SourcingAI

Hydrophobic membrane filter

I have found results from8000+products and2000+suppliers aboutHydrophobic membrane filter

Commonly Used:
US$
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Surgical Supplies Materials
Type: PP Filter
Folding Microporous Filter
Type: Air Filter
Customized: Customized
Standard Component: Non-Standard Component
Category: Air Filter
Material: Plastic
Ethylene Oxide Sterilization
Group: Adult
With Logo Printing
Disposable: Disposable
Certification: CE
Reactant State: Liquid
Outer Diameter: 13mm
Pore Size: 0.22um
Media Material: PES
Feature: Compatible
Application: Industry
Filtration Grade: PRE Filter
Activated Carbon Filter Type: Compact
Power Source: Manual
Filter Connector: Flat Connector
Usage: Liquid Filter
Cartridge Installation: Vertical Lifting
Motive Force: Pressure
Style: Vertical
Performance: Efficient Filtration
Filter Bag Environment: High-Temperature
Rubber / Plastic
Material: PTFE
Certification: ISO
Certification: RoHS
Certification: UR
Outer Diameter: 33mm
Media Material: PTFE
Media Material: PVDF
Food and Beverage
Application: Medicine
Application: Textile
Application: Metallurgy
Filtration Grade: Medium Filter
Filtration Grade: HEPA Filter
Activated Carbon Filter Type: Bulk Type
Filter Connector: 226 Connector
Usage: Air Filter
Usage: Environmental Protection
Usage: Chemical Industry

Sourcing guidance for Hydrophobic Membrane Filter

What are the key technical specifications to consider when selecting a hydrophobic membrane filter?

When sourcing hydrophobic membrane filters, you must prioritize pore size (typically 0.1μm to 5.0μm) and material compatibility. Common materials include PTFE (Polytetrafluoroethylene), which offers the highest chemical resistance, and PVDF (Polyvinylidene Fluoride). Ensure the Water Entry Pressure (WEP) is high enough to prevent liquid penetration in venting applications, and verify the Air Flow Rate to ensure it meets your system's throughput requirements.

Which compliance standards are essential for medical and laboratory-grade filters?

For medical or pharmaceutical use, filters must meet USP Class VI Plastics tests for biocompatibility. If the product is intended for the US market, FDA 21 CFR 177 compliance for food and drug contact is mandatory. For European markets, ensure the supplier adheres to REACH and RoHS regulations. Additionally, look for ISO 13485 certification if the filters are components for medical devices.

How do usage scenarios dictate the choice of membrane support material?

Hydrophobic membranes are often fragile and require a support layer (backing) like Polyester (PET) or Polypropylene (PP). For high-temperature sterilization (autoclaving), PET is preferred due to its thermal stability. For chemical filtration, a pure PTFE membrane without backing or with a chemically inert support is necessary to avoid degradation and extractable contamination.

What performance benchmarks ensure long-term reliability in industrial venting?

Reliability is measured by Bubble Point testing to ensure membrane integrity and bacterial retention efficiency (BRE), which should be >99.99% for sterile venting. For outdoor sensors or automotive components, check the IP Rating (e.g., IP67 or IP68) to guarantee protection against dust and water immersion while maintaining gas permeability.

Cross-Border Procurement & Risk Management for Membrane Filters

What are the primary risks when sourcing technical membranes from overseas suppliers?

The biggest risk is batch-to-batch inconsistency, which can lead to system failures. To mitigate this, require a Certificate of Analysis (COA) for every shipment. Another risk is counterfeit materials; ensure the supplier is a verified manufacturer on Made-in-China.com and request scanning electron microscopy (SEM) images of the membrane structure to verify pore uniformity.

How should I negotiate quality assurance and return policies with international suppliers?

Negotiate a Quality Agreement that defines 'defective' based on specific metrics like flow rate deviation (>15%) or integrity test failure. Use Trade Assurance services to secure your payment. For high-value bulk orders, insist on a pre-shipment inspection (PSI) by a third party like SGS or Intertek to verify specifications before the balance payment is made.

What logistics and storage precautions are necessary for hydrophobic membranes?

Membranes are sensitive to electrostatic discharge (ESD) and environmental contaminants. Ensure the supplier uses double-layer anti-static packaging and vacuum sealing. During shipping, avoid high-pressure environments that could compromise the microporous structure. Upon arrival, store them in a controlled cleanroom environment with stable temperature and humidity to prevent premature aging of the polymer.

How do international trade policies affect the importation of filtration technology?

Check the HS Code (typically 5911.90 or 8421.99) to determine applicable import duties. Be aware of Export Control Lists if the membranes have 'dual-use' applications (industrial vs. military). Always clarify Incoterms (e.g., DAP or CIF) to understand where the risk transfers, especially since specialized filters can be easily damaged during customs inspections if not handled properly.

Related queries