SourcingAI

Explosion proof dehumidifier

I have found results from2000+products and700+suppliers aboutExplosion proof dehumidifier

Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: General
Type: Cooling
Cabinet Air Conditioner
Type: Multifunction
Type: Refrigerative Dehumidifier
Type: Desiccant Dehumidifier
Certification: CE
Fan: With Fan
Dehumidification Capacity: 10-20Kg/H
Control: Automatic
5-38 Degrees Celsius
Structure: Split
Air Tube Material: Galvanized Sheet
Corrosion Durability: Higher
Noise Level: Ultra Low
Lifetime: >20 years
Condition: New
Operating Voltage: 380/400 VAC
Application Fields: Mechanical Engineering
Mounting: Floor Standing
Usage: Car
With Timing Function
Washable Air Filter
Certification: RoHS
Certification: ISO
Certification: CCC
Certification: CQC
Certification: GS
Certification: EMC
Certification: CB
Dehumidification Capacity: 30-40Kg/H
Dehumidification Capacity: <10Kg/H
Dehumidification Capacity: 20-30Kg/H
Structure: Integral
Structure: Overall Mobile
Air Tube Material: FRP
Corrosion Durability: Ultrahigh
Noise Level: Low
Lifetime: 15~20 years
Usage: Industry
Usage: Home
Without Timing Function
External Drain Connect
Function: LED Display
Bucket Full Indicator Light
Removable Water Tank
Function: Automatic Defrost
Automatic Humidistat Control
Function: Auto Restart
Function: Adjustable Humidistat

Sourcing guidance for Explosion Proof Dehumidifier

What are the critical technical specifications for selecting an explosion-proof dehumidifier?

When sourcing these units, you must prioritize the Explosion-Proof Grade (e.g., Ex d IIB T4 or Ex d IIC T4) to ensure it matches the hazardous zone classification (Zone 1 or Zone 2). Key components like the compressor, fan motor, and control box must be hermetically sealed or housed in flameproof enclosures. Additionally, verify the dehumidification capacity (measured in Liters per Day) against your room volume and the operating temperature range, as hazardous environments often involve extreme thermal conditions.

Which international compliance standards are mandatory for these products?

For global trade, the product must carry ATEX (Europe) or IECEx (International) certification. If you are importing into China, CNEx is required. Ensure the supplier provides a Certificate of Conformity that matches the specific model number. For electrical safety, look for ISO 9001 manufacturing standards and IP65 or higher ingress protection ratings to prevent dust and moisture from compromising the internal explosion-proof circuits.

How does the cooling method affect the suitability for hazardous environments?

Most industrial units use air-cooled condensers, but in highly volatile environments, water-cooled systems may be preferred to minimize surface temperature. Ensure the unit features anti-static fan blades and spark-proof wiring. The heat exchanger should be treated with anti-corrosion coatings (like epoxy resin) if the dehumidifier is used in chemical plants or offshore platforms where corrosive gases are present.

What are the typical usage scenarios for explosion-proof dehumidifiers?

These units are essential for petrochemical plants, pharmaceutical cleanrooms, ammunition depots, and hydrogen storage facilities. They prevent moisture-induced corrosion of sensitive equipment and, more importantly, control humidity to prevent static electricity discharge, which could ignite volatile gases or dust in the atmosphere.

Cross-Border Procurement & Risk Management

How can I verify the authenticity of explosion-proof certifications from a distance?

Request the unique certificate number and verify it directly on the IECEx or ATEX official databases. On Made-in-China.com, prioritize Audited Suppliers whose facilities have been inspected by third parties like SGS or Bureau Veritas. Always ask for a video demonstration of the unit's nameplate and the corresponding certification marks to ensure the physical product matches the paperwork.

What are the specific shipping precautions for industrial dehumidifiers?

Dehumidifiers contain refrigerants, which are classified as Class 2.2 Non-flammable gas or higher under IMDG codes. You must confirm if the unit is shipped pre-charged or empty. If pre-charged, it requires Dangerous Goods (DG) packaging and specific declarations. Ensure the supplier uses wooden crate packaging with shock-absorption bases to prevent compressor displacement during sea freight.

What negotiation strategies should be used with specialized equipment suppliers?

Focus on Long-term Technical Support rather than just the unit price. Negotiate for a spare parts kit (e.g., sensors, seals, and filters) to be included in the initial FOB price. Given the high value, suggest a staged payment structure: 30% deposit, 60% after successful Factory Acceptance Testing (FAT) verified via video, and 10% after receipt and inspection.

How do I ensure transaction security for high-value industrial orders?

Utilize Secured Trading Services provided by Made-in-China.com to protect your payment until shipping documents are uploaded. For explosion-proof equipment, it is highly recommended to hire a third-party inspector to perform a Pre-Shipment Inspection (PSI) specifically checking the integrity of the explosion-proof seals and cable glands.

Related queries