Dissolved oxygen meter
I have found results from10000+products and6000+suppliers aboutDissolved oxygen meter
RS485 Modbus Water Dissolved Oxygen Digital Do Meter
Benchtop Do Meter Digital Dissolved Oxygen Meter with Atc for Water Quality Testing
Benchtop pH, Conductivity and Dissolved Oxygen Meter Multi-Parameter Touch Screen
High-Quality Affordable Online Dissolved Oxygen Meter for Water Testing
Digital High Precision Water Quality Dissolved Oxygen Meter Sensor for Fish Pond
MDS-510DO Online Dissolved Oxygen Meter Support Salinity And Pressure Compensation
Low Cost Dissolved Oxygen Meter Do Sensor Water Measuring Device
Boqu Dog-2082s 4-20mA Output for Dissolved Oxygen Meters for Sale Do Meter
Bi-680 Industrial Portable Online Dissolved Oxygen Controller Meter
Handheld Portable Dissolved Oxygen Meter DO Meter
Modbus RTU Dissolved Oxygen Equipment Do Meter for Drinking Water
Do-C6539 Industrial Online Pure Water Micro Dissolved Oxygen Analyzer Meter
Optical Dissolved Oxygen Analyzer Online Water Dissolved Oxygen Meter Meter
Nobotech Do-6800yg Online Optical Dissolved Oxygen Meter Dissolved Oxygen Sensor 4~20mA Do Meter for Sewage
Yosemitech Y600-a&Y507-a Portable Dissolved Oxygen Meter
Portable Multiparameter pH ORP Conductivity TDS Salinity Dissolved Oxygen Meter Chloride Water Analyzer
Biobase E pH-210 Benchtop Automatic pH Meter Dissolved Oxygen Conductivity Meter for Laboratory
Bsk Professional Dissolved Oxygen Meter for Fish Pond Monitoring Professional Meter
Portable Dissolved Oxygen Meter for Accurate Field and Aquaculture Water Quality Testing
Conductivity Ec ORP Digital TDS Dissolved Oxygen Tester pH Meter
Online Do Meter Dissolved Oxygen Analyzer for Wastewater Treatment Monitoring
Aoda Do400f Benchtop Water Dissolved Oxygen Concentration Test Do Meter
High Quality pH/Dissolved Oxygen (DO) Meter Touch Screen
Measure Water Aquaculture Optical Online Dissolved Oxygen Meter
Sourcing guidance for Dissolved Oxygen Meter
How to choose the right sensor technology for a Dissolved Oxygen (DO) Meter?
Buyers must choose between Optical (Luminescence) and Electrochemical (Polarographic/Galvanic) sensors. Optical sensors are highly recommended for long-term stability and low maintenance as they do not require membrane replacement or electrolyte refills and are not affected by H2S interference. Electrochemical sensors are more cost-effective for occasional spot-checking but require regular calibration and a constant flow of water across the membrane to provide accurate readings.
What are the key technical specifications to verify for industrial or laboratory use?
Ensure the device features Automatic Temperature Compensation (ATC), as oxygen solubility varies significantly with temperature. For high-accuracy requirements, look for Salinity and Barometric Pressure Compensation. The measurement range should ideally cover 0 to 20 mg/L (or 0-200% saturation) with an accuracy of ±1% or ±0.1 mg/L. For field use, an IP67 waterproof rating is essential to prevent damage from accidental submersion.
Which compliance standards and certifications are necessary for international trade?
Suppliers should provide CE certification for the European market and FCC for the US. For environmental monitoring or laboratory applications, check for ISO 9001 manufacturing standards and compliance with EPA-approved methods (like ASTM D888-12). If the meter is used in hazardous environments (e.g., oil & gas), ATEX or IECEx explosion-proof certification is mandatory.
What are the typical usage scenarios and how do they affect product selection?
Aquaculture and Fish Farming require portable, rugged meters with long battery life for daily pond checks. Wastewater Treatment Plants prioritize online, continuous monitoring systems with 4-20mA or RS485 Modbus outputs for integration into PLC systems. Laboratory Research demands high-precision benchtop models with data logging capabilities and USB/Bluetooth connectivity for easy data export.
Cross-Border Procurement Considerations for DO Meters
What are the common risks when sourcing high-precision instruments from overseas?
The primary risk is sensor degradation during transit or receiving a unit with a depleted electrolyte/expired membrane. Always request calibration certificates dated within 6 months. To mitigate risks, use Made-in-China.com's Secured Trading services to ensure the product meets technical specifications before final payment is released.
How should I negotiate with suppliers regarding consumables and maintenance?
DO meters are 'razor-and-blade' products. Negotiate for a bundle that includes extra sensor caps, membranes, and electrolyte solutions (for electrochemical models). Ask for a guaranteed supply of replacement parts for at least 5 years to avoid equipment obsolescence. For bulk orders, request a 2-3% spare parts allowance included in the initial price.
What are the shipping precautions for sensitive electronic sensors?
Sensors are sensitive to extreme temperatures and physical shock. Ensure the supplier uses anti-static packaging and shock-absorbent foam. If the meter includes a lithium battery, the supplier must provide a UN38.3 test report and MSDS to comply with international air freight regulations. For optical sensors, ensure they are stored in a moist environment (hydration bottle) during shipping to prevent the sensing element from drying out.
How can I verify the credibility of a Chinese manufacturer for scientific instruments?
Prioritize 'Audited Suppliers' on Made-in-China.com, as they have undergone third-party verification of their facilities. Request a video factory audit to see their calibration lab and QC testing area. A reliable manufacturer should be able to provide OEM/ODM customization and have a dedicated technical support team for troubleshooting via email or video call.