SourcingAI

Gold purity tester

I have found results from1000+products and300+suppliers aboutGold purity tester

Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Computer Multi Element Analyzer
Application: Metal
Frequency: 50±1HZ
Performance: Semi-automatic
Function: Storage
Customized: Customized
Display: Computer Screen
Weight: 0-100Kg
Power Source: AC220V±22V
Warranty: > 1Year
Detection Method: Spectrophotometer
Advantage: High Resolution
Principle: Classic Spectrometer
Wavelengths: Infrared Spectrometer
Dispersive Element: Interferometer Spectrometer
Light Number: Monochromator
Certification: ISO9001
Analysis: Infrared Analysis
Accuracy Grade: 1
Load Way: Electronic Load
Loading Method: Dynamic Load
Control: Computer Control
Accuracy: ± 5%
Maximum Measurement Range: ≤3D
Reflection Density Meter
Viscometer Type: Rotary
Test Density: Heavy
Viscometer Reproducibility: ±0.2%
Viscometer Rotor Number: 4
Viscometer Rotor Speed: 6r/min
Viscometer Rotor Specifications: 1 Size
Element: Metals Analyzer
Application: Laboratory Apparatus
Performance: Automation
Customized: Non-Customized
Display: Digital
Power Source: AC220V
Warranty: 1 Year
Detection Method: Spectrograph
Advantage: High Sensitive
Principle: New Spectrometer
Dispersive Element: Grating Spectrometer
Certification: CE
Certification: RoHS
Control: Manual Control

Sourcing guidance for Gold Purity Tester

What are the primary technologies used in gold purity testers and how do I choose between them?

There are three main technologies: X-Ray Fluorescence (XRF), Ultrasonic testing, and Electronic/Conductivity testing. XRF analyzers are the industry standard for non-destructive, high-precision analysis, providing a full elemental breakdown (e.g., gold, silver, copper, zinc). Ultrasonic testers are best for detecting 'salted' gold (tungsten cores) in large bars. Electronic testers (like the Mizar or AuRACLE) are portable and cost-effective for quick retail checks but may require calibration and only provide a karat range rather than a percentage.

What technical specifications should a B2B buyer prioritize for high-accuracy requirements?

Buyers should look for a Detection Limit of 0.01% to 0.1% and a Measurement Precision of ±0.01% to ±0.1%. For XRF devices, ensure the unit uses a Silicon Drift Detector (SDD) rather than a Proportional Counter for superior resolution. Additionally, verify the Excitation Source (X-ray tube) voltage; a 50kV/200µA rating is typically required for penetrating thicker jewelry or coins.

What compliance standards and certifications are mandatory for importing these devices?

Since XRF testers emit ionizing radiation, they must comply with Radiation Safety Standards (such as FDA 21 CFR 1020.40 in the US or CE/RoHS in the EU). Ensure the supplier provides a Radiation Leakage Report showing levels below <1.0 μSv/h. For laboratory-grade equipment, ISO 9001 for manufacturing and IEC 61010-1 for electrical safety are essential.

How does the Archimedes Principle (Hydrostatic) method compare to electronic testing?

The Archimedes Principle (Density Method) is highly reliable for solid gold items without stones or hollow centers. It is economically feasible as it requires only a high-precision balance and water. However, it cannot distinguish between gold and materials with similar density (like tungsten). For professional sourcing, a combination of Density Testing and XRF is recommended to ensure 100% authenticity.

Cross-Border Procurement & Risk Management for Precision Instruments

What are the common risks when purchasing high-value testing equipment from overseas?

The primary risks include damage during transit affecting calibration and non-compliance with local radiation regulations. To mitigate this, insist on Double-Layered Shockproof Packaging and request a Pre-Shipment Inspection (PSI). Ensure the supplier is verified on Made-in-China.com to utilize trade security services that protect your payment until the goods are verified.

How should I negotiate with suppliers regarding after-sales support for technical instruments?

Negotiate for a minimum 2-year warranty and clarify the Remote Technical Support protocol. Since shipping a 30kg XRF machine back for repair is costly, prioritize suppliers who offer modular replacement parts and provide video calibration tutorials. Ask for a guaranteed response time of under 24 hours for technical troubleshooting.

What are the logistics and customs considerations for shipping gold testers to international markets?

Gold testers containing X-ray tubes may be classified as Class 9 Dangerous Goods or restricted items in some jurisdictions. Use incoterms like DAP or DDP if you want the supplier to handle complex customs clearances. Ensure the HS Code (typically 9027.80) is correctly declared to avoid delays. For shipping to the US or Europe, ensure the Radiation Safety Filing is included in the shipping documents to prevent seizure at customs.

How can I verify the credibility of a supplier on Made-in-China.com?

Look for the 'Audited Supplier' badge, which indicates the factory has been physically inspected by third-party agencies like SGS or Bureau Veritas. Check their Export Experience—suppliers with over 5 years of experience in precision optics or electronics are generally more reliable. Review their Transaction History to ensure they have successfully shipped to your specific region previously.

Related queries