SourcingAI

isolator

I have found results from80000+products and30000+suppliers aboutisolator

Commonly used:
US$
Customization Available
Sample Available
Manufacturer First
Product attributes:
Type: Low-voltage
Type: High-voltage
Structure: Single-column Disconnector
Operation: Electric
Grounding Mode: Not Grounding
Movement Mode: Plug-in Type
Grounding: Single Ground
Series: Four
Run: Plug-In
Switching Mode: Double-Throw Type
Structure of Operating: Electric
Certification: ISO
Application: Industrial
Control Mode: Remote Control
Usage: Fragrance
Noise: 20-40db
Installation: Outdoor High-voltage
Number of Poles: Three Pole
Common Model: SR
Structure: Double-column Disconnector
Structure: Three-column Disconnector
Operation: Manual
Grounding Mode: Grounding
Movement Mode: Oscillating Type
Vertical Rotary Type
Horizontal Rotary Type
Grounding: Double Ground
Grounding: Un Grounded
Series: Single-Stage
Series: Three
Series: Two
Turn the Horizontal
Run: Vertical Rotation
Switching Mode: Single Throw-in
Structure of Operating: Manual
Structure of Operating: Pneumatic
Certification: RoHS
Certification: CE
Certification: ISO9001
Certification: GS
Certification: IS9001
Certification: ISO9002
Certification: ISO2000
Application: Commercial
Control Mode: Touch
Control Mode: Button
Usage: Dust Removal
Usage: Smoke Removal
Adding Negative Ion
Usage: Humidification
Usage: Formaldehyde Formaldehyde
Usage: Adding Oxygen
Usage: Sterilization
Noise: >100db
Noise: 60-70db
Noise: 40-60db
Noise: 70-90db
Installation: Indoor High-voltage
Number of Poles: Unipolar
Common Model: DR
Common Model: CR

Sourcing guidance for Isolator

How to choose the right type of Isolator based on application scenarios?

Selecting an isolator depends heavily on the industry. For electrical power systems, you must prioritize high-voltage porcelain or composite insulators that prevent current leakage. In biopharmaceutical or laboratory settings, you should focus on aseptic containment isolators (glove boxes) that maintain a Grade A air quality environment. For industrial vibration control, look for rubber or spring vibration isolators with specific load-bearing capacities and damping coefficients to protect sensitive machinery.

What are the key technical specifications and compliance standards for electrical isolators?

Buyers must ensure products comply with IEC 60660 for indoor post insulators or IEC 61109 for composite types. Key metrics include Rated Voltage (kV), Creepage Distance, and Mechanical Cantilever Strength. For the North American market, ANSI standards are mandatory. Always request Type Test Reports from the supplier to verify performance under extreme weather or electrical surge conditions.

What factors determine the quality and durability of chemical/biological isolators?

The integrity of the HEPA/ULPA filtration system is paramount, requiring a 99.999% efficiency rating. The enclosure should be constructed from 316L stainless steel for superior corrosion resistance against decontaminating agents like Vaporized Hydrogen Peroxide (VHP). Ensure the unit features automated leak testing and complies with ISO 14644-7 standards for contained enclosures.

How can I evaluate the cost-efficiency of isolator procurement?

Do not just look at the unit price; calculate the Total Cost of Ownership (TCO). For electrical isolators, composite materials may have a higher upfront cost but offer lower maintenance and cleaning expenses compared to porcelain. For pharmaceutical isolators, prioritize suppliers on Made-in-China.com who offer modular designs, which allow for easier upgrades and lower shipping volumes through CKD (Completely Knocked Down) delivery.

Cross-Border Purchasing Considerations for Isolators

What are the common risks when importing isolators internationally?

The primary risks include physical damage during transit (especially for fragile porcelain or glass components) and non-compliance with local grid or safety codes. To mitigate this, insist on seaworthy reinforced packaging and use third-party inspection services (like SGS or Intertek) to verify specifications before the balance payment is made.

How should I negotiate with Chinese isolator manufacturers?

Focus on technical transparency. Ask for material mill certificates and raw material sourcing details. For bulk orders, negotiate a staggered payment schedule (e.g., 30% deposit, 70% after inspection but before shipment). Mention that you are looking for a long-term strategic partner on Made-in-China.com to secure better after-sales technical support and spare parts availability.

What are the logistics and shipping precautions for heavy or sensitive isolators?

For large-scale industrial isolators, use FOB (Free On Board) terms to maintain control over the shipping line and costs. Ensure the supplier provides a detailed packing list and HS Code classification (typically under Chapter 85 for electrical or Chapter 84/90 for lab equipment) to avoid customs delays or incorrect duty applications. For high-precision lab isolators, specify the use of shock-sensor stickers on the crates to monitor handling during sea freight.

How can I ensure transaction security during the sourcing process?

Always conduct transactions through secured payment channels provided by reputable platforms like Made-in-China.com. Utilize their Audit Supplier reports to check the manufacturer's business license, production capacity, and export history. Avoid direct transfers to private bank accounts and always keep all technical agreements and quality benchmarks documented within the formal purchase contract.

Related queries