SourcingAI

Hv-relay-50kv

I have found results from200+products and80+suppliers aboutHv-relay-50kv

Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Universal Testing Machine
Type: Circuit Breaker
Display: Digital
Control: Computer Control
Weight: 0-100Kg
Power Source: AC220V
High Voltage Circuit Breakers
Operation: Manual Type
High-Speed Circuit Breaker
Arc-extinguishing Medium: SF6
Installation: Fixed
Structure: ACB
Poles Number: 3
Conventional Circuit Breaker
Certification: ISO9001-2000
Max Diameter of Workpiece: <500mm
Maxcapacity: <1000KN
Accuracy Grade: 1
Load Way: Electronic Load
Connectors: USB
Test Mode: Instant Test
Digital Cable Tester
Test Region: Forming Cable
Power: Electricity
Customized: Customized
Color: Red
Mass Scope of Workpiece: <900kg
Loading Method: Static Load
Electrical & Electronics
Phase: Single
Core: Shell-type Transformer
Cooling Method: Dry-type Transformer
Winding Type: Auto-transformer
Frequency Characteristics: Power Frequency
Shape of Core: OD
Condition: New
Control: Manual Control
Weight: 100-500Kg
Power Source: AC380V
Circuit-Breaker Failure Protection
Function: Overcurrent Protection
Function: OVP(Overvoltage Protection)
Function: RCCB
Function: Measurement
Certification: CCC
Certification: CE
Certification: RoHS
Certification: ISO9001
Certification: ISO: 9001
Accuracy Grade: 0.5
Usage: Single-phase Transformer
Loading Method: Dynamic Load
Application: Instrument
Application: Power
Application: Electronic
Core: Core-type Transformer
Oil-immersed Type Transformer

Sourcing guidance for HV-Relay-50KV

What are the key technical specifications to prioritize when sourcing a 50KV High Voltage Relay?

When dealing with ultra-high voltage components like a 50KV relay, the most critical factor is Dielectric Strength. You must ensure the insulation resistance is typically >10^12 ohms to prevent arcing. Additionally, verify the Contact Resistance (usually <50mΩ) to minimize heat generation. For vacuum or gas-filled relays, check the leakage rate specifications to ensure long-term vacuum integrity, which is vital for maintaining the 50KV breakdown voltage rating.

Which international compliance standards are mandatory for 50KV HV Relays?

Safety is paramount at 50KV. Ensure the supplier complies with IEC 60664-1 (Insulation coordination for equipment) and IEC 60255 (Measuring relays and protection equipment). For the North American market, UL certification for high-voltage components is highly recommended. Furthermore, ensure the product meets RoHS and REACH standards to guarantee the absence of hazardous substances in the insulation materials.

How do usage scenarios affect the selection of a 50KV relay?

The choice depends heavily on the application. For Medical Imaging (MRI/X-Ray), you need high reliability and low noise. For Test and Measurement equipment, look for low parasitic capacitance to maintain signal integrity. If the relay is for Industrial Power Supplies or Lasers, prioritize high carry current capacity and thermal dissipation features. Always confirm if the relay is designed for 'Hot Switching' or 'Cold Switching', as switching under load at 50KV will significantly reduce contact life.

What are the maintenance and longevity expectations for these components?

High voltage relays are often rated by Mechanical Life (e.g., 1 million cycles) and Electrical Life (e.g., 100,000 cycles at rated load). For a 50KV component, environmental sealing (IP67 or hermetic sealing) is crucial to prevent dust and moisture from creating conductive paths. Ask the supplier for MTBF (Mean Time Between Failures) data to evaluate the economic feasibility of long-term integration.

Cross-Border Procurement Risks and Strategies for High-Voltage Components

How can I mitigate the risk of receiving sub-standard high-voltage components?

Request a Factory Acceptance Test (FAT) report specifically showing a High-Pot (High Potential) test at or above 50KV for each unit. For large orders, hire a third-party inspector via Made-in-China.com to verify the insulation testing equipment used by the manufacturer is calibrated to international standards.

What are the logistics precautions for shipping 50KV vacuum relays?

Vacuum relays are fragile and sensitive to vibration. Ensure the supplier uses anti-static, shock-absorbent foam packaging and marks the crates as 'Fragile: High-Precision Electronic Instrument'. For international shipping, use DAP or CIF terms with comprehensive insurance to cover potential internal damage that may not be visible externally upon arrival.

How should I negotiate with suppliers regarding customization and technical support?

Since 50KV relays often require specific mounting or lead wire lengths, negotiate for customized cable terminations (e.g., silicone high-voltage wires). Demand a technical agreement as part of the contract that includes 24-hour technical response times and a clear warranty policy (minimum 12-24 months) for dielectric failure.

What transaction security measures should be taken for high-value B2B orders?

Use Secured Trading services on Made-in-China.com to ensure payment is only released after the shipping documents are verified. For first-time orders, utilize a 30% deposit and 70% balance payment structure after providing a third-party quality inspection certificate.

Related queries