Powered by Made-in-China.com

Self-Operated Backflow Preventer for Water Meter Outlet Installation
US$30.00-60.00
5 Pieces
Sample price:US$200.00/piece.Request sample
Product profile
Customization
AvailableMedia
WaterTemperature
Ordinary TemperatureModel NO.
HS41XMaterial
Cast IronConnection Form
FlangeStructure
Dual Check with Intermediate Relief AssemblyPressure
Ordinary PressureFunction
Backflow Prevention and Water Supply IsolationSealing Form
Soft SealingFlow Direction
UnidirectionStandard
GBApplication
Water Industrial UsageProduct Name
Reduced Pressure Zone Backflow PreventerModel
HS41XValve Type
Backflow PreventerNominal Diametre
DN50-300Nominal Pressure
Pn10-16Working Temperature
0℃ ~ 80℃Valve Body
Ductile IronInternal Component
Stainless SteelAdvantages-01
High Safety Backflow ProtectionAdvantages-02
Prevents Contamination & Water HammerCertification
GS, CE, ISO9001Transport Package
Seaworthy Wooden CaseSpecification
DN50-DN300Trademark
ZentifOrigin
ChinaHS Code
8421199090Production Capacity
50000Key features
Multi-Stage Backflow Protection: RPZ structure offers multiple levels of protection against backpressure and back-siphonage.
Dual Check with Relief Assembly: Manages normal flow while automatically discharging abnormal pressure centrally.
Corrosion Resistant Materials: Ductile iron body with stainless steel stems and springs for long-lasting durability.
Self-Operated Operation: Functions without electricity or external actuators for reliable performance.
Wide Size Range: Available in sizes from DN50 to DN300 to fit various pipeline requirements.
Reliable Sealing: NBR/EPDM seals ensure tight closure and prevent leakage under pressure.
Certified Safety: Meets GS, CE, and ISO9001 standards for industrial and municipal applications.
Customization Available: ODM and OEM services available with customization from customer designs.
Company profile
CertifiedBusiness Type: Manufacturer/Factory & Trading Company CertifiedR&D Capacity: ODM Service Available & OEM Service Available CertifiedCustomization Options: Customization from Designs CertifiedExport Year: N/A CertifiedNearest Port: Shanghai PortAverage Response Time: ≤1.99h
About Our Factory & Business Background
AddressNo. 111 Huangjia Garden Road, Jiangqiao Town, Jiading District, Shanghai, China
Plant Area12819.22 square meters
Number of Employees81
Registered Capital55,484,089 RMB
Terms of PaymentLC, T/T, D/P, PayPal, Western Union, Small-amount payment
International Commercial Terms(Incoterms)FOB, CIF, CFR, EXW
Average Lead TimePeak Season Lead Time: within 15 workdays Off Season Lead Time: within 15 workdays
Minimum Order Quantity500 PICS
Supply Chain Partners12
Our Production Capability & Technical Expertise
Main Productsangle valve
Production Lines5
Production MachinesCNC Lathe, Lathe, Shot Blasting Facility, Vertical Lathe
QA/QC inspectors3 people
Inspection Type for Finished Products100% inspection(Visual inspection & Function inspection)
Inspection Method for Finished ProductsHave instructions and uniformly followed
R&D Engineers2 people
Traceability of Raw MaterialsYes
Our Industry Experience & Global Business Record
Year of Establishment2001-03-20
Main MarketsDomestic
Repeat Buyers Choice50%~80%
Number of Foreign Trading Staff4
Overseas Agent/BranchNo
New Products Launched in Last yearNo
Our Certifications, Standards & Industry Recognition
Cooperated with Fortune 500No
Product Q&A
Q:Selecting the right backflow preventer for water supply?
A:
For potable systems, RPZ backflow preventers are best for high-risk areas. Consider pipeline size, pressure, and hazard level. Double check valves suit lower risk; RPZ offers max protection.
Q:Why are backflow preventers essential in municipal and building water systems?
A:
Backflow preventers are crucial safety devices that shield drinking water from contamination due to back pressure or siphonage. Required by most municipal codes and high-rise buildings, they protect public health and prevent cross-connection risks.
Q:Can backflow preventers be used in fire protection systems?
A:
Yes. Specialized backflow preventers are used in fire protection systems to stop non-potable water from reversing into the municipal supply, ensuring safety per fire protection and water standards.
Q:How do backflow preventers improve safety in HVAC and industrial water systems?
A:
Backflow preventers secure chilled water, heating, and process systems from reverse flow contamination, maintaining water quality, preventing equipment corrosion, and ensuring safety compliance in commercial and industrial setups.
Send Inquiry
*To:
Shanghai Zentif Valve Group Co., Ltd.
Shanghai Zentif Valve Group Co., Ltd.*Content:
Supplier replies will be sent to your registered email
You may also like
Lead-Free Brass Backflow Preventer, Double Check Valve for Drinking Water
US$3.85-4.00
500 Pieces(MOQ)
Cast Iron Grooved Backflow Preventer Check Valve for Water
US$50.00-1,000.00
100 Pieces(MOQ)
Premium Brass Dual Check Backflow Preventer for Safe Water Supply
US$3.85-4.00
500 Pieces(MOQ)
Brass Anti-Siphon Backflow Preventer Atmospheric Vacuum Breaker for Irrigation/Hydrants
US$3.85-4.00
500 Pieces(MOQ)
Brass Backflow Preventer for HVAC/Irrigation/Fire Protection Dual Check Valve for Commercial Systems
US$3.85-4.00
500 Pieces(MOQ)
Casting Iron Grooved Valve Backflow Preventer for Fire Protection System Use
US$50.00-1,000.00
100 Pieces(MOQ)
Ductile Iron Grooved Backflow Preventer with UL/FM Certified
US$50.00-1,000.00
100 Pieces(MOQ)
Popular Reverse Flow Preventer Made in China
US$799.68-899.58
5 Pieces(MOQ)
Corrosion Resistance FRP Flap Gate Fiberglass Preventer
US$95.00-100.00
50 Sets(MOQ)
Horizontal Mounted Backflow Preventer Easy Installation for Plumbing Pipeline System
US$300.00-400.00
5 Pieces(MOQ)
DN100 Flanged Backflow Preventer for Municipal Water Supply Pipeline Systems
US$300.00-400.00
5 Pieces(MOQ)
Wholesale Vertical Stainless Steel Low Resistance Backflow Preventer for Potable Water Systems
US$65.00-100.00
1 Piece(MOQ)
New Design Stainless Steel Low Resistance Backflow Preventer for Potable Water Systems
US$65.00-100.00
1 Piece(MOQ)
High Quality Ductile Iron DN50 Pn16 Backflow Preventer
US$50.00-5,000.00
20 Pieces(MOQ)
Large Caliber Backflow Preventer DN200 DN250 for Large Water Engineering Projects
US$200.00-300.00
1 Piece(MOQ)
Stainless Steel Low Resistance Backflow Preventer
US$1.00
1 Piece(MOQ)
Industrial Backflow Preventer Non Return Valve for Inline Water Systems
US$300.00-400.00
5 Pieces(MOQ)
Wholesale Vertical Stainless Steel Low Resistance Backflow Preventer for Water Supply Systems
US$65.00-100.00
1 Piece(MOQ)
High Performance Ductile Iron DN50~DN300 Backflow Preventer
US$50.00-5,000.00
20 Pieces(MOQ)