Dissolved oxygen meter
I have found results from10000+products and6000+suppliers aboutDissolved oxygen meter
Portable Dissolved Oxygen Meter Water Dissolved Oxygen Analyser
CE Water Testing Kit Dissolved Oxygen Controller Do Meter for Aquaculture and Aquarium with Sensor
Low Cost Dissolved Oxygen Meter Do Sensor Water Measuring Device
Boqu Dog 2082X High Accuracy Industrial Dissolved Oxygen Meter
MDS-510DO Online Dissolved Oxygen Meter Touch Screen Adjustable
Dissolved Oxygen Meter Water Treatment Electrical Equipment for Measuring Water Parameters in Aquaculture
Aoda Do310f High Cost-Effective Handheld Water Dissolved Oxygen Do Meter
Portable Dissolved Oxygen Meter for Aquaculture and Water Quality
Economical Dissolved Oxygen Sensor Meter Do Kit for Fish Pond, Drinking Water
Benchtop Dissolved Oxygen Meter with LCD Display Screen
Apure Portable Online Dissolved Oxygen Analysis Meter for Aquarium with Do Sensor
Compact Nobo NPT-Do601y Portable Dissolved Oxygen Meter for Laboratory
Advanced Dnb-160yg Portable Fluorometric Dissolved Oxygen Meter for Aquatic Use
Portable Dissolved Oxygen Analyzer Portable Do Meter
Renke 0~20mg/L Do Sensor Online Modbus Dissolved Oxygen Meter for River Lake
Factory High Accuracy Online Industry Digital Aquarium Dissolved Oxygen Sensor Meter
Cheap Do Sensor Probe Dissolved Oxygen Controller Meter
D0310f Portable Digital Dissolved Oxygen Meter Laboratory Water Optical Dissolved Oxygen Meter
P814 Touch Screen Benchtop Dissolved Oxygen Meter Analyzer
Intelligent Dissolved Oxygen Meter with Touch Screen, USB Export, Bluetooth Printing, Rechargeable Battery IP54 Waterproof
Bi-680 Industrial Portable Online Dissolved Oxygen Controller Meter
Online Water Oxygen Sensor Aguaculture Dissolved Oxygen Meter Controller
Biobase China Portable Dissolved Oxygen Meter pH-820 with Salinity and Barometric Pressure Compensation for Lab
Sourcing guidance for Dissolved Oxygen Meter
How to choose the right sensor technology for a Dissolved Oxygen (DO) Meter?
Buyers must choose between Optical (Luminescence) and Electrochemical (Polarographic/Galvanic) sensors. Optical sensors are highly recommended for long-term stability and low maintenance as they do not require membrane replacement or electrolyte refills and are not affected by H2S interference. Electrochemical sensors are more cost-effective for occasional spot-checking but require regular calibration and a constant flow of water across the membrane to provide accurate readings.
What are the key technical specifications to verify for industrial or laboratory use?
Ensure the device features Automatic Temperature Compensation (ATC), as oxygen solubility varies significantly with temperature. For high-accuracy requirements, look for Salinity and Barometric Pressure Compensation. The measurement range should ideally cover 0 to 20 mg/L (or 0-200% saturation) with an accuracy of ±1% or ±0.1 mg/L. For field use, an IP67 waterproof rating is essential to prevent damage from accidental submersion.
Which compliance standards and certifications are necessary for international trade?
Suppliers should provide CE certification for the European market and FCC for the US. For environmental monitoring or laboratory applications, check for ISO 9001 manufacturing standards and compliance with EPA-approved methods (like ASTM D888-12). If the meter is used in hazardous environments (e.g., oil & gas), ATEX or IECEx explosion-proof certification is mandatory.
What are the typical usage scenarios and how do they affect product selection?
Aquaculture and Fish Farming require portable, rugged meters with long battery life for daily pond checks. Wastewater Treatment Plants prioritize online, continuous monitoring systems with 4-20mA or RS485 Modbus outputs for integration into PLC systems. Laboratory Research demands high-precision benchtop models with data logging capabilities and USB/Bluetooth connectivity for easy data export.
Cross-Border Procurement Considerations for DO Meters
What are the common risks when sourcing high-precision instruments from overseas?
The primary risk is sensor degradation during transit or receiving a unit with a depleted electrolyte/expired membrane. Always request calibration certificates dated within 6 months. To mitigate risks, use Made-in-China.com's Secured Trading services to ensure the product meets technical specifications before final payment is released.
How should I negotiate with suppliers regarding consumables and maintenance?
DO meters are 'razor-and-blade' products. Negotiate for a bundle that includes extra sensor caps, membranes, and electrolyte solutions (for electrochemical models). Ask for a guaranteed supply of replacement parts for at least 5 years to avoid equipment obsolescence. For bulk orders, request a 2-3% spare parts allowance included in the initial price.
What are the shipping precautions for sensitive electronic sensors?
Sensors are sensitive to extreme temperatures and physical shock. Ensure the supplier uses anti-static packaging and shock-absorbent foam. If the meter includes a lithium battery, the supplier must provide a UN38.3 test report and MSDS to comply with international air freight regulations. For optical sensors, ensure they are stored in a moist environment (hydration bottle) during shipping to prevent the sensing element from drying out.
How can I verify the credibility of a Chinese manufacturer for scientific instruments?
Prioritize 'Audited Suppliers' on Made-in-China.com, as they have undergone third-party verification of their facilities. Request a video factory audit to see their calibration lab and QC testing area. A reliable manufacturer should be able to provide OEM/ODM customization and have a dedicated technical support team for troubleshooting via email or video call.