Chlorine sensor
I have found results from10000+products and4000+suppliers aboutChlorine sensor
Advanced Chlorine Sensor for Accurate Water Quality Testing Membrane Principle
High-Performance IP68 Chlorine Sensor with Constant Voltage Technology
High-Precision Residual Chlorine Sensor for Swimming Pool Chlorine Metering
Endress+Hauser\E+H Digital Free Chlorine Sensor Memosens CCS51d
Free & Total Chlorine of Liquid Instrument Sensors, Probe, Electrode, Digital
Free & Total Chlorine of Liquid Instrument Sensors Use in Drinking Water, Probe, Electrode, Digital (RS11-D009)
Online Residual Chlorine Sensor with Free Membrane Cap and Electrolyte
Online Residual Chlorine Sensor RS485 Reagent-Free Chlorine Analyzer for Smart Water Monitoring System
Surfactant Resistant Free Chlorine Water Sensor for Drinking Water Wastewater and Sewage
Online 4-20mA 0-2ppm Drinking Water Free Chlorine Sensor with Transmitter
Pressure Resistant Free Chlorine Water Sensor with W519 Multi-Parameter Controller
High Concentration Free Chlorine Sensor with Online Transmitter for Food Washing
MDS-800RC Residual Chlorine Sensor Suitable For Various Harsh Working Environments
ORP, pH, DO, Turbidity, Ammonia-Nitrogen, Residual chlorine, EC,COD,BOD Oil-in-water Sensor/probe/electrode
Professional Online Residual Chlorine Sensor RS485 Output for Industrial Wastewater Monitoring
Bh-485-Cl Online Water Treatment Digital Residual Chlorine Sensor Probe Electrode for Saline Chlorination System
Electric Detection Measure Chemical Me3-Cl2 Chlorine Gas Sensor
Disinfection Sensor Digital Residual Chlorine Free Chlorine Dissolved Ozone Chlorine Dioxide Sensor
RS485 Chlorine Meter Sensor O3 Residual Chlorine Probe
Constant Pressure Residual Chlorine Electrode Residual Chlorine Sensor
Multi-Parameter Water Temperature Dissolved Oxygen Ec Residual Chlorine Ammonia Water Quality Sensor
Low Cost RS485 Output Online Electrode Water Free Chlorine Sensor for Pool
Chlorine Dioxide Sensor Probe Clo2 Detection Module Clo2 High Precision Gas Intelligent Sensor
Sourcing guidance for Chlorine Sensor
What are the key technical specifications to consider when selecting a chlorine sensor for industrial use?
When sourcing chlorine sensors, you must prioritize the measurement range (typically 0-20 ppm for water treatment) and resolution (ideally 0.01 ppm). Ensure the sensor utilizes amperometric or potentiometric technology for real-time monitoring. It is crucial to verify the response time (T90), which should be less than 60 seconds for safety-critical applications. Additionally, look for automatic temperature compensation (ATC) features, as chlorine concentration readings are highly sensitive to temperature fluctuations.
Which compliance standards and certifications are mandatory for international procurement?
For global trade, the sensor must hold CE marking for European markets and FCC/UL certification for North America. If the sensor is used in drinking water applications, look for NSF/ANSI 61 certification. For hazardous environments, ATEX or IECEx explosion-proof certification is mandatory. Ensure the supplier provides a Certificate of Analysis (CoA) and adheres to ISO 9001 quality management systems to guarantee batch consistency.
How do usage scenarios dictate the choice between 'Free Chlorine' and 'Total Chlorine' sensors?
Free Chlorine sensors are best suited for swimming pools and drinking water disinfection where immediate germicidal power is measured. Total Chlorine sensors (which include combined chlorine) are necessary for wastewater treatment and cooling towers to ensure environmental discharge compliance. Choosing the wrong type can lead to inaccurate dosing of chemicals, resulting in either regulatory fines or inadequate disinfection.
What are the maintenance requirements and lifespan expectations for these sensors?
Professional-grade chlorine sensors typically have a lifespan of 12 to 24 months for the sensing electrode or membrane. You should inquire if the supplier offers replaceable membrane caps and electrolyte solutions to extend the unit's life. Calibration frequency is also a key factor; high-quality sensors should maintain stability for at least 30 days between calibrations to reduce operational labor costs.
Cross-Border Procurement Strategy & Risk Management
What are the primary risks when importing chlorine sensors and how can they be mitigated?
The main risk is sensor degradation during transit, especially for wet-cell sensors. Ensure the supplier uses hermetic, anti-static packaging and climate-controlled shipping if necessary. To mitigate transaction risks, use Secured Trading Services on Made-in-China.com, which protects your payment until the goods are verified. Always request a pre-shipment inspection (PSI) to verify that the sensors meet the agreed-upon technical accuracy benchmarks.
How should I negotiate with suppliers to ensure long-term value?
Focus on the Total Cost of Ownership (TCO) rather than just the unit price. Negotiate for tiered pricing (e.g., 5-10% discounts for orders over 50 units) and ask for free calibration kits or spare membranes to be included in the initial bulk order. Demand a warranty period of at least 12 months and clarify the RMA (Return Merchandise Authorization) process for defective units to avoid high return shipping costs.
What logistics and customs considerations apply to chlorine sensors?
Chlorine sensors containing electrolyte liquids may be classified as 'Sensitive Goods' or Class 8 Corrosives depending on the chemical composition. You must confirm that the supplier provides a Material Safety Data Sheet (MSDS) and a UN38.3 test report if the device includes lithium batteries. For shipping to the US or EU, ensure the HS Code (typically 9027.80) is correctly declared to avoid customs delays and ensure the correct tariff rates are applied.





























