Crt oscilloscope
I have found results from20+products and10suppliers aboutCrt oscilloscope
3.5mm Trs Audio Plug to 3 BNC Female Splitter Cable
Twintex Tos-2020CT China 20MHz Analog Oscilloscope Component Tester with CRT
Wintex Tos-2020CT Double Channel Analog Oscilloscope with Good Price
Twintex Dual Channel Made in China 30MHz Cathode Ray Oscilloscope
Twintex Tos-2040CT Stuendent Laboratory Use Dual 40MHz Oscilloscope with Component Tester
Dual Trace Cathode Ray Analog Oscilloscope 20MHz with Frequency Counter
Twintex Tos-2020CH Laboratory Dual Channel Cro Analog Oscilloscope 20MHz for Students
Twintex Component Test Function 20MHz 30MHz 40MHz Two Channel Cathode Ray Oscilloscope Analog
Twintex Tos-2030CF Cro Dual Channel Oscilloscope 30MHz with Frequency Counter
Twintex Dual Trace Electronic Laboratory CRT 40MHz Analog Oscilloscope
Twintex Tos-2040CF Analogue Oscilloscope 40MHz with Frequency Counter
Made in China CRT Display Dual Trace 2CH+ 40MHz 220V Oscilloscope with Frequency Counter
Twintex Tos-2100c Delayed Sweep Dual Channel CRT Analog Oscilloscope 100MHz
Mch 30MHz Dual Channel Handheld Analog Oscilloscope (V-5030)
40MHz Portable Oscilloscope Dual Channel Oscilloscope Low Cost Analog Oscilloscope (MCH V-5040)
Three Channel Six Tracking Analog Oscilloscope 40MHz 60MHz with Delayed Sweep Function V-5040d V-5060d
Dual Channels Dual Traces 20m Analog Oscilloscope with Digit Frequency Meter V-212A V-252A
Sourcing guidance for Crt Oscilloscope
What are the key technical specifications to consider when selecting a CRT Oscilloscope for industrial or educational use?
When sourcing a CRT (Cathode Ray Tube) oscilloscope, the most critical factor is the Bandwidth (typically 20MHz to 100MHz), which determines the maximum frequency signal the device can accurately measure. You must also evaluate the Rise Time, as it should be significantly faster than the signal's fastest transition. For multi-signal analysis, ensure the unit has at least Dual Channels (CH1 & CH2) with an Add/Subtract algebraic mode. Additionally, check the Vertical Sensitivity (e.g., 5mV to 5V/div) and Sweep Time (e.g., 0.1uS to 0.2S/div) to ensure the display resolution meets your specific waveform analysis requirements.
How do I verify the quality and longevity of the CRT display itself?
The CRT is the most vulnerable component. Ensure the supplier uses a High-Brightness, Internal Graticule CRT with an acceleration voltage of at least 2kV (for 20MHz) to 14kV (for 100MHz) to ensure clear traces even at high sweep speeds. Ask for the Phosphor type (usually P31) and verify if the unit includes a Trace Rotation adjustment to compensate for the Earth's magnetic field. A quality CRT should have a sharp focus and consistent intensity across the entire 8x10 division screen area.
What compliance and safety standards are mandatory for electronic testing equipment?
For international trade, the product must adhere to IEC 61010-1 safety requirements for electrical equipment for measurement and control. Ensure the supplier provides CE Marking for the European market and UL or ETL certification for North America. Since these devices contain high-voltage components, verify that the housing is properly grounded and that the power supply supports Universal Voltage (110V/220V AC) with appropriate fuse protection.
What are the typical usage scenarios for CRT oscilloscopes versus modern digital models?
CRT (Analog) oscilloscopes are preferred for Real-time Waveform Display without the aliasing or quantization noise found in low-end digital models. They are ideal for Educational Laboratories, Audio Equipment Repair, and Analog Circuit Design where observing the 'intensity' of the trace provides insight into signal jitter or noise. They are also highly valued in Legacy System Maintenance where high-speed digital sampling is not required but signal fidelity is paramount.
Cross-Border Procurement & Risk Management for CRT Oscilloscopes
How should I handle the fragile nature of CRT oscilloscopes during international shipping?
CRT oscilloscopes contain vacuum tubes made of glass, making them extremely sensitive to mechanical shock. You must mandate Double-Box Packaging with at least 5cm of high-density EPE foam padding on all sides. Request the supplier to use 'Fragile' and 'Handle with Care' labels in both English and the destination language. For bulk orders, Palletization with Shrink Wrap is highly recommended to prevent individual box drops during transit.
What are the risks of purchasing 'New Old Stock' (NOS) or refurbished CRT units?
Many CRT oscilloscopes are no longer in mass production. The primary risk is Capacitor Aging or Cathode Poisoning in units that have sat idle for years. Before finalizing a deal on Made-in-China.com, require the supplier to provide a Video Functional Test showing the unit passing a self-calibration check (Cal 0.5V p-p square wave). Ensure the Warranty Period is at least 12 months, covering both the CRT tube and the power board.
How can I negotiate better terms and ensure transaction security with suppliers?
When negotiating, leverage the Order Volume; even for niche analog equipment, a 10-unit order can often trigger a 10-15% discount. To secure your transaction, always use Trade Assurance services provided by platforms like Made-in-China.com to protect your payment until the goods are verified. Request a Pre-shipment Inspection (PSI) by a third party to verify that the technical specs match the Proforma Invoice.
What should I consider regarding customs and import duties for electronic test instruments?
Verify the HS Code (typically 9030.20) for oscilloscopes to calculate accurate import duties in your country. Be aware that some regions have specific Electronic Waste (WEEE) regulations or RoHS compliance requirements. Ensure the supplier provides a detailed Commercial Invoice and Packing List that matches the physical goods to avoid lengthy customs delays or seizures.