Pieces

Product profile

Customization

Available

After-sales Service

Perpetual

Application

Environmental Monitoring

Model NO.

LZG-VOCS-200

Target Analytes

Total Hydrocarbons (Thc), Methane (CH4), Non-Metha

Measuring Range

0-100 / 200 / 500 / 5000 Mg/M³ (Range Extendable)

Auxiliary Parameters

Temperature; Pressure; Flow Velocity; Humidity; Ox

Detection Limit

≤ 0.05 Ppm (for Nmhc)

Repeatability

Rsd ≤ 2%

Analysis Time

≤ 2 Min (for CH4 & Nmhc); Benzene Series ≤ 480 S;

Indication Error

≤ ±2% of F.S.

Zero Drift

≤ ±2% F.S. / 24 H

Span Drift

≤ ±2% F.S. / 24 H

Response Time

≤ 300 S (for Nmhc)

Accuracy

≤ ±10%

Calibration Cycle

Weekly

Output

RS232 / RS485

Environmental Conditions

Operating: 5-45 °C, <90% Rh (Non-Condensing); Stor

Gas Supply

Hydrogen (H2) and Zero-Grade Air

Transport Package

Slatted Crate

Specification

900mm × 700mm × 1710mm

Trademark

Yongan

Origin

Jiangsu, China

Production Capacity

10000+/Year

Key features

Full-Stream Trace Heating: Prevents cold spots and sample loss for accurate measurement of high boiling point VOCs.
Intelligent Column Protection: Auto backflush function extends column life and reduces maintenance frequency.
Safe Autonomous Operation: Auto hydrogen shutoff and power-recovery autorestart ensure safety and uptime.
Comprehensive Auxiliary Sensors: Monitors temperature, pressure, flow, humidity, and oxygen for full stack data.
Fully heat-traced line with zero cold spots prevents condensation and adsorption, delivering authentic data.
Automatic backflush after each cycle removes residual heavy components, extending column life and reducing maintenance costs.
Auto-ignition, hydrogen cut-off on flame-out, and auto-restart after power failure ensure safe unattended operation.

Company profile

Wuxi Yongan Electronic Technology Co., Ltd.
Importers and ExportersSelf-brandedFast DeliveryLow MOQ
Business Type: Manufacturer/FactoryExport Year: 2019-01-01Nearest Port: Shanghai, NingboAverage Response Time: ≤0.21hTerms of Payment: T/T, PayPal, Western UnionInternational Commercial Terms(Incoterms): FOB, EXW, CIF, CFR, CIP, DAP, DDP, CPT

About Our Factory & Business Background

AddressWuxi, Jiangsu, China
Average Lead TimePeak Season Lead Time: within 15 workdays Off Season Lead Time: within 15 workdays

Our Production Capability & Technical Expertise

Main ProductsCombustibl/Toxic Gas Leak Alarm Control System, Zirconia Oxygen Analyzer, Cems Flue Gas Online Monitoring System, Temperature Transmitter, Pressure Transmitter, Fixed Combustible/Toxic Gas Detector, Pipeline Spark Alarm and Control System, Flow Meter, Dust Detector, Temperature and Humidity Transmitter

Our Industry Experience & Global Business Record

Main MarketsAfrica, Southeast Asia, North America, South America, Mid East, Eastern Asia, Eastern Europe, Western Europe

Our Certifications, Standards & Industry Recognition

Management System CertificationISO9001:2015, ISO45001:2018, ISO14001
Product CertificationCE, Others

Product Q&A

Q:Which gases does this system primarily monitor?
A:
The core monitoring targets include total hydrocarbons, methane, non-methane hydrocarbons (NMHC), and benzene series (BTEX). For specific industrial scenarios, we can also customise the system for other VOC characteristic factors.
Q:How long does one analysis cycle take?
A:
The standard analysis cycle for methane and NMHC is no more than 2 minutes. For BTEX, the total analysis time is within 480 seconds. For other customised characteristic factors, the cycle can be adjusted according to customer requirements.
Q:How is sample concentration loss prevented during long-distance transport?
A:
We employ a fully heat-traced sampling and transport line, maintaining a constant elevated temperature throughout the entire flow path. This eliminates any "cold spots" that could cause condensation and adsorption of high-boiling components, thereby preserving the representativeness and authenticity of the monitoring data.
Q:Is the chromatographic column easily damaged by high concentrations of pollutants? Are maintenance costs high?
A:
The system incorporates an automatic backflush cleaning function that, after each analysis, reverses the flow to purge residual high-boiling substances from the column. This effectively protects column cleanliness, extends the service life of this critical component, and significantly reduces the cost of routine consumable replacement.
Q:What safety features are built into the equipment?
A:
Multiple safety redundancies are in place. The FID detector can automatically re-ignite, and if a flame-out is detected, the system immediately shuts off the hydrogen supply to prevent leakage. Moreover, the unit has power-loss memory and auto-recovery -after power is restored, it restarts automatically without manual intervention.

Send Inquiry

*To:Wuxi Yongan Electronic Technology Co., Ltd.Wuxi Yongan Electronic Technology Co., Ltd.
*Content:
0/4000

Supplier replies will be sent to your registered email

You may also like