Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Current Transformer
Type: Variable Inductor
Type: Choke Inductor
Application: Power
Phase: Single
Core: Core-type Transformer
Cooling Method: Dry-type Transformer
Winding Type: Multi-winding Transformer
Certification: ISO9001
Usage: Single-phase Transformer
Frequency Characteristics: High Frequency
Operation Condition: Indoor
Multilayer Honeycomb Type
Common Insulating Materials
Installation: Active Type
Magnetic Circuit Structure: Combined Type
Voltage Transformation Principle: Electromagnetic Type
Structure: Mutual Inductor
Working Frequency: High Frequency
Range of Application: Power Measurement
Packaging Form: Power Coils
Structure of Winding: Multilayer Coil
Nature of Operation: Choke Coil
Structure of Magnetizer: Ferrite Coil
Inductor Value: Fixed Inductor
Shape of Core: Ring
Application: Electronic
Application: Instrument
Application: Lighting
Application: Rectifier
Application: Audio
Phase: Three
Oil-immersed Type Transformer
Winding Type: Two-winding Transformer
Certification: ISO9001-2000
Certification: CCC
Certification: UL
Usage: Rectifier Transformer
Usage: Power Transformer
Usage: Protection
Usage: Measurement
Usage: Distribution Transformer
Usage: Combined Transformer
Frequency Characteristics: Power Frequency
Structure: Inductive Choke
Range of Application: Choke
Packaging Form: Chip Inductance

Sourcing guidance for High Voltage Ferrite Transformer

What are the key technical specifications to consider when sourcing High Voltage Ferrite Transformers?

Buyers must prioritize magnetic core material (e.g., MnZn vs. NiZn), as this determines the operating frequency and power loss. Key specs include Input/Output Voltage Ratios, Isolation Voltage (typically 2.5kV to 10kV+), and Operating Frequency (20kHz to 500kHz). Ensure the Creepage Distance and Clearance meet safety standards to prevent electrical arcing in high-altitude or high-humidity environments.

Which international compliance standards are mandatory for these components?

For global market access, transformers must adhere to UL 60950/62368 (Information Technology Equipment) or IEC 60601 (Medical Grade). Ensure the supplier provides RoHS and REACH certifications to confirm the absence of hazardous substances. For the European market, a CE Marking and compliance with the Low Voltage Directive (LVD) are essential.

How does the choice of ferrite core shape affect performance in B2B applications?

The core geometry—such as EE, EER, ETD, or PQ types—impacts heat dissipation and EMI shielding. ETD cores are ideal for high-power applications due to their excellent cooling, while PQ cores offer better space utilization and Electromagnetic Interference (EMI) shielding, which is critical for sensitive medical or telecommunications equipment.

What quality control measures should be requested from the manufacturer?

Demand a 100% Hi-Pot (High Potential) Test report to verify insulation integrity. Additionally, request Partial Discharge (PD) testing for ultra-high voltage units to ensure long-term reliability. Suppliers should also provide Inductance Tolerance reports (typically ±10% or ±20%) and Temperature Rise data under full load conditions.

Cross-Border Procurement & Risk Management for Electronic Components

How can I mitigate the risk of receiving counterfeit or sub-standard ferrite cores?

Always verify the brand of the raw ferrite material (e.g., TDK, Magnetics, or reputable domestic brands like TDG). Request a Material Safety Data Sheet (MSDS) and a Certificate of Analysis (COA) for each batch. Using Made-in-China.com’s Secured Trading services can provide an extra layer of protection by ensuring payment is only released after quality verification.

What are the best strategies for negotiating with transformer manufacturers?

Focus on Total Cost of Ownership (TCO) rather than just the unit price. Negotiate based on Volume Tiers (e.g., 1k, 5k, 10k units) and ask for Custom Tooling Fee waivers for long-term contracts. Discuss Lead Time Guarantees, as customized windings can take 4–6 weeks; securing a Safety Stock Agreement can prevent supply chain disruptions.

What shipping precautions are necessary for fragile ferrite components?

Ferrite is a brittle ceramic material prone to cracking. Ensure the supplier uses Vacuum Packaging or Custom EPE Foam Trays to prevent movement. Specify Palletization with Corner Protectors for bulk sea freight. For air express, ensure the cartons are Double-Walled and marked with 'Fragile' and 'Keep Dry' symbols to avoid moisture-induced insulation failure.

How do I ensure transaction security when dealing with overseas suppliers?

Conduct due diligence by checking the supplier's Audit Reports and Business License on Made-in-China.com. Use Escrow-based payment methods and avoid direct wire transfers to unknown personal accounts. For large orders, consider hiring a Third-Party Inspection Agency (like SGS or Intertek) to perform a pre-shipment inspection (PSI) at the factory.

Related queries