WaterTemperature
Ordinary TemperatureModel NO.
HS41XMaterial
Cast IronConnection Form
FlangeStructure
Dual Check with Intermediate Relief AssemblyPressure
Ordinary PressureFunction
Backflow Prevention and Water Supply IsolationSealing Form
Soft SealingFlow Direction
UnidirectionStandard
GBApplication
Water Industrial UsageProduct Name
Reduced Pressure Zone Backflow PreventerModel
HS41XValve Type
Backflow PreventerNominal Diametre
DN50-300Nominal Pressure
Pn10-16Working Temperature
0℃ ~ 80℃Valve Body
Ductile IronInternal Component
Stainless SteelAdvantages-01
High Safety Backflow ProtectionAdvantages-02
Prevents Contamination & Water HammerCertification
GS, CE, ISO9001Transport Package
Seaworthy Wooden CaseSpecification
DN50-DN300Trademark
ZentifOrigin
ChinaHS Code
8421199090Production Capacity
50000Key features
Robust Backflow Protection: Reduced-pressure-zone design ensures safety against backpressure and back-siphonage.
Durable Ductile Iron Body: Provides strong mechanical strength and resistance to high pressure environments.
Corrosion Resistant Components: Stainless steel stems and springs ensure long-term reliability in water systems.
Self-Operated Operation: No electricity or external actuator required for automatic pressure relief.
Wide Size Range: Available in sizes from DN50 to DN300 for various pipeline applications.
Multiple Certifications: Certified by GS, CE, ISO9001, FM, WRAS, SIL, and PED for global compliance.
Customization Available: ODM and OEM services available with customization from client designs.
Reliable Sealing: NBR or EPDM seals ensure tight closing and prevent leakage effectively.
Company profile
CertifiedBusiness Type: Manufacturer/Factory & Trading Company CertifiedR&D Capacity: ODM Service Available & OEM Service Available CertifiedCustomization Options: Customization from Designs CertifiedExport Year: N/A CertifiedNearest Port: Shanghai PortAverage Response Time: ≤1.99h
About Our Factory & Business Background
AddressNo. 111 Huangjia Garden Road, Jiangqiao Town, Jiading District, Shanghai, China
Plant Area12819.22 square meters
Number of Employees81
Registered Capital55,484,089 RMB
Terms of PaymentLC, T/T, D/P, PayPal, Western Union, Small-amount payment
International Commercial Terms(Incoterms)FOB, CIF, CFR, EXW
Average Lead TimePeak Season Lead Time: within 15 workdays Off Season Lead Time: within 15 workdays
Minimum Order Quantity500 PICS
Supply Chain Partners12
Our Production Capability & Technical Expertise
Main Productsangle valve
Production Lines5
Production MachinesCNC Lathe, Lathe, Shot Blasting Facility, Vertical Lathe
QA/QC inspectors3 people
Inspection Type for Finished Products100% inspection(Visual inspection & Function inspection)
Inspection Method for Finished ProductsHave instructions and uniformly followed
R&D Engineers2 people
Traceability of Raw MaterialsYes
Our Industry Experience & Global Business Record
Year of Establishment2001-03-20
Main MarketsDomestic
Repeat Buyers Choice50%~80%
Number of Foreign Trading Staff4
Overseas Agent/BranchNo
New Products Launched in Last yearNo
Our Certifications, Standards & Industry Recognition
Cooperated with Fortune 500No
Product Q&A
Q:How to choose the right backflow preventer for water systems?
A:
For potable systems, RPZ backflow preventers are ideal for high-risk scenarios. Consider pipeline size, pressure, and risk level. Double check valves suit lower risks, while RPZ offers top protection.
Q:Why are backflow preventers crucial in municipal and building water systems?
A:
Backflow preventers are vital for protecting drinking water from contamination due to back pressure or siphonage. They are required by most municipal codes and in high-rise buildings to safeguard public health and prevent cross-connection hazards.
Q:Can backflow preventers be used in fire protection systems?
A:
Yes. Specialized backflow preventers are integral to fire protection systems, preventing non-potable water from entering the municipal supply. They ensure safety and compliance with fire protection and drinking water standards.
Q:How do backflow preventers improve safety in HVAC and industrial water systems?
A:
Backflow preventers shield chilled water, heating, and process water systems from reverse flow contamination. They preserve water quality, prevent equipment corrosion, and ensure regulatory compliance in commercial and industrial facilities.
Q:What is the minimum order quantity?
A:
The minimum order quantity is 500 pieces.
Send Inquiry
*To:
Shanghai Zentif Valve Group Co., Ltd.
Shanghai Zentif Valve Group Co., Ltd.*Content:
Supplier replies will be sent to your registered email
You may also like
Ductile Iron Grooved Backflow Preventer with UL/FM Certified
US$50.00-1,000.00
100 Pieces(MOQ)
Casting Iron Grooved Valve Backflow Preventer for Fire Protection System Use
US$50.00-1,000.00
100 Pieces(MOQ)
Brass Rpz Backflow Preventer Reduced Pressure Zone Assembly for High Hazard Applications
US$3.85-4.00
500 Pieces(MOQ)
Cast Iron Grooved Backflow Preventer Check Valve for Water
US$50.00-1,000.00
100 Pieces(MOQ)
Brass Backflow Preventer for HVAC/Irrigation/Fire Protection Dual Check Valve for Commercial Systems
US$3.85-4.00
500 Pieces(MOQ)
Brass Anti-Siphon Backflow Preventer Atmospheric Vacuum Breaker for Irrigation/Hydrants
US$3.85-4.00
500 Pieces(MOQ)
Premium Brass Dual Check Backflow Preventer for Safe Water Supply
US$3.85-4.00
500 Pieces(MOQ)
Popular Reverse Flow Preventer Made in China
US$799.68-899.58
5 Pieces(MOQ)
Main Pipeline Backflow Preventer for Branch Water Supply Connections
US$30.00-60.00
5 Pieces(MOQ)
Corrosion Resistance FRP Flap Gate Fiberglass Preventer
US$95.00-100.00
50 Sets(MOQ)
Wholesale Vertical Stainless Steel Low Resistance Backflow Preventer for Potable Water Systems
US$65.00-100.00
1 Piece(MOQ)
High-Quality Backflow Preventer for DN100 and DN150 Flanged Connections
US$300.00-400.00
5 Pieces(MOQ)
New Design Stainless Steel Low Resistance Backflow Preventer for Potable Water Systems
US$65.00-100.00
1 Piece(MOQ)
High Performance Ductile Iron DN50~DN300 Backflow Preventer
US$50.00-5,000.00
20 Pieces(MOQ)
Main Difference Between Rpz and Double Check Type Backflow Preventer Fully Explained
US$200.00-300.00
1 Piece(MOQ)
Stainless Steel Integrated Backflow Preventer (GADF41X)
US$1.00
1 Piece(MOQ)
Reduced Pressure Zone Rpz Backflow Preventer for Preventing Water Medium Reverse Flow
US$300.00-400.00
5 Pieces(MOQ)
Wholesale Vertical Stainless Steel Low Resistance Backflow Preventer for Water Supply Systems
US$65.00-100.00
1 Piece(MOQ)
High Quality Ductile Iron Pn16 Pn25 Backflow Preventer
US$50.00-5,000.00
20 Pieces(MOQ)