Incubator shaker
I have found results from7000+products and2000+suppliers aboutIncubator shaker
Laboratory Oscillating Incubator, Constant Temperature Shaker for Precision Culture Preparation
Precise Temperature Control Shaker Lab Equipment Oscillator Shaking Incubator Orbital Shaker
SCITEK Shaking Incubator Forced Convection Constant Temperature Incubation Shaker
Laboratory Equipment Thermo Shaker Incubator, Thermal Mixer (TS100)
Lab Shaker for Microplates / Microplate Incubator & Shaker (TS200)
Advanced Thermo Shaker Incubator for Precision Laboratory Mixing
Double-Layer Bottle Shaker Lab Equipment Medical Shaker Incubator Flask Orbital Shaker
Mecanmed One Stop Medical Solution Laboratory Shakers Three-Layer Stackable Illuminated Incubator Shaker
Orbit Lab Shaker Incubator Electrical 50~300rpm 10mm
LCD Display Constant Temperature Shaking Incubator, Constant Temperature Shaker with CE ISO
Nanbei Instruments Laboratory Orbital Incubator Shaker Lab Equipments
Nanbei Instruments Micro-Processor Incubator Shaker with Low Temperature Function
Nanbei Instruments Orbital Bottle Cell Culture Shaking Plate Mixer Lab Incubator Shaker
Laboratory Shaker Shaking Incubator Constant Temperature Shaker
Small Capacity Thermostatic Shaking Incubator Constant Temp Shaker
Laboratory Shaking Incubator Table-Top Labor Shaker
Biobase Elisa Microplate Shaking Incubator Thermostatic Shaker for Lab
Laboratory Shaker Shaking Incubator Shaker Incubator
Water Bath Shaker Shaking Incubator Incubator Orbital Shaker
Temperature Control Equipment Orbital Shaker Shaking Incubator
Aoda Aos30 Microorganism Incubation and Cultivation Orbital Incubator Shaker
Horizontal Laboratory Incubator Shaker Superimposed Constant Temperature Shaker
Laboao 245L Horizontal Refrigerated Rotary Oscillation Thermo Incubator Shaker
Laboao Single Layer Stackable Reciprocating Thermo Incubator Shaker
Laboao Double Layer Rotary Orbital Oscillation Thermo Incubator Shaker
Sourcing guidance for Incubator Shaker
What are the key technical specifications to consider when selecting an incubator shaker for laboratory use?
Buyers must prioritize temperature range and stability, typically requiring a range from ambient -15°C to 60°C with an accuracy of ±0.1°C. The shaking speed (RPM) should be adjustable, usually between 30-500 RPM, with a triple-eccentric drive mechanism to ensure uniform motion and long-term stability. Additionally, check for CO2 concentration control (if for cell culture) and humidity sensors to prevent sample evaporation.
How do I ensure the equipment meets international safety and quality standards?
Verify that the supplier holds ISO 9001 for manufacturing quality and ISO 13485 if the device is for medical use. The product itself must have CE marking for the European market or UL/ETL certification for North America. Ensure the unit features over-temperature alarms, independent temperature limiters, and automatic power-off functions when the door is opened to protect both the user and the samples.
What capacity and configuration options are best for scaling research operations?
For high-throughput needs, look for stackable designs (up to 3 units) to save floor space. The platform size and universal spring racks are critical; ensure the unit can accommodate various vessel types, from 10ml tubes to 5L Erlenmeyer flasks. Suppliers offering interchangeable platforms provide the highest economic feasibility for labs with evolving project requirements.
What role does digital integration play in modern incubator shaker procurement?
Top-tier models should feature LCD touchscreens and programmable controllers for multi-step cycles. For data integrity and compliance (such as FDA 21 CFR Part 11), prioritize units with USB data logging, Ethernet connectivity, or RS485 interfaces for remote monitoring and automated record-keeping.
Cross-Border Procurement & Risk Management for Lab Equipment
How can I mitigate the risk of damage during international transit?
Incubator shakers contain sensitive compressors and drive shafts. Insist on seaworthy wooden crate packaging with internal shock-absorption foam. Request the supplier to install 'TiltWatch' or 'ShockWatch' indicators on the exterior to monitor handling. For high-value units, CIF (Cost, Insurance, and Freight) terms are recommended to ensure the cargo is fully insured against transit damage.
What strategies should be used when negotiating with specialized equipment suppliers?
Focus on the Total Cost of Ownership (TCO) rather than just the unit price. Negotiate for an extended warranty (24-36 months) and the inclusion of critical spare parts (e.g., drive belts, sensors) in the initial shipment. On platforms like Made-in-China.com, look for 'Audited Suppliers' to verify their factory capacity and R&D strength before discussing bulk discounts, which typically range from 10-20% for orders exceeding 5 units.
What are the essential precautions for customs clearance of scientific instruments?
Ensure the supplier provides an accurate HS Code (typically 8419.89) and a detailed Commercial Invoice. Be aware of refrigerant regulations; if the unit uses a cooling system, confirm the refrigerant (e.g., R134a) complies with the destination country's environmental laws. Lack of proper Declaration of Conformity can lead to costly port delays or seizures.
How is after-sales technical support handled across borders?
Before finalizing the purchase, confirm the availability of video technical support and English-language service manuals. Ask if the supplier can provide IQ/OQ/PQ (Installation, Operational, and Performance Qualification) documentation templates. Reliable suppliers on Made-in-China.com often provide remote diagnostic services to help local technicians resolve issues without returning the unit to the factory.





























