SourcingAI

Dc high voltage generator

I have found results from100000+products and30000+suppliers aboutDc high voltage generator

Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Universal Testing Machine
Basic Diesel Generator
Compression Testing Machine
Pulse Signal Generator
Strength Testing Machine
Micro-Computer Control Automatic Diesel Generator
Self-Starting Diesel Generator
Display: Digital
General Installation Meter
Accuracy: 1
Power Source: DC Meter
Theory: Electronic Meter
Application: Electronic Equipment
Customized: Customized
Max Diameter of Workpiece: <500mm
Mass Scope of Workpiece: <900kg
Maxcapacity: <1000KN
Accuracy Grade: 0.5
Load Way: Electronic Load
Loading Method: Dynamic Load
Control: Computer Control
Weight: 0-100Kg
Oil Cylinder Position: Under
Installation Method: Fixed
Stroke: Four Stroke
Cooling Method: Water Cooling
AC Three Phase
Speed: Speed
Conditions of Use: Land Use
Usage: Common Units
Landuse Type of Unit: Ordinary
AC Rotating Exciter
Channel: 3
Certification: RoHS
Display Type: Digital Only
Protection: Shock Resistance
Display: TFT
Display: LCD
Power Source: AC220V
Application: Electric Power
Max Diameter of Workpiece: >3200mm
Accuracy Grade: 1
Load Way: Mechanical Load
Loading Method: Static Load
Control: Manual Control
Weight: 100-500Kg
Oil Cylinder Position: Top
Speed: Low Speed
Usage: Standby Unit
Usage: Emergency Crew
Low Noise Automation Type
Landuse Type of Unit: Automation Type
Excitation Mode: Static Exciter
Certification: CE
Certification: ISO9001

Sourcing guidance for Dc High Voltage Generator

What are the key technical specifications to evaluate when sourcing a DC High Voltage Generator?

Buyers must prioritize Voltage Stability (Ripple Factor), which should ideally be ≤0.5% to ensure precision in testing. The Voltage Measurement Accuracy should reach ±(1.0% reading + 2 digits). Additionally, verify the Rated Output Voltage (e.g., 60kV, 120kV, or 300kV) and Rated Current to ensure they meet your specific insulation testing or electrostatic application requirements. Look for units featuring ZGF (Zero-crossing Voltage Start) technology to protect both the equipment and the operator.

Which safety and compliance standards are mandatory for international procurement?

Ensure the product carries the CE Mark for European market access and complies with IEC 60060 (High-voltage test techniques). For the North American market, UL or ETL certification is preferred. The manufacturer should hold an ISO 9001:2015 quality management certification. It is critical that the device includes Over-voltage, Over-current, and Zero-start protection mechanisms to prevent catastrophic failure during dielectric strength tests.

How does the cooling system and structural design impact long-term reliability?

For high-power applications, choose generators with Oil-immersed or SF6 gas-insulated high-voltage cylinders for superior heat dissipation and insulation. For portable field testing, Dry-type (Epoxy resin) cylinders are preferred due to their lightweight and leak-proof nature. Ensure the control box and the voltage doubler are modularly designed to facilitate easier maintenance and component replacement.

What are the typical usage scenarios for industrial-grade DC High Voltage Generators?

These units are primarily used for DC withstand voltage tests and leakage current measurements of power cables, surge arresters, and power transformers. They are also essential in electrostatic spraying, dust precipitation, and scientific research involving particle acceleration. Selecting a model with a polarity switching function is vital if your testing protocols require both positive and negative high-voltage outputs.

Cross-Border Procurement Strategy & Risk Management

How can I mitigate the risks of purchasing high-precision electrical equipment from overseas?

Utilize Made-in-China.com's 'Secured Trading' services to ensure payment is only released upon confirmation of receipt. Request a Factory Acceptance Test (FAT) video or hire a third-party inspector (like SGS or Intertek) to verify the actual output voltage against the digital display before the balance payment is made. This prevents receiving 'hollow' units that do not meet rated specifications.

What are the best practices for shipping sensitive high-voltage equipment internationally?

Due to the sensitive electronics and potential pressurized gas (if SF6 is used), the equipment must be packed in IPPC-certified fumigated wooden crates with shock-absorbent foam lining. Clearly label the package as 'Fragile: Precision Instrument'. For air freight, ensure the supplier provides a Non-Dangerous Goods Declaration if the unit contains oil or gas, as these are subject to strict IATA regulations.

How should I negotiate technical support and warranty terms with a foreign supplier?

Negotiate a minimum 24-month warranty period. Since returning heavy high-voltage cylinders is costly, insist on a clause where the supplier provides free replacement PCB boards or control modules via express air courier in case of failure. Demand English-language operation manuals and, if possible, video-call technical training as part of the purchase agreement to ensure your local engineers can calibrate the device correctly.

What customs and trade policy factors should be considered?

Check the HS Code (typically 8543.70) for import duties in your country. Be aware of Anti-Dumping Duties that may apply to specific electrical components. Ensure the supplier provides a Certificate of Origin (CO) to take advantage of any Free Trade Agreements (FTA) that could significantly reduce your total landed cost.