SourcingAI

Carbon and sulfur analyzer

I have found results from10000+products and4000+suppliers aboutCarbon and sulfur analyzer

Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Infrared Absorption Analyzer
Type: Measurement Type
Element: Metals Analyzer
Display: Computer Screen
Ceramics and Glass
Frequency: 50±1HZ
Performance: Automation
Function: Storage
Weight: 0-100Kg
Power Source: AC220V±22V
Customized: Customized
Analysis: Infrared Analysis
Portable: Portable
Gas: SO2
The Analysis of Environmental Samples
Gamma Ray Spectrometer
Gaspath System: Single
Detector: TCD
Energy Resolution: ≤7%
Certification: CE
Spectrometer Detector: SDD
Stationary Phase: Liquid Solvent
Mobile Phase: Liquid
Chromatography Type: Liquid Chromatography
Convetional Analytical Column
Chromatographic Column Length: 10~30cm
Chromatographic Column Diameter: 20~40mm
Accuracy Grade: 1
Load Way: Electronic Load
Loading Method: Dynamic Load
Control: Computer Control
Structure: Desktop
Material: Steel
Display: Digital
Application: Metal
Application: School
Application: Lab
Frequency: 50±0.5Hz
Performance: Semi-automatic
Function: Cleared
Weight: 100-500Kg
Power Source: AC220V
Customized: Non-Customized
Certification: ISO
Certification: IEC
Certification: GMP
Certification: RoHS

Sourcing guidance for Carbon And Sulfur Analyzer

What are the key technical specifications to consider when selecting a Carbon and Sulfur Analyzer?

Buyers should prioritize the detection limit and precision, typically requiring a sensitivity of 0.1ppm or lower for high-end applications. Ensure the device utilizes High-Frequency Induction Combustion combined with Infrared (IR) Absorption Detection for the most accurate results. Additionally, check the linearity range to ensure it covers your specific material concentrations, whether for steel, alloys, or ores.

Which international compliance standards are essential for these analytical instruments?

The equipment must adhere to ISO 15350 for the determination of carbon and sulfur in steel and iron. For safety and electronic reliability, ensure the supplier provides CE Certification and ISO 9001 Quality Management System documentation. If the unit includes a furnace, it should meet IEC 61010-1 safety requirements for electrical equipment for measurement and laboratory use.

What are the typical usage scenarios and material compatibility requirements?

These analyzers are primarily used in metallurgy, foundry, and aerospace industries for quality control. It is vital to confirm that the instrument is compatible with your specific samples, such as cast iron, stainless steel, copper alloys, or ceramics. Ask the supplier for application notes or test reports specific to your material matrix to ensure the combustion catalysts (like tungsten or tin) are optimized for your needs.

How should a buyer evaluate the long-term economic feasibility and maintenance?

Beyond the initial purchase price, calculate the cost per analysis, which includes the consumption of high-purity oxygen (99.95%+), crucibles, and chemical reagents like magnesium perchlorate. Look for suppliers on Made-in-China.com that offer self-diagnostic software and modular designs, which significantly reduce downtime and the need for expensive on-site technician visits.

Cross-Border Procurement & Risk Management for Analytical Instruments

What are the primary risks when importing high-precision laboratory equipment?

The main risks include transportation damage to sensitive optical components and customs delays due to missing calibration certificates. To mitigate this, insist on vacuum-sealed anti-static packaging and reinforced wooden crates. Ensure the seller provides a Certificate of Calibration and a detailed HS Code (typically 9027.10) classification to avoid tariff disputes.

How can I ensure transaction security and supplier reliability?

Utilize the Secured Trading services provided by Made-in-China.com to protect your payment until the goods are shipped. Conduct a factory audit or request a third-party inspection (such as SGS or Bureau Veritas) to verify the supplier's production capacity and the existence of a professional R&D laboratory.

What strategies should be used for negotiating with specialized equipment suppliers?

Focus negotiations on after-sales technical support and spare parts packages rather than just the unit price. Request a 2-year warranty and a guaranteed supply of consumables (cruibles and accelerators) at a fixed price for the first 24 months. For bulk orders, aim for a 10-15% discount or the inclusion of a high-end analytical balance as a bundle.

What are the logistics considerations for shipping to international destinations?

Due to the precision of the infrared cells, Air Freight is highly recommended over sea freight to minimize vibration and humidity exposure. Ensure the shipping terms are clearly defined under Incoterms 2020 (e.g., DAP or CIF). If the analyzer contains small amounts of chemical reagents, verify if they are classified as Dangerous Goods and require special handling documentation.

Related queries