Ignition transformer
I have found results from10000+products and3000+suppliers aboutIgnition transformer
Startnow High Voltage Transformer Flyback Ignition Coil for 30W 40W 45W 50W CO2 Laser Power Supply
ETD Type Mini Electronic Ignition Fly-Back Transformer
Cofi High Voltage Burner Ignition Transformer for Industrial Gas Burner Tre820
Kromschroeder Ignition Transformer High-Voltage Package Tzi7.5-12/100W
Kromschroeder Tgi7.5-12/100W Ignition Transformer High-Voltage Package
Lcecip G10m16-Zc Burner Fuel Burning Machine Ignition Transformer
Yhdc TIF-031 PCB Welding Type High Frequency Ignition Transformer with Turn Ratios 1/256
Powerful Class2 HVAC 24V Transformer for Demanding Ignition and Staging Control Systems
Ignition Transformer Type Ebi4 1p High Voltage Burner Igniter for Industrial
Kromschroder Tzi 7, 5-12/100W High Voltage Burner Igniter for Industrial Gas Ignition Transformer
Kromschroder Ignition Transformer Tzi 7, 5-20/33W High Voltage Burner Igniter for Industrial
Wholesale Price Original Gongan Ignition Transformer F06-SA6 for Industrial Combustion Heating
Sourcing guidance for Ignition Transformer
What are the key technical specifications to consider when selecting an ignition transformer?
When sourcing ignition transformers, you must prioritize Input Voltage (typically 110V, 220V, or 230V) and Output Voltage (ranging from 5kV to 15kV) to ensure compatibility with your burner system. Pay close attention to the Duty Cycle (ED%), as intermittent duty models (e.g., 19% or 33% over 3 minutes) will overheat if used for continuous ignition. Additionally, verify the Secondary Current (mA) and Spark Gap distance capabilities to ensure a stable arc for the specific fuel type (gas or oil) being used.
How do I ensure the ignition transformer meets international safety and compliance standards?
Compliance is critical for high-voltage components. Ensure the supplier provides CE marking for the European market or UL/CSA certification for North America. For industrial boiler applications, look for adherence to EN 298 (for automatic gas burner control systems) and IP ratings (e.g., IP40 or IP54) to guarantee protection against dust and moisture ingress in harsh boiler room environments.
What are the differences between electronic and conventional inductive ignition transformers?
Electronic ignition transformers are generally lighter, more compact, and offer a higher spark frequency, making them ideal for modern, space-constrained burners. Conventional inductive (iron-core) transformers are heavier but often more robust against voltage fluctuations and have a proven track record for longevity in heavy industrial settings. Your choice should depend on the available installation space and the stability of the local power grid.
What usage scenarios and fuel types require specific transformer features?
For oil-fired burners, a higher output energy is often required to atomize and ignite the fuel compared to gas. If the application involves high-altitude environments, you must account for dielectric strength reduction, which may require a transformer with higher insulation ratings. For outdoor or marine applications, ensure the casing is made of corrosion-resistant materials or high-grade epoxy resin encapsulation.
Cross-Border Procurement Risks and Strategies for Ignition Transformers
How can I mitigate the risk of receiving defective high-voltage components?
Request a pre-shipment inspection (PSI) that includes a high-potency (Hi-Pot) test and a functional spark test. Since these are sensitive electrical components, ensure the supplier uses anti-static packaging and shock-absorbent materials to prevent internal coil damage during international transit. Using a reputable platform like Made-in-China.com allows you to select Audited Suppliers who have undergone third-party verification of their manufacturing capabilities.
What are the best practices for negotiating with ignition transformer manufacturers?
Focus on Total Cost of Ownership (TCO) rather than just the unit price. Negotiate for a longer warranty period (at least 18-24 months) to offset the risk of premature failure. If purchasing in bulk, request tiered pricing based on annual volume commitments, and ask for customized cable lengths or connector types to be included in the base price to reduce your assembly labor costs.
What should I consider regarding international shipping and customs for this product?
Ignition transformers contain copper windings and magnetic cores, making them heavy; therefore, Sea Freight is most economical for bulk orders, while Air Express should be reserved for urgent replacements. Ensure the HS Code (typically 850431) is correctly declared to avoid customs delays. Be aware of import duties on electrical machinery specific to your country and ensure all Technical Data Sheets are included in the shipping documentation for smooth clearance.
How do I ensure transaction security when dealing with overseas suppliers?
Always use secure payment methods such as Letters of Credit (L/C) for large volumes or Escrow-based payment services provided by professional B2B platforms. Avoid direct wire transfers to unknown accounts. On Made-in-China.com, look for the Secured Trading Service to protect your payment until the goods are confirmed to meet your specified technical requirements.





























