Product profile

Customization

Available

Media

Water

Temperature

Ordinary Temperature

Model NO.

LHS743X-16Q-DN100

Material

Cast Iron

Connection Form

Flange

Structure

Double Check with Relief Valve

Pressure

Ordinary Pressure

Function

Backflow Prevention and Water Supply Isolation

Sealing Form

Soft Sealing

Flow Direction

Unidirection

Standard

GB

Application

Water Industrial Usage

Product Name

Low-Resistance Backflow Preventer

Model

Lhs743X

Valve Type

Backflow Preventer

Nominal Diametre

DN50-300

Nominal Pressure

Pn10-16

Working Temperature

0℃ ~ 80℃

Valve Body

Ductile Iron

Internal Component

Stainless Steel

Advantages-01

High Safety Backflow Protection

Advantages-02

Prevents Contamination & Water Hammer

Certification

GS, CE, ISO9001

Transport Package

Seaworthy Wooden Case

Specification

DN50-DN300

Trademark

Zentif

Origin

China

HS Code

8421199090

Production Capacity

50000

Key features

Robust Backflow Protection: Dual check valves with auto-draining relief valve prevent contamination and water hammer.
High Durability Materials: Ductile iron body and stainless steel internal components resist corrosion and ensure longevity.
Energy Efficient Design: Low resistance and streamlined flow reduce head loss and pump energy consumption.
Wide Application Scope: Suitable for municipal water, fire protection, HVAC, and industrial water systems.
Hydraulic Operation: Fully hydraulic operation requires no external power source for reliable performance.
Certified Quality: Products hold GS, CE, ISO9001, and other international certifications for safety.
Customizable Specifications: Nominal diameter DN50-300 and pressure Pn10-16 available for specific project needs.
Strict Quality Control: 100% visual and function inspection ensures every product meets high standards.

Company profile

Shanghai Zentif Valve Group Co., Ltd.
Importers and ExportersHigh Repeat Buyers ChoiceIn-stock CapacityFast Delivery
CertifiedBusiness Type: Manufacturer/Factory & Trading Company CertifiedR&D Capacity: ODM Service Available & OEM Service Available CertifiedCustomization Options: Customization from Designs CertifiedExport Year: N/A CertifiedNearest Port: Shanghai PortAverage Response Time: ≤1.91h

About Our Factory & Business Background

AddressNo. 111 Huangjia Garden Road, Jiangqiao Town, Jiading District, Shanghai, China
Plant Area12819.22 square meters
Number of Employees81
Registered Capital55,484,089 RMB
Terms of PaymentLC, T/T, D/P, PayPal, Western Union, Small-amount payment
International Commercial Terms(Incoterms)FOB, CIF, CFR, EXW
Average Lead TimePeak Season Lead Time: within 15 workdays Off Season Lead Time: within 15 workdays
Minimum Order Quantity500 PICS
Supply Chain Partners12

Our Production Capability & Technical Expertise

Main Productsangle valve
Production Lines5
Production MachinesCNC Lathe, Lathe, Shot Blasting Facility, Vertical Lathe
QA/QC inspectors3 people
Inspection Type for Finished Products100% inspection(Visual inspection & Function inspection)
Inspection Method for Finished ProductsHave instructions and uniformly followed
R&D Engineers2 people
Traceability of Raw MaterialsYes

Our Industry Experience & Global Business Record

Year of Establishment2001-03-20
Main MarketsDomestic
Repeat Buyers Choice50%~80%
Number of Foreign Trading Staff4
Overseas Agent/BranchNo
New Products Launched in Last yearNo

Our Certifications, Standards & Industry Recognition

Cooperated with Fortune 500No

Product Q&A

Q:How to select the right backflow preventer for water supply systems?
A:
For potable systems, RPZ preventers suit high-risk. Check size, pressure, hazard. Double check valves for lower risk; RPZ offers top protection.
Q:Why are backflow preventers crucial in municipal and building water systems?
A:
Backflow preventers protect drinking water from contamination by back pressure or siphonage, as mandated by municipal codes and high-rise buildings to ensure public health and prevent cross-connection risks.
Q:Can backflow preventers be utilized in fire protection systems?
A:
Yes. Specialized backflow preventers ensure non-potable water doesn't mix with municipal supply, maintaining safety and compliance with fire and drinking water standards.
Q:How do backflow preventers enhance safety in HVAC and industrial water systems?
A:
Backflow preventers safeguard chilled, heating, and process water systems from contamination. They preserve water quality, prevent equipment corrosion, and ensure adherence to health and safety regulations in commercial and industrial environments.
Q:What is the minimum order quantity for this product?
A:
The minimum order quantity is 500 pieces.

Send Inquiry

*To:Shanghai Zentif Valve Group Co., Ltd.Shanghai Zentif Valve Group Co., Ltd.
*Content:
0/4000

Supplier replies will be sent to your registered email

You may also like

2inch-24inch Swing Check Valve CF8/CF8m Flange End
Made-in-China.com
Tilting Single Disc Double Flanged Type Check Valve
Made-in-China.com
API 6D NPT Ends Forging Axial Flow Check Valve
Made-in-China.com