SourcingAI

Dc resistivity meter

I have found results from3000+products and1000+suppliers aboutDc resistivity meter

Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Energy Meter
Type: PH Meter
Display Type: Digital Only
Customized: Customized
Accuracy Grade: 1
Load Way: Electronic Load
Display: Digital
Control: Computer Control
Certification: RoHS
Appliance: Biochemistry
Accuracy: 1mm
Horizontal Line: 1
Vertical Lines: 1
Power Frequency Suppression: 60dB
Installation: Direct Connected
Multi-Functional Energy Meter
Electric Equipment: Three-phase Four-wire
Theory: Electronic Meter
Power Meter Connection: Terminal
Measured Signal: Continuous Wave
Touch Screen Resolution: 320x420
Humidity: 80%
Data Storage: 100W
Channel: 13
Frequency: Multiple
Detection Depth: 800m
Portable: Non Portable
Certification: CE
Certification: ISO9001
Certification: ISO
Appliance: Food Analysis
Appliance: Medical Research
Vertical Lines: 4
Power Frequency Suppression: 100dB
Meter for Industry and Home Use
Standard Electric Energy Meter
Reactive Energy Meter
Multi-rate Watt-hour Meters
Maximum Demand Meter
Detection Depth: 500m

Sourcing guidance for Dc Resistivity Meter

What are the key technical specifications to evaluate when sourcing a DC Resistivity Meter for geophysical exploration?

Buyers should prioritize measurement precision and resolution, typically requiring a resolution of at least 0.01mV for voltage and 0.01mA for current. Ensure the device supports a wide input impedance (≥50MΩ) to minimize signal loss in high-resistance terrain. Additionally, verify the maximum power supply voltage (often up to 1000V) and current (up to 5A) to ensure deep penetration capabilities for groundwater or mineral exploration.

Which electrode arrays and functions are essential for professional-grade resistivity meters?

A versatile meter must support multiple electrode arrays such as Wenner, Schlumberger, Dipole-Dipole, and Pole-Pole. For high-efficiency projects, look for units with Multi-electrode Resistivity Imaging (ERT) capabilities, which allow for 2D and 3D subsurface mapping. Integrated SP (Self-Potential) compensation and automatic noise filtering are critical for maintaining data integrity in areas with high electromagnetic interference.

What environmental and durability standards should the equipment meet for field operations?

Given the harsh conditions of field work, the device should have an IP67 waterproof and dustproof rating. The operating temperature range should ideally span from -10°C to +50°C. Check for solid-state internal memory to prevent data loss and a high-contrast LCD display that remains readable under direct sunlight. Power management is also key; prioritize systems with rechargeable lithium batteries providing at least 10-15 hours of continuous operation.

How can I ensure the accuracy and compliance of the geophysical data produced?

Ensure the supplier provides a Calibration Certificate traceable to international standards. The equipment should comply with CE and RoHS certifications for electronic safety. For B2B buyers, it is recommended to request case studies or field test reports that demonstrate the meter's performance against known geological structures to verify its inversion software compatibility and data reliability.

Cross-Border Procurement & Risk Management for DC Resistivity Meters

What are the primary risks when importing high-precision geophysical instruments?

The main risks include damage during transit due to the sensitivity of electronic sensors and customs delays caused by improper HS Code classification. Always use the correct HS Code (typically 9030.33) and insist on shock-resistant, vacuum-sealed packaging. Furthermore, ensure the supplier provides comprehensive insurance covering the full value of the goods from factory to port.

How should I negotiate with suppliers on Made-in-China.com to ensure long-term value?

Focus negotiations on after-sales technical support and software updates, as geophysical software often requires periodic patches. Request a 2-year warranty instead of the standard 1-year, and negotiate for the inclusion of spare electrode cables and connectors, which are high-wear items. For bulk orders, aim for a 15-20% discount or free shipping terms under CIF (Cost, Insurance, and Freight).

What transaction security measures are recommended for high-value equipment purchases?

Utilize Secured Trading Services provided by Made-in-China.com to ensure funds are only released upon confirmation of shipment. For large-scale enterprise procurement, consider using a Letter of Credit (L/C) or a 30% deposit / 70% balance payment structure after a successful third-party pre-shipment inspection (PSI) by agencies like SGS or Bureau Veritas.

What are the logistics considerations for shipping devices with internal batteries to international markets?

Since many DC Resistivity Meters contain high-capacity lithium batteries, they are classified as Dangerous Goods (UN3481). Ensure the supplier has the necessary MSDS (Material Safety Data Sheet) and UN38.3 test reports. Choose freight forwarders experienced in handling Class 9 hazardous materials to avoid shipment rejection at the airport or sea port.

Related queries