Fluorescence microscope
I have found results from4000+products and1000+suppliers aboutFluorescence microscope
Xsz-N117aiii School Research Optical Fluorescence Biological Microscopes Trinocular Microscope
Biobase Fluorescence Biological Viewing Head Adjustable LED Trinocular Stereo Microscope
Olympus Bx63 Auto Professional Fluorescence Biological Microscope
Boshida Bd-Ne610 Phase Contrast Dark Field Fluorescence Microscope for Medical Research
Boshida Bd-Nib910 Apo Objective Fluorescence Dic Phase Contrast Inverted Biological Microscope
LED Binocular Fluorescence Microscope Infinite Plan Microscope (BM-2000IFB)
Binocular Fluorescence Microscope for Routine Applications (LF-202)
Source Price Fluorescence Biological Microscope Double Layers Mechanical Stage
Olympus BX53 Motorized Automatic Biological Semi-Motorized Fluorescence Microscope
Trinocular Inverted Optical Laboratory Fluorescence Microscope for Biology Reasearch
Bds400-FL Professional Laboratory 40X~400X Magnification Inverted Fluorescence Microscope
Kohler Illumination 100W Mercury Lamp Inverted Blue Green Color Filter Fluorescence Microscope
Laboratory Instrument Binocular Rotatable Bk6000-FL Binocular Fluorescence Microscope
Olympus Cx43 Binocular Triocular Contrast Fluorescence Video Biological Microscope
Professional High Quality Epi-Fluorescence Microscope EFM-3201
Optical Inverted Research Lab Fluorescence Microscope Xif100
Fluorescence Microscope with Transmitted Illumination Halogen Lamp 6V/30W
China Epi-Fluorescence Attachment Inverted Biological Microscope Bds400-FL2
Inverted Phase Contrast Fluorescence Microscope for Enhanced Imaging
Omega 7 Articulating Arm Microscope for Enhanced Medical Fluorescence Imaging
Trinocular Biological Fluorescence Microscope with Digital Camera
Sourcing guidance for Fluorescence Microscope
What are the key technical specifications to consider when selecting a fluorescence microscope for professional use?
When sourcing a fluorescence microscope, you must prioritize the Light Source, Optical System, and Filter Cubes. For the light source, Mercury Vapor lamps offer high intensity but have a shorter lifespan, whereas LED Fluorescence illumination is becoming the industry standard due to its 50,000-hour lifespan, instant on/off capability, and reduced heat generation. Ensure the optical system uses Infinity Color Corrected Optics (ICS) to prevent aberrations. Additionally, verify that the Numerical Aperture (NA) of the objectives is high (e.g., Plan Apochromatic lenses), as fluorescence brightness is proportional to the fourth power of the NA.
How do I ensure the microscope meets international compliance and safety standards?
For medical and laboratory equipment, compliance is non-negotiable. Ensure the supplier provides CE marking for the European market and FDA registration if intended for the US. Specifically for fluorescence units, look for IEC 61010-1 safety requirements for electrical equipment. If the unit uses a Mercury lamp, it must comply with RoHS (Restriction of Hazardous Substances) directives regarding bulb disposal and housing safety to prevent UV radiation leakage.
What are the functional requirements for different usage scenarios like clinical vs. research applications?
For clinical diagnostics (e.g., TB or malaria screening), a basic upright microscope with a stable LED blue light filter is often sufficient. However, for advanced life science research involving live cell imaging, an Inverted Fluorescence Microscope is required to accommodate bulky culture vessels. You should also check for Phase Contrast or DIC (Differential Interference Contrast) compatibility to allow for simultaneous observation of unstained structures alongside fluorescent markers.
How can I evaluate the economic feasibility and long-term value of the purchase?
Calculate the Total Cost of Ownership (TCO) by factoring in the cost of replacement bulbs and specialized filters. While LED-based systems have a higher upfront cost, they eliminate the need for frequent bulb replacements and external power supplies, leading to a 30-40% reduction in maintenance costs over five years. Always request a modular design that allows for future upgrades of filter cubes or digital camera attachments to extend the equipment's lifecycle.
Cross-Border Procurement Strategy & Risk Management
What are the primary risks when importing high-precision optical instruments like microscopes?
The greatest risks are physical damage during transit and calibration misalignment. Optical components are extremely sensitive to vibration. You must mandate double-layered shockproof packaging with foam inserts and ensure the shipment is marked as 'Fragile: High-Precision Instrument'. It is highly recommended to use third-party inspection services (like those offered via Made-in-China.com) to verify the alignment and light intensity before the balance payment is made.
How should I negotiate with suppliers to ensure transaction security and quality assurance?
Utilize Trade Assurance or secure payment terms to protect your capital. When negotiating, demand a minimum 2-year warranty on the optical path and a 1-year warranty on electronic components. Ask the supplier to provide a Factory Acceptance Test (FAT) report including images of the fluorescence excitation spectrum. For bulk orders, negotiate for 2-5% spare parts (such as fuses, dust covers, or extra objective cases) to be included at no extra cost.
What are the logistics and customs considerations for shipping to international markets?
Microscopes are classified under HS Code 9011. Ensure your supplier provides a detailed Commercial Invoice, Packing List, and Certificate of Origin. Because these are high-value items, choose Air Freight over Sea Freight to minimize the duration of exposure to humidity and mechanical shock. Ensure the wooden crates used for shipping are IPPC fumigated to avoid customs delays and potential fines at the destination port.





























