Dissolved oxygen sensor
I have found results from10000+products and4000+suppliers aboutDissolved oxygen sensor
Dissolved Oxygen Sensor Water Quality Tester DO Electrode Built-in Salinity Compensation IP68 Probe
New Arrivals Fish Farming Opd700 IP68 High Quality Dissolved Oxygen Sensor with CE
Dissolved Oxygen Meter Intelligent Sensor Do Electrode High Precision Laboratory Analyzer Instrument
Durable M39*1.5 Thread Dissolved Oxygen Sensor with ABS Housing ±2%Fs Accuracy
Aoda Do-957-Q Polarographic Dissolved Oxygen Electrode Do Sensor with 4-Pin Aviation
Original Endress Hauser Oxymax Cos41 Liquid Analysis Dissolved Oxygen Sensor
Online Digital RS485 Modbus Water Quality Analyzer Dissolved Oxygen Detector Do Sensor
Output Probe Portable Water Dissolved Oxygen Electrode Sensor
Endress+Hauser/E+H Dissolved Oxygen Sensor Oxymax Cos61
IoT Portable Hydroponics Pool Use Opr Dissolved Oxygen Turbidity pH Ec Sensors Water Quality Tester
High Food Analysis Medical Research Precision Dissolved Oxygen Water Quality Testing Sensor Gwq-Do
Online Dissolved Oxygen Do Sensor Probe Digital Water Quality Do Monitoring Sensor
High Precision Electrochemical Polarographic Water Dissolved Oxygen Probe Electrode Sensor
Rk500-04 Optical Fluorescence RS485 0-20mg/L Dissolved Oxygen Sensor for Aquaculture
Precision Dissolved Oxygen Sensor with 0-20mg/L Range and High Accuracy
High Quality Digital Dissolved Oxygen Optical Do Sensor for Swimming Pool
Portable Optical Do Sensor Digital Dissolved Oxygen Meter for Aquaculture
Explosion Proof OEM Custom Dissolved Oxygen Sensor for Food Processing
Sourcing guidance for Dissolved Oxygen Sensor
What are the key technologies to consider when selecting a Dissolved Oxygen (DO) sensor for industrial use?
Buyers should primarily choose between Optical (Luminescence) and Electrochemical (Polarographic/Galvanic) technologies. Optical sensors are highly recommended for modern B2B applications because they do not require flow, are resistant to H2S poisoning, and have longer calibration intervals. Electrochemical sensors are more cost-effective for simple, continuous flow monitoring but require regular membrane replacement and electrolyte refilling.
Which technical specifications are critical for ensuring measurement accuracy in wastewater treatment or aquaculture?
Ensure the sensor features Automatic Temperature Compensation (ATC), as oxygen solubility varies significantly with temperature. For high-salinity environments like marine aquaculture, look for Salinity Compensation capabilities. The Response Time (T90) should ideally be less than 60 seconds for real-time process control, and the Measurement Range should cover at least 0-20 mg/L to handle supersaturation scenarios.
What compliance standards and protection ratings are necessary for outdoor or submerged installation?
The sensor housing must have an IP68 waterproof rating to withstand long-term immersion. For industrial integration, verify compliance with CE and RoHS standards. If the sensor is used in hazardous zones (e.g., chemical processing), ATEX or Ex-proof certification is mandatory. Additionally, ensure the output signal is compatible with standard controllers, typically RS485 (Modbus RTU) or 4-20mA analog signals.
How can a buyer evaluate the economic feasibility and Total Cost of Ownership (TCO)?
Beyond the initial purchase price, calculate the maintenance cycle costs. Optical sensors have a higher upfront cost but lower TCO due to the absence of membranes and chemicals. Evaluate the lifespan of the sensor cap (typically 1-2 years) and the availability of replacement parts. Sourcing from Made-in-China.com allows buyers to compare factory-direct prices, which can be 30-50% lower than European brands while maintaining similar precision levels.
Cross-Border Procurement Strategy for DO Sensors
What are the common risks when importing precision electronic sensors across borders?
The primary risks include calibration drift during transit and incompatibility with local voltage/PLCs. To mitigate this, request factory calibration certificates and ensure the supplier uses anti-static, shock-proof packaging. Always confirm the HS Code (typically 9027.90) to accurately calculate import duties and avoid customs delays.
How should I negotiate with Chinese suppliers to ensure quality and long-term support?
Focus on Warranty Terms (minimum 12 months) and Technical Support. Ask if they provide English-language SDKs or configuration software. For bulk orders, negotiate a 2-5% spare parts allowance (e.g., extra sensor caps or O-rings). Use the Secured Trading services on Made-in-China.com to ensure payment is only released upon verification of shipping documents.
What is the best shipping method for sensitive analytical instruments to ensure safety and speed?
For high-value sensors, Air Express (DHL/FedEx/UPS) is preferred over sea freight to minimize exposure to humidity and extreme temperature fluctuations in containers. Ensure the commercial invoice clearly states 'Electronic Sensor for Water Analysis' to facilitate smooth customs clearance under scientific instrument categories.





























